신고유치 해석 프로그램을 이용한 직류계통 축비틀림 진동 댐핑 제어기 설계

Design of HVDC System 550 Damping Controller Using Novel Eigenvalue Analysis Program

  • 발행 : 2004.03.01

초록

This paper presents the HVDC system modelling for analysis of subsynchronous oscillation and the design of the subsynchronous oscillation damping controller in HVDC system with the aid of novel eigenvalue analysis program. The HVDC system models include both the steady-state model for power flow calculation and the dynamic model for constructing the state matrix. The design procedures of the subsynchronous oscillation damping controller (SODC), which is integrated with PI controller at rectifier, consist of three steps:1) to identify the dominant torsional oscillation mode in the AC/DC system;2) to determine the parameters of the SODC for compensating the phase lagging due to the rectifier controller;3) to validate the control parameters and to determine the appropriate gain using a time-domain simulation program. The proposed design method has been tested against two AC/DC systems for validation.

키워드

참고문헌

  1. M. Bahrman, E. V. Larsen, R. J. Piwko, H. S. Patel, 'Experience with HVDC-Turbine-Generator Torsional Interaction at Square Butte', IEEE Transaction, Vol. PAS-99, No.3, May/June 1980 https://doi.org/10.1109/TPAS.1980.319726
  2. W. Shi, M. R. Iravani, 'Effect of HVDC Line Faults on Transient Torsional Torques of Turbine Generator Shafts', IEEE Transaction, Vol. PWRS-9, No.3, August 1994 https://doi.org/10.1109/59.336117
  3. A. H. Rahim, I. M. Amin, 'Stabilization of a High Voltage ACDC Power System ', IEEE Transaction, Vol. PAS-104, No. 11, November 1985 https://doi.org/10.1109/TPAS.1985.318938
  4. D. J. Kim, H. K. Nam, Y. H. Moon, 'A Novel Analysis Program of Small-Signal Stability of Power System Including Network Dynamics', ICEE 2002, Jeju
  5. D.J.Kim, H.K.Nam, Y.H.Moon, 'Universal SSR Small Signal Stability Analysis Program of Power Systems and its Applications to IEEE Benchmark Systems', KIEE, No.3 September 2003
  6. F. P. deMello, C. Concordia, 'Concepts of Synchronous Machine Stability as Affected by Excitation Control', IEEE Transaction, Vol. PAS-87, June, 1969, pp.316-329 https://doi.org/10.1109/TPAS.1969.292452
  7. E. V. Larsen, D. A. Swann, 'Applying Power System Stabilizers, Part I, II, and III', IEEE Transaction, Vol. PAS-100, No.6, June, 1981, pp.3017-3046 https://doi.org/10.1109/TPAS.1981.316411
  8. 김동준, 문영환, 허진, 신정훈, 김태균, 추진부, '다중-입력 PSS의 실제적인 튜닝방법과 대형전력시스템에의 적용', KIEE 51권 7호 2002년 7월
  9. B. K. Johnson, F. P. de Mello, J. M. Undrill, 'Comparing Fundamental Frequency and Differential Equation Representation of AC/DC, IEEE Transaction, Vol. PAS-101, No.9, Sep. 1982 https://doi.org/10.1109/TPAS.1982.317509
  10. E. W. Kimbark, Direct Current Transmission, Vol. I, 1971, John Wiley and Sons, Inc., USA
  11. R. Jotten, J. P. Bowles, G. Liss, C. J. B. Martin and E. Rumpf,' Control in HVDC Systems, The State of the Art, Part I: Two Terminal Systems,' CIGRE Paper 14-10, 1978
  12. G. K. Carter, C. E. Grund, H. H. Happ, R. V. Pohl, ' The Dynamics of AC/DC Systems with Controlled Multi-terminal HVDC Transmission', IEEE Transaction, Vol. PAS-96, No.2, March/April 1977 https://doi.org/10.1109/T-PAS.1977.32350
  13. HVDC System Control for Damping of Subsynchronous Oscillations, EL-2708, Oct. 1982 EPRI
  14. A. Ekstrom, G. Liss, 'A Refined HYDC Control System' IEEE Transaction, Vol. PAS-89 May/June 1970 pp 723-732 https://doi.org/10.1109/TPAS.1970.292626
  15. M. Takasaki, 'Study of ACIDC Power System Dynamic Instability and its Control',중앙전력연구소, T23
  16. 'First Benchmark Model for Computer Simulation of Subsynchronous resonance', by IEEE Subsynchronous Resonance Task Force of the Dynamic System Performance Working Group, Power System Engineering Committee, IEEE Transaction, Vol. PAS-95, 1977 https://doi.org/10.1109/T-PAS.1977.32485
  17. CIGRE WG 14-02: 'First Benchmark Model for HVDC Control Studies', Electa, April 1991, (135), pp. 55-75
  18. PSCAD/EMTDC ver 3.0.8, 2002