Micro-PIV Measurement of Water/Oil Two Phase Flow in a Y-Junction Microchannel

Y형 마이크로채널에서의 물/기름 2상 유동에 대한 Micro-PIV 측정

  • 윤상열 (부산대학교 대학원 기계공학과) ;
  • 고춘식 (부산대학교 대학원 기계공학) ;
  • 김경천 (부산대학교 기계공학부)
  • Published : 2004.06.01

Abstract

Y-junction microchannels are widely used as a flew mixer. Fluids are entered from two branch channels and merged together at a combined channel. In this study, we suggest a simple method to create the fluid digitization using flow instability phenomena. Two immiscible liquids (water/oil) are infused continuously to each Y-junction inlets. Because of the differences in fluid and flow properties at the interface, oil droplet is formed automatically followed by flow instability. In order to clarify the hydrodynamic aspects involved in oil droplet formation, a quantitative flow visualization study has performed. Highly resolved velocity vector fields are obtained by a micro-PIV technique, so that detail flow structures around the droplet are illustrated. In this study, fluorescent particles were mixed with water only for visualization of oil droplet and velocity field measurement in water flow.

Keywords

References

  1. Nisisako, T., Torii, T. and Higuchi, T., 2002, 'Preparation of Picoliter-Sized Reaction! Analysis Chambers for Droplet-Based Chemical and Biochemical Systems,' Micro Total Analysis Systems, Nara, Japan, 3-7 Nov, Vol. 1, pp. 362-367.
  2. Kawai, A., Futami, T., Kiriya, H., Katayama, K. and Nishizawa, K., 2002, 'Mass-Production System of Nearly Monodisperse Diameter GEL Particles Using Droplets Formation in a Microchannel,' Micro Total Analysis Systems, Japan, 3-7 Nov, Vol. 1, pp. 368-370
  3. Suh, Y. K. and Heo, H. S., 2003, 'A Numerical Study on Stirring Characteristics in a Microchannel with Various Arrangement of Blocks,' Trans. KSME B, Vol. 27, No. 7, pp. 901-908 https://doi.org/10.3795/KSME-B.2003.27.7.901
  4. Srinivasan, V., Pamula, V., Pollack, M. and Fair, R., 2003, 'A Digital Microfluidic Biosensor for Multianalyte Detection,' Proceedings of the IEEE 16th Annual International Conference on Micro Electro Mechanical Systems, pp. 327-330 https://doi.org/10.1109/MEMSYS.2003.1189752
  5. Paik, P. K., Pamula, V.. Pollack, M. G. and Fair, R. B., 2003, 'Electrowetting-Based Droplet Mixers for Microfluidic Systems,' Lab on a Chip, Vol. 3, pp. 28-33 https://doi.org/10.1039/b210825a
  6. Thorsen, T., Roberts, R. W., Arnold, F. H. and Quake, S. R., 2001, 'Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device,' Physical Review Letters, Vol. 86, pp. 4163-4166 https://doi.org/10.1103/PhysRevLett.86.4163
  7. Santiago, J. G., Wereley, S. T., Meinhart, C. D., Beebe, D. J. and Adrian, R. J., 1998, 'A Particle Image Velocimetry System for Microfluidics,' Experiments in Fluids, Vol. 25, No. 4, pp. 316-319 https://doi.org/10.1007/s003480050235
  8. Meinhart, C. D., Wereley, S. T. and Santiago, J. G, 1999, 'PIV Measurements of a Microchannel Flow,' Experiments in Fluids, Vol. 27, pp. 414-419 https://doi.org/10.1007/s003480050366
  9. Koutsiaris, A. G, Mathioulakis, D. S. and Tsangaris, S., 1999, 'Microscope PIV for Velocity-Field Measurement of Particle Suspentions Flowing Inside Glass Capillaried,' Meas. Sci & Tech., Vol. 10, pp. 1037-1046 https://doi.org/10.1088/0957-0233/10/11/311
  10. Olsen, M. G and Adrian, R. J., 2000, 'Out-of-Focus Effects on Particle Image Visibility and Correlation in Microscopic Particle Image Velocimetry,' Experiments in Fluids, Vol. 29, No. 7, pp. 166-174 https://doi.org/10.1007/s003480070018
  11. Experiments in Fluids v.29 no.7 Out-of-Focus Effects on Particle Image Visibility and Correlation in Microscopic Particle Image Velocimetry Olsen,M.G.;Adrian,R.J. https://doi.org/10.1007/s003480070018