Abstract

The advantages of the Magnetic Fluid Linear Pump(MFLP) is that this device could Pump the non-conductive. non-magnetic liquid such as Insulin or blood because of the segregation structure of the magnetic fluid and pumping liquid. In this device. the sequential currents are needed to Produce pumping forces so that Pumping Forces and Pumping speed mainly depend on the current Patterns. The excessive forces at Pumping moment could cause the medical shock, and weak forces at intermediate moment could cause the back flow or the pumping liquid. So the ripples of the pumping forces need to be reduced for the medical application. In this research, the driving characteristics in the MFLP by operating current is analysed. The change of magnetic fluid surface according to the driving currents could be obtained be magneto-hydrodynamic analysis so that Pumping fortes could be computed by integration of the surface moving to the pumping direction at each moment. The actual MFLP with 13mm diameter was made and tested for experiments. The effects of driving current and frequency on the pumping forces and pumping speed were analyzed and compared with experimental measurements.

Keywords

References

  1. Yamaguchi, M, et al., 'Design investigation of linear motor for artificial heart driving', Trans. Institute of Elect. Eng. of Japan D-A Publication of Industry Applications Society, V. 117-D, N. 5, 1997
  2. Parker, RS. Doyle,FJ. Peppas NA, 'A model-based algorithm for blood glucose control in type Ⅰdiabetic patients', IEEE Trans. Mag., vol. 46, no. 2, pp. 148-157, January 1999 https://doi.org/10.1109/10.740877
  3. Matsuki H. et. al., 'Transcutaneous DC-DC converter for totally implantable artifical heart using synchronous rectifier,' IEEE Trans. Mag., vol. 32, no. 5, pp.5118-5120, September 1996 https://doi.org/10.1109/20.539509
  4. Wen, C. Li, M. Whitworth JA, 'Validation of transonic small animal flowmeter for measurement of cardiac output and regional blood flow in the rat', J. Cardiovascular Pharmacology, vol. 27, no. 4, April 1996 https://doi.org/10.1097/00005344-199604000-00005
  5. Verotta, D. 'A general solution for nonparametric control of a linear system using computer-controlled infusion pumps', IEEE Trans. Mag., vol. 46, no. 1, pp. 44-50, January 1999 https://doi.org/10.1109/10.736753
  6. Daoura MJ, Meldrum DR, 'Precise automated control of fluid volumes inside glass capillaries', J. Microelcetro-mechanical Systems, vol. 8, no. 1, pp. 71-77, March 1999 https://doi.org/10.1109/84.749405
  7. Melcher, James R., 'Continuum Electromechanics ', 1981
  8. Gwan Soo Park and Sang Ho Park, 'Design of Magnetic Fluid Linear Pump' International Magnetics Conference, Kyongju, Korea, May 18-21 1999 / IEEE Trans. Magn., Vol.35, No.5, pp. 4058-4060, Sep- tember 1999 https://doi.org/10.1109/20.800754
  9. Gwan Soo Park and Sang Ho Park, 'New Structure of the Magnetic Fluid Linear Pump', IEEE Intermag2000, 2000 IEEE International Magnetics Conference, pp. GS-02, Toronto, Canada, April 9-13, 2000 https://doi.org/10.1109/INTMAG.2000.872346
  10. Gwan Soo Park and Sang Ho Park, 'New Structure of the Magnetic Fluid Linear Pump', IEEE Trans. Magn., Vol.36, No.5, pp. 3709-3711, September 2000 https://doi.org/10.1109/20.908948
  11. G.S. Park, S.H. Park, 'Determination of the Curvature of the Magnetic Fluid under the External Forces', The 13th COMPUMAG Conference on the Computation of Electromagnetic Fields, Evain, France, July 2-5, 2001. / IEEE Trans. Magn., Vol.38, No.2, pp. 957-960, March 2002 https://doi.org/10.1109/20.996246