Abstract

A Miniature inertance pulse tube refrigerator was designed and tested with a 10 W compressor. Erperiments were carried out for different pulse tube length and inertance tube length. An adiabatic model which considered the pressure drop in the regenerator was used to analyze the performance of the pulse tube refrigerator. Among various design parameters which should be optimized, the pulse tube length and the inertance tube length were optimized. PdV work and several different loss mechanism were included in the analysis to simulate more accurately the physical phenomena in the pulse tube refrigerator. Nevertheless, the simulation program could not completely predict the porformance of the refrigerator. The possible reason for the difference of the optimal point between the simulation and the experiment was explained.

Keywords

References

  1. Superconductor & Cryoelectronics no.spring Pulse tubes gain foothol in cryocooler markets A.Bitterman;S.Broday
  2. Advances in Cryogenic Engineering v.43B Design of a 0.5 Watt Dual use long-life low-cost Pulse tube cooler D.T.Kho;A.S.Loc;S.W.K.Yuan;A.L.Johnson
  3. 공기조화 및 내동공학회, 동계학술발표회 논문집 77 K용 G-M형 외피스 맥도관 극저온 냉동기의 설계 및 성능 실험 남관우;정상권
  4. Stirling Cycle Engine Analysis Urieli
  5. Advances in Cryogenic Engineering v.43B Pulse tube coolers with an inertance tube Theoryk Modeling and Practice P.R.Roach;A.Kashani
  6. Fluid mechanics(Fourth edition) F.M.White
  7. Cryogenics v.34 no.7 Isothermal model of pulse tube refrigerator S.W.Zhu;Z.Q.Chen
  8. Plenum press Cryogenic Regenertive Heat Exchangers R.A.Ackermann
  9. Oxford university Press Cryogenic system R.F.Barron
  10. Cryocoolers v.12 Surface heat pumping loss in pulse tube refrigerator J.Jung;S.Jeong