Numerical simulations of fluid mechanical interactions between two abdominal aortic branches

  • Kim, Taedong (Dept. of Environmental Eng., Andong National University) ;
  • Taewon Seo (School of Mechanical Eng., Andong National University, Dept. of Mechanical and Aeronautical Eng., University of California) ;
  • Abdul.I. Barakat (Dept. of Mechanical and Aeronautical Eng., University of California)
  • Published : 2004.06.01

Abstract

The purpose of the present study is to investigate fluid mechanical interactions between two major abdominal aortic branches under both steady and pulsatile flow conditions. Two model branching systems are considered: two branches emerging off the same side of the aorta (model 1) and two branches emerging off the opposite sides of the aorta (model 2). At higher Reynolds numbers, the velocity profiles within the branches in model 1 are M-shaped due to the strong skewness, while the loss of momentum in model 2 due to turning effects at the first branch leads to the absence of a reversed flow region at the entrance of the second branch. The wall shear stresses are considerably higher along the anterior wall of the abdominal aorta than along the posterior wall, opposite the celiac-superior mesenteric arteries. The wall shear stresses are higher in the immediate vicinity of the daughter branches. The peak wall shear stress in model 2 is considerably lower than that in the model 1. Although quantitative comparisons of our results with the physiological data have not been possible, our results provide useful information for the localization of early atherosclerotic lesions.

Keywords

References

  1. Biorheology v.34 Microcine-matographic studies of flow patterns in the excised rabbit aorta and its major branches Barakat,A.I.;T.Karino;C.K.Colton https://doi.org/10.1016/S0006-355X(97)00025-5
  2. Lab. Animal Science v.47 Measurement of flow rates through aortic branches in the anesthetized rabbits Barakat,A.I.;T.Karino;R.P.Marini;C.K.Colton
  3. J. of Biomechnaincs v.36 Hemodynamics simulation and identification of susceptible sites of atherosclerotic lesion formation in model abdominal aorta Buchanan,J.R.;C.Kleinstreuer;S.Hyun;G.A.Truskey https://doi.org/10.1016/S0021-9290(03)00088-5
  4. Biortheology v.35 Computational study of the effect of geometric and flow parameters on the steady flow field at the rabbit aorto-celiac bifurcation Cheer,A.Y.;H.A.Dwyer;A.I.Barakat;E.Sy;M.Bice https://doi.org/10.1016/S0006-355X(99)80020-1
  5. Biorheology v.16 Particle flow behavior in models of branching vessels: Ⅰ. vortices in 90° T-junctions Karino,T.;H.M.Herman;L.Goldsmith https://doi.org/10.3233/BIR-1979-16312
  6. J. of Biomechanical Eng. v.117 Numerical investigation and prediction of atherogenic sites in branching arteries Lei,M.;C.Kleinstreuer;G.A.Truskey
  7. Annals of Biomedical Eng.(under Review) Computational study of fluid mechanical disturbance induced by endovascular stents Seo,T.W.;L.G.Schachter;A.I.Barakat
  8. J. of Biomechanics v.33 Numerical study on the effect of secondary flow in the human aortic branches Shipkowitz,T.;V.G.J.Rodgers;L.J.Franzin;K.B.Chandran https://doi.org/10.1016/S0021-9290(99)00223-7
  9. Annals of Biomedical Eng. v.26 Finite element modeling of three-dimensional pulsatile flow in the abdominal aorta: relevance to atherosclerosis Taylor,C.A.;T.J.R.Hughes;C.K.Zarins https://doi.org/10.1114/1.140