Spectrophotometric Determination of Nizatidine and Ranitidine Through Charge Transfer Complex Formation

  • Walash, M. (Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University.) ;
  • Din, M.-Sharaf-EI (Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University) ;
  • Metwalli, M.E.S. (Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University) ;
  • RedaShabana, M. (Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University)
  • 발행 : 2004.07.01

초록

Two Spectrophotometric procedures are presented for the determination of two commonly used H2-receptor antagonists, nizatidine (I) and ranitidine hydrochloride (II). The methods are based mainly on charge transfer complexation reaction of these drugs with either ${\rho}-chloranilic$ acid (${\rho}-CA$) or 2, 3 dichloro-5, 6-dicyanoquinone (DDQ). The produced colored products are quantified spectrophotometrically at 515 and 467 nm in chloranilic acid and 000 methods, respectively. The molar ratios for the reaction products and the optimum assay conditions were studied. The methods determine the cited drugs in concentration ranges of 20-200 and $20-160\;\mu\textrm{g}/mL$ for nizatidine and ranges of 20-240 and $20-140\;\mu\textrm{g}/mL$ for ranitidine with chloranilic acid and DDQ methods, respectively. A more detailed investigation of the complexes formed was made with respect to their composition, association constant, molar absorptivity and free energy change. The proposed procedures were successfully utilized in the determination of the drugs in pharmaceutical preparations. The standard addition method was applied by adding nizatidine and ranitidine to the previously analyzed tablets or capsules. The recovery of each drug was calculated by comparing the concentration obtained from the spiked mixtures with those of the pure drug. The results of analysis of commercial tablets and the recovery study (standard addition method) of the cited drugs suggested that there is no interference from any excipients, which are present in tablets or capsules. Statistical comparison of the results was performed with regard to accuracy and precision using student's t-test and F-ratio at 95% confidence level. There is no significant difference between the reported and proposed methods with regard to accuracy and precision.

키워드

참고문헌

  1. Abdel Hamid, M. E, Abdel Salam,M., Mahrous, M. S., and Abdel-Khalek, M. M., Utility of 7,7,8,8-tetracyanoqui-nodimethan and ${\rho}$-chloranilic acid in the qualitative and quantitative analysis of pentazocine. Talanta, 36, 1002-1004 (1985)
  2. Agarwal, S. P. and EISayed, M. A.-H., Unity of pi-acceptors in charge-transfer complexation of alkaloids: chloranilic acid as spectrophotometric titrant in non-aqueous media. Analyst 106, 1157-1162 (1981) https://doi.org/10.1039/an9810601157
  3. Al-Ghannam, S. and Belal, F., Spectrophotometric determi-nation of three anti-ulcer drugs through charge-transfer complexation. J. AOAC Int., 85,1003 (2002)
  4. Bourne, R. and Burgess, C., Effect of temperature on a multicomponent ultra-violet-spectrometric determination and the development of a temperature-independent assay procedure. Analyst, 120, 2075-2080 (1995) https://doi.org/10.1039/an9952002075
  5. Du, L. M., Fan, Z. F., and Zhang, R. F., Fluorescence spectrometric determination of f1eroxacin by charge-transfer reaction.Guang Pu Xue Yu Guang Pu Fen Xi, 23, 328-330 (2003)
  6. Guvener, B., Spectrophotometric determination method of ranitidine hydrochloride. Acta Pharm. Turc.,28, 35-37 (1986)
  7. Hassan, E. M. and Belal, F., Kinetic spectrophotometric determination of nizatidine and ranitidine in pharmaceutical preparations. J. Pharm. Biomed. Anal., 27, 31-38 (2002) https://doi.org/10.1016/S0731-7085(01)00473-3
  8. Kelani, K. M., Aziz, A. M., Hegazy, M. A, and Farrah, L. A., Determination of cimetidine, famotidine, and ranitidine hydrochloride in the presence of their sulfoxide derivatives in pure and dosage forms by high-performance thin- layer chromatography and scanning densitometry. J. AOAC Int., 85, 1015 (2002)
  9. Koricanac, Z., Jovanovic, T., and Stankovic, B., Determination of nizatidine in pharmaceutical formulations by potentiometric titration. Pharmazie, 50, 151-152 (1995)
  10. Martin, A., Physical Pharmacy, fourth ed, Lea & Febiger, Philadelphia, London, pp. 260-261 (1993)
  11. Martin, AN., Swarbrick, J., and Cammarata, A., Physical Pharmacy, third ed. Lee and Febiger, Philadelphia, pp. 344-346 (1983)
  12. Mathew, M., Das-Gupta, V., and Bethea,C., Quantitation of nizatidino in capsules using high-performance liquid chromatography. Drug Dev.lnd. Pharm.,19, 1497-1503 (1993) https://doi.org/10.3109/03639049309047187
  13. Miller, J. C. and Miller, J. N., Statistics for Analytical Chemistry, Wiley, New York (1984)
  14. Nagaralli, B. S., Melwanki, M. B., and Seetharamappa, J., Sensitive spectrophotometric methods for the determination of amoxycillin, ciprofloxacin and piroxicam in pure and pharmaceutical formulations. J. Pham. Biomed. Anal., 29, 859 (2002) https://doi.org/10.1016/S0731-7085(02)00210-8
  15. Nikolic, K., Stankovic, B., and Bogavac, M., Coulometric determination of ranitidine hydrochloride. Pharmazie, 50, 301-302 (1995)
  16. Rustum, A. M., Rapid and sensitive HPLC determination of ranitidine in plasma.I Application to pharmacokinetics study. J. Liq. Chromatogr., 11, 3447-3456 (1988) https://doi.org/10.1080/01483918808082267
  17. Walash, M. I., Belal, E, Ibrahim, E, Hefnawy, M., and Eid, M., Kinetic spectrophotometric method for the determination of nizatidine in pharmaceuticals. J. AOAC Int., 85, 1316 (2002)