Abstract

This paper presents a network based fire detection system using CAN, in order to evaluate feasibility of home automation protocol for smart home. In general, because a traditional fire detection system has an analog transmission method with 4-20mA current, it has several shortcomings such as weakness to noise. Hence, as an alternative to the traditional system, this paper presents the architecture of CAN based fire detection system and the design method of CAN communication network. Also, the performance of the suggested system is evaluated through an experimental testbed. Especially, CAN has several advantages such as low cost and easiness of implementation compared to Ethernet or ARCNET, which are low layer of BACNet. Therefore, if CAN is adopted as low layer of BACNet, the home automation system is implemented more effectively.

Keywords

References

  1. 박영칠, 'BACNet 의 필요성,' 설비저널, 제 29 권, 제 6 호, pp. 52-57, 2000
  2. R. Nunes, J. Delgado, 'An Architecture for a Home Automation System', IEEE International Conference on Electronics, Circuits and Systems, pp. 259-262,1998 https://doi.org/10.1109/ICECS.1998.813316
  3. K. S. Lee, K. C. Lee, S. Lee, K. T. Oh, S. M. Baek, Network Configuration Technique for home Appliances based on LnCP, IEEE Transactions on Consumer Electronics, vol.49, no. 2, pp. 367-374, 2003 https://doi.org/10.1109/TCE.2003.1209527
  4. K. Wacks, 'Home Systems Standards: Achievements and Challenges,' IEEE Communications Magazine, vol. 40, no. 4, pp. 152-159, 2002 https://doi.org/10.1109/35.995865
  5. 송원석, 홍승호, 송규동, 손장열, 'BACNet을 이용한 화재감지/모니터링 시스템 성능 평가,' 대한건축학회논문집, 제 18 권, 제 1 호, pp. 171-178, 2002
  6. N. Sriskanthan, F. Tan, and A. Karande, 'Bluetooth based home automation system,' Micropressors nad Microsystems, vol. 26, pp. 281-289, 2002 https://doi.org/10.1016/S0141-9331(02)00039-X
  7. D. Snoonian, 'Smart Buildings,' IEEE Spectrum, vol. 40, no. 8, pp. 18-23, 2003 https://doi.org/10.1109/MSPEC.2003.1222043
  8. T. C. Hooi, M. Singh, Y. K. Siah, and A. R. Ahmad, 'Building Low-Cost Intelligent Building Components with Controller Area Network (CAN) Bus,' Proceedings of IEEE Region 10 International Conference on Electrical and Electronic Technology, pp. 466-468, 2001 https://doi.org/10.1109/TENCON.2001.949636
  9. CiA DSP 416-1 V 1.0 part 1: CANopen application profile for building door control - General definitions and basic principles, 2003
  10. Road Vehicles-Interchange of Digital Information-Controller Area Network for High-Speed Communication, ISO 11898, 1994
  11. 이영실, 소방 설비 도해, 성안당, pp. 92-121, 1998
  12. D. T. Gottuk, M. J. Peatross, R. J. Roby, and C. L. Beyler, 'Advanced fire detection using multi-signature alarm algorithms,' Fire Safety Journal, vol. 37, no. 4, pp. 381-394, 2002 https://doi.org/10.1016/S0379-7112(01)00057-1
  13. 이홍철, 김태형, 황인주, '다센서 이용 호재 감지 및 추론 시스템 구축 연구(I),' 대한설비공학회 2003 년도 동계 학술 발표 대회 논문집, pp. 705-710, 2003
  14. K. Tindell and A. Burns, 'Guaranteed Message Latencies for Distributed Safety-Critical Hard Real Time Control Networks,' Technical Report YCS 94-229, Dept. Computer Science, Univ. of York, York, UK, 1994
  15. M. Ellims, S. Parker, and J. Zurlo, 'Design and Analysis of a Robust Real-Time Engine Control Network,' IEEE Micro, vol. 22, no. 4, pp. 20-27, 2002 https://doi.org/10.1109/MM.2002.1028472
  16. K. Tindell, H. Hansson, and A. Wellings, 'Analysing real-time communications: controller area network (CAN), Proceedings of IEEE Real-Time Systems Symposium, pp. 259-263, 1994 https://doi.org/10.1109/REAL.1994.342710
  17. W. Stalling, Local and Metropolitan Area Networks, 6th Ed. Macmillan Publishing Company, 2000
  18. NFPA, National Fire Alarm Code, 1996