Abstract
In this paper, implementation of active noise curtains using multiple channel adaptive filters is presented. The same numbers of single channel LMS algorithms as control loudspeakers is used instead of a multi-channel LMS algorithm to reduce the computational burden of adaptive filter algorithms. In general, a multi-channel LMS algorithm is usually used in active noise control system. but this algorithm has much more computational complexity. The single channel control techniques have less amount of DSP calculation, compared to multiple channel control techniques. A stabilizing procedure for adaptive IIR filters is also proposed to improve the stability of recursive LMS algorithms. Both experimental results of two control techniques using TMS320VC33 digital signal processor show the similar noise reduction, but the single channel control techniques are more efficient in practical active noise curtain applications
본 논문에서는 공간 외부의 원거리에 위치하는 소음원에 의하여, 창문 등을 통해 실내 공간에 소음이 전파될 때, 능동소음제어 기법을 이용하여 이를 제어하는 능동 방음막 (active noise curtain)을 구현하였다. 적응필터 알고리즘으로 다중채널 LMS 알고리즘을 사용하는 기법과 소음원이 원거리에 있을 때는 소음의 특성이 평면파에 가깝다는 가정 하에 제어용 스피커 수만큼의 단일채널 LMS 알고리즘을 사용하는 기법을 제시하였으며 적응필터의 안정도를 향상시키기 위하여 IIR 필터의 안정도를 향상시키는 안정화 기법을 제안하였다. TMS320VC33 DSP보드를 이용하여 제안된 기법을 정현파 소음 및 도로 소음에 대해 실험을 수행한 결과 MCLMS를 사용한 경우와 유사하거나 다소 나은 결과를 보였으며 제안한 기법이 실제 적용 시에는 제어용 스피커와 마이크로폰을 일체형으로 제작이 가능하여 하드웨어 실현에 유리하고 설치비도 절약되리라 예상된다.