MRI Artifact Correction due to Unknown Respiratory Motion

미지 호흡운동에 의한 MRI 아티팩트의 수정

  • 김응규 (한밭대학교 정보통신ㆍ컴퓨터공학부)
  • Published : 2004.09.01

Abstract

In this study, an improved post-processing technique for correcting MRI artifact due to the unknown respiratory motion in the imaging plane is presented. Respiratory motion is modeled by a two-Dimensional linear expending-shrinking movement. Assuming that the body tissues are incompressible fluid like materials, the proton density per unit volume of the imaging object is kept constant. According to the introduced model, respiratory motion imposes phase error, non-uniform sampling and amplitude modulation distortions on the acquired MRI data. When the motion parameters are known or can be estimatead a reconstruction algorithm based on biliner superposition method was used to correct the MRI artifact. In the case of motion parameters are unknown, first, the spectrum shift method is applied to find the respiratory fluctuation function, x directional expansion coefficient and x directional expansion center. Next, y directional expansion coefficient and y directional expansion center are estimated by using the minimum energy method. Finally, the validity of this proposed method is shown to be effective by using the simulated motion images.

본 연구에서는 화상평면내 미지 호흡운동에 의한 MRI 아티팩트를 수정하기 위한 개선된 후처리 기법을 제안한다. 호흡운동은 2차원의 선형확대축소 운동으로 모델화 된다 신체조직을 비압축성 유체모양의 물질로 가정할 때 촬상 대상물체에 대한 단위체적당 푸로톤 밀도는 일정하다고 가정한다. 적용한 모델에 의하면 호흡운동은 위상오차와 불균일 표본화 및 진폭변조왜를 MRI 데이터에 부여한다. 운동파라메타가 알려져 있거나 추정가능하다고 할 때 양선형 중첩법에 기초한 재구성 알고리즘이 MRI 아티팩트를 수정하기 위해 사용된다. 운동 파라메타가 미지인 경우 스펙트럼 이동법을 적용해서 호흡변동함수와 x 방향 확대계수 및 x 방향 확대중심을 추정한다. 다음으로 에너지 최소법을 이용해서 y 방향 확대계수 및 y 방향 확대중심을 추정한다. 최종적으로 시뮬레이션된 체동화상을 통해서 제안한 본 방법의 유효성을 확인한다.

Keywords

References

  1. Z. Cho, J. P. Jones and M. Singh, Foundations of Medical Imaging, New York, John Wiley, pp. 237-267, 1993
  2. 김함겸, 박재성, 이혜경, 김대호, 영상진단학, 대학서림, pp.55-74, 1997
  3. 이성우, 은충기, 문치웅, 박수성, 초기 자기 공명 영상학, 여문각, pp.53-61, 1998
  4. 김응규, '위상 엔코딩 방향의 체동에 의한 MRI 아티팩트의 제거', 1998년도 한국정보과학회 가을학술발표논문집, 제25권 2호, pp. 432-434, 1998
  5. 김응규, 권영도, '촬상단면내의 MRI 체동 아티팩트의 제거', 1999년도 대한전자공학회 하계종합학술대회 논문집, 제22권 제1호, pp. 631-634, 1999
  6. 김응규, MRI에 있어서 체동 아티팩트의 제거, 대한전자공학회논문지, 제37권-SP편, 제3호, pp. 70-78, 2005. 5
  7. Eung-Kyeu Kim et al, 'Cancellation of MRI Motion Artifact in Image Plane', Proceeding of The 2002 Society, IEEE Instrumentation and Measurement Technology Anchorage Alaska, USA, 12 May 2002 https://doi.org/10.1109/IMTC.2002.1006862
  8. ML. Wood, MJ. Shivzi and PL. Stanchev, 'Planar Motion Correction with use of k-space data acquired in Fourier MR imaging', Journal of MRI, Vol. 5, pp. 57-64, 1995 https://doi.org/10.1002/jmri.1880050113
  9. M. Hedley and H. Yan, 'Suppression of Slice Selection Axis Motion Artifact in MRI,' IEEE Trans. Med. Imaging, Vol.11, No.2, pp.233-237, 1992 https://doi.org/10.1109/42.141647
  10. H. Yan and JC. Gore, 'An efficient algorithm for MRI image reconstruction without low spatial frequencies,' IEEE Trans. Med. Imaging, Vol.9, No.2, pp.30-36, 1992 https://doi.org/10.1109/42.56343
  11. EM. Haacke, JL. Patrick, DM. Balkely et al, 'Correction for motion artifacts based on a linear expansion model', The fourth annual S.M.R.M. Conference, London, Aug. 1985
  12. HW. Korin, F. Farzaneh, RC. Wright et al, 'Compensation for effects of linear motion in MR imaging', Magnetic Resonance in Med., Vol. 12, pp. 99-113, 1989 https://doi.org/10.1002/mrm.1910120113
  13. ML. Wood and R. M. Henkelman, 'Suppression of respiratory motion artifacts in magnetic resonance imaging', Medical Physics, Vol. 13, No. 6, pp. 794-805, 1986 https://doi.org/10.1118/1.595851
  14. E. Atalar and L. Onural, 'A respiratory motion artifact reduction method in magnetic resonance imaging of the chest', IEEE Trans. Medical Imaging, Vo. 10, No. 1, pp. 11-24, 1991 https://doi.org/10.1109/42.75607
  15. EM. Haacke and GW. Lenz, 'Improving MR image quality in the presence of motion by using rephasing gradients', AJR, Vol. 148, pp. 1251-1258, Jun. 1987 https://doi.org/10.2214/ajr.148.6.1251
  16. JK. Reik, AM. Tekalp, WE. Smith et al, 'Out-of-plane motion compensation in multislice spinecho MRI', IEEE Trans. Med. Imag., Vol. 14, pp. 464-470, 1995 https://doi.org/10.1109/42.414611
  17. R. L. Ehman and J. P. Felmlee, 'Adaptive technique for high-definition MR imaging of moving structures,' Radiology, Vol. 173, pp. 255-263, 1989 https://doi.org/10.1148/radiology.173.1.2781017
  18. J. P. Felmlee, R. L. Ehman, S. J. Riederer and H. W. Korin, 'Adaptive motion compensation in MR imaging without use of navigator echoes,' Radiology, Vol. 179, pp. 139-142, 1991
  19. M. Hedley, H. Yan and D. Rosenfeld, 'Motion artifact correction in MRI using generalized projections', IEEE Trans. Med. Imaging, Vol. 10, No. 1, pp.40-46, 1991 https://doi.org/10.1109/42.75609
  20. M. Hedley, H. Yan and D. Rosenfeld, 'An improved algorithm for 2-D translational motion artifact correction', IEEE Trans. Med. Imaging, Vol. 10, No. 4, pp. 548-553, 1991 https://doi.org/10.1109/42.108589
  21. 김응규, '회전운동에 기인한 MRI 아티팩트의 제거', 한밭대학교 논문집, 제19권, pp. 303-314, 2002. 12
  22. 김응규, 이수종, 김규헌, '3차원 강체운동에 의한 MRI 아티팩트의 제거', 한국신호처리시스템학회 추계학술대회논문집, 제4권 1호, pp. 58-61, 2003. 6
  23. J. E. Dennisr and R. Schnabel, Numerical Methods for Unconstrained Optimization and Nonlinear Equations, New Jersy, Prentice-Hall, 1993
  24. D. J. Nishimura, Introduction to Magnetic Resonance Imaging, textbook EE 369B, Stanford University Press, Stanford, CA, pp.156-167, 1994
  25. P. E. Gill, W. Murray, M. H. Wright, Practical Optimization, London, Academic, pp.83-153, 1981
  26. J. P. Felmlee, R. L. Ehman and S. J. Riederer, 'Adaptive motion compensation in MR imaging without use of navigator echoes', Radiology, Vol.179, pp.139-142, 1991 https://doi.org/10.1148/radiology.179.1.2006264