DOI QR코드

DOI QR Code

Flowrate Integration Errors of Multi-path Ultrasonic Flowmeter using Weighting Factors

가중계수에 의한 다회선 초음파유량계의 유량적분오차

  • 이호준 ((주)창민테크 부설연구소) ;
  • 황상윤 ((주)창민테크 부설연구소) ;
  • 김경진 ((주)창민테크 부설연구소)
  • Published : 2004.10.01

Abstract

Multi-path ultrasonic flowrate measuring technology is being received much attentions from a variety of industrial fields to exactly measure the flowrate. Multi-path ultrasonic flowmeter has much advantage since it has no moving parts and little pressure loss. It offers good accuracy, repeatability, linearity and turn-down ratio can be over 1:50. The present study investigates flowrate integration errors using weighting factors. A theoretical flow model uses power law to describe a fully developed velocity profiles and wall roughness is changed. Gaussian, Chebyshev, and Tailor methods are used to integrate line-average velocities. The obtained results show that Chebyshev method in 2, 4-path arrangement and Gaussian method in 3, 5-path arrangement are not affected for wall roughness changes.

Keywords

References

  1. J. N. Som., 1994, 'Study on the calibration of the transit-time ultrasonic flowmeters ,' Jour Pure Appl. Ultrason, 17, pp. 114-120
  2. Pamela I Moore., Gregor J Brownn. and Brian P Stimpson., 2000, 'Ultrasonic transittime flowmeters modelled with theoretical velocity profiles ,' Meas. Sci. Technol. 11, pp. 1802-1811
  3. A. Calogirou., J. Boekhoven. and R.A.W.M. Henkes. , 2001, 'Effect of wall roughness changes on ultrasonic gas flowmeters ,' Flow measurement and Instrumentation 12, pp. 219-229
  4. Y. OHIMA., T. TAKAMIYA. and S. ITO., 2003, 'Flow Field Analysis for Ultrasonic Flow Meter, The 5th ASIAN COMPUTATION FLUID DYNAMICS, pp. 514-519
  5. B. Iooss., C. Lhuillier. and H. Jeanneau., 2002, 'Numerical simulation of transit-time ultrasonic flowmeters : Uncertainties due to flow profile and fluid turbulence ,' Ultrasonic 40, pp. 1009-1015
  6. Th. Wunderlich. and P. O. Brunn., 2000, 'A wall layer correction for ultrasound measurement in tube flow: Comparison between theory and experiment,' Flow measurement and Instrumentation 11, pp. 63-69
  7. M. Willatzen., 2003, 'Ultrasonic flowmeters: temperature gradient and transducer geometry effects ,' Ultrasonics 41, pp. 105-114
  8. C. N. PANNELL. , W. A. B. EVANS. and D. A. JACKSON., 1990, 'A new integration technique for flowmeters with chordal paths ,' Flow measurement and Instrumentation, Vol. 1, pp. 216-224 https://doi.org/10.1016/0955-5986(90)90016-Z
  9. 황상윤, 김경진, 박경암, 2002, '간접교정에 의한 다회선 초음파 유량계 UR-1000 불확도,' 유체기계 연구발 발표회 논문집, pp. 378-386
  10. 김주영, 김경진, 박성하, 2002, '대칭 및 비대칭 유동장에서 다회선 초음파 유량계의 유속분포 적분방법 평가' 유체기계 연구개발 발표회 논문집, pp. 370-377
  11. 김재형, 김희동, 이호준, 황상윤, 2003, '초음파 유량계를 통하는 기체유동의 CFD해 석,' 대한기계학술대회 논문집, pp. 999-1003
  12. 김희동 외., 2003, '쉽게 배우는 유체역학' 흥릉과학출판사, chapter.8 , pp. 415-416
  13. Schlichting., 1987, 'Boundary -Layer Theory,' Chapter xx

Cited by

  1. Error Characteristics of Clamp-on Ultrasonic Flowmeters Depending on Location of Sensors and Downstream Straight Run of Bent Pipe vol.35, pp.8, 2011, https://doi.org/10.3795/KSME-B.2011.35.8.861