Abstract
H$_2$SO$_4$ and citric acid were used as additives for the electrokinetic remediation experiment to increase removal efficiency of $^{137}$ Cs and $^{60}$ Co from the radioactive soil waste stored for more than 10 years. The average effluent velocity discharged from the elctrokinectic remediation experimental column was 2.0${\times}$10$^{-2}$ cm/min and the discharged soil wastewater volume for 10 days is 3.6 pore volume of the column. 97% of $^{60}$ Co in the column was decontaminated for 10 days of operation, while only 54% of $^{137}$ Cs was decontaminated. These results are considered that the absorption equilibrium coefficient of $^{137}$ Cs is higher than that of $^{60}$ Co. The predicted values of the residual concentration by the proposed mathematical model were well coincided with the experimental results within the experimental error range
10년 이상 된 방사능오염 토양에서 동전기적 방법에 의한 $^{137}$Cs과 $^{60}$Co의 제염효율을 높이기 위해 H$_2$SO$_4$과 시트르산을 첨가제로 사용했다. 동전기 토양복원 컬럼의 방출수 평균속도는 2.0${\times}$$10^{-2}$ cm/min이고, 10일 동안 방출된 토양폐액의 부피는 컬럼의 3.6 공극부피다. 10일간 $^{137}$Cs 의 제거효율이 54%에 불과한 반면에, $^{60}$Co는 97%나 제거되었다. 이것은 $^{137}$Cs의 흡착평형계수가 $^{60}$Co 보다 크기 때문이라고 생각된다. 본 연구에서 제시한 수학적 모델에 의한 컬럼 잔류 오염도는 실험 오차 범위에서 실험결과와 잘 일치하였다.