DOI QR코드

DOI QR Code

Development of Cryogenic Pump Test Facility

극저온 펌프 성능시험설비의 개발

  • Published : 2004.08.01

Abstract

Cryogenic pump test facility (CPTF) is designed and developed in KARI. Hydraulic and cavitation performance of pump and inducer in cryogenic environment can be measured. Working fluid is liquid nitrogen and operating temperature is $-197^{\circ}C$. Run tank, catch tank of liquid nitrogen and their pressurizing tank has been built and remote tank pressure control system are installed. Maximum power of driving motor is 320 kW and its maximum speed is 32000rpm. Cryogenic fluids and lubricating systems are effectively separated that long test times are acquired. Therefore hydraulic and cavitation performance can be measured accurately and effectively. Pre-cooling test of the facility was successfully accomplished. This facility will contribute greatly to the development of turbopump for KSLV.

Keywords

References

  1. 채연석, 2003, 'KSR- III 성공과 우리나라의 우주개말 방향', 대덕과학포럼, pp. 23-33
  2. 홍순삼, 구현철, 차봉준, 김진한, 2003, '터보펌프 인듀서의 출구 유동 및 성능 특성', 유체기계저널, 제6권, 제4호, pp. 38-44
  3. 渡辺光男, 長谷川敏, 菊池正孝, 斉藤 降, 1983, ‘氣酸タ-ボポンプの起動試驗', 日本航空宇宙技術硏究所資料 519号, pp. 1-20

Cited by