A Study on the Suggestion of Thermal Comfort Range in Radiant Floor Ondol Heating System

  • Chung, Kwang-Seop (School of Architecture, Seoul National University of Technology)
  • 발행 : 2004.06.01

초록

The purpose of this study is to investigate the characteristics of thermal comfort index and to present the thermal comfort range through regression analyses and experiment in a radiant floor heating system laboratory. The results were compared to the comfort zone of ISO-7730, and the applicability of the thermal comfort index to a radiant floor heating system was studied. On comparing the sedentary posture on the floor to sitting on the chair, the comfort zone and the neutral point of comfort index showed different values. It is considered that the influence of conduction from floor to the human is sufficient. Moreover, we could find a correlation between the thermal sensation votes of subjects, and the comfort indexes were lower than those by calculation.

키워드

참고문헌

  1. Baik, Y. K., Sohn, J.Y. and Kim. S. Y., 1993, A study on the variation of entire thermal sensation according to the partial thermal sensation, Architectural Institute of Korea, Vol.7
  2. Lee, Y. C., Chung, K. S., Baik, Y. K. and Nam, D. H., 2001, A basic study on the developing thermal comfort index simulator and database in radiant floor heating system, Proceedings of Summer Annual Con-ference 2001, The Society of Air-condition-ing & Refrigerating Engineers in Korea(SAREK), Korea
  3. ASHRAE Standard 55-81, 1981, Thermal en-vironmental conditions for human occupancy
  4. ISO-7730, 1984, Moderate thermal environ-mental determination of the PMV and PPD indices and specification of conditions for thermal comfort (1st edition)