DOI QR코드

DOI QR Code

Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique

구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용

  • Published : 2004.07.01

Abstract

In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

Keywords

References

  1. J. Sound Vib. v.49 no.2 Measurement of Structural Borne Wave Intensity, Part Ⅰ: Formulation of the Methods Pavic, G. https://doi.org/10.1016/0022-460X(76)90498-3
  2. J. Acoust. Soc. Am. v.47 Measurement of Power Flow in Uniform Beams and Plates Noiseux, D. U. https://doi.org/10.1121/1.1911472
  3. J. Acoust. Soc. Am. v.99 no.1 Measuring the Structural Intensity and Force Distribution in Plates Zhang, Y.;Adin Mann Ⅲ, J. https://doi.org/10.1121/1.414546
  4. J. Acoust. Soc. Am. v.99 no.1 Examples of Using Structural Intensity and the Force Distribution to Study Vibrating plates Zhang, Y.;Adin Mann Ⅲ, J. https://doi.org/10.1121/1.414547
  5. J. Acoust. Soc. Am. v.99 no.5 Error Evaluation of the Structural Intensity Measured with a Scanning Laser Doppler Vibrometer and a K-space Signal Processing Morikawa R.;Ueha, S. https://doi.org/10.1121/1.414878
  6. J. Sound Vib. v.256 no.1 Flexural Intensity Measurement on Finite Plates using Modal Spectrum Ideal Filtering Nejade, A.;Singh, R. https://doi.org/10.1006/jsvi.2001.4198
  7. J. Acoust. Soc. Am. v.97 no.6 Placing Small Constrained Layer Damping Patches on a Plate to Attain Global or Local Velocity Changes Spalding, A. B.;Mann Ⅲ, J. A. https://doi.org/10.1121/1.412444
  8. Ph.D. dissertation, Iowa State University An Experimental Model for Structural Intensity and Source Location Zhang, Y.
  9. J. Acoust. Soc. Am. v.101 no.4 Placing Constrained Layer Damping Patches using Reactive Shearing Structural Intensity Measurements Kruger, D. H.;Adin Mann Ⅲ, J.;Wiegandt, T. https://doi.org/10.1121/1.418243
  10. J. Acoust. Soc. Am. v.78 no.6 A Technique for Measurement of Structure-borne Intensity in Plates Williams, E. G.;Dardy, H. D.;Fink, R. G. https://doi.org/10.1121/1.392663
  11. 한국소음진동공학회논문집 v.9 no.1 능동적 점성 감쇠를 이용한 차량용 동적 흡진기의 모델링과 제어에 관한 연구 김대원;배준영