참고문헌
- Wang, J. Electroanalytical Techniques in Clinical Chemistry andLaboratory Medicine; VCH: New York, 1988.
- Electrochemical Detection Techniques in the Applied Biosciences;Junter, G. A., Ed.; Ellis Horwood: Chichester, UK, 1998.
- Schulthess, P.; Ammann, D.; Krautler, B.; Caderas, C.; Stepanek,R.; Simon, W. Anal. Chem. 1985, 57, 1397. https://doi.org/10.1021/ac00284a048
- Stepanek, R.; Kraultler, B.; Schulthess, P.; Lindemann, B.;Ammann, D.; Simon, W. Anal. Chim. Acta 1986, 182, 83. https://doi.org/10.1016/S0003-2670(00)82439-3
- Amini, M. K.; Shahrokhian, S.; Tangestaninejad, S. Anal. Chem.1999, 71, 2502. https://doi.org/10.1021/ac9812633
- Meyerhoff, M. E.; Pranitis, D. M.; Yim, H. S.; Chaniotakis, N. A.;Park, S. B. Anal. Chim. Acta 1989, 217, 123. https://doi.org/10.1016/S0003-2670(00)80392-X
- Yuan, R.; Chai, Y.; Liu, D.; Gao, D.; Li, J.; Yu, R. Anal. Chem.1993, 65, 2572. https://doi.org/10.1021/ac00067a005
- Wuthier, U.; Pham, H. V.; Zand, R.; Welti, D.; Funck, R. J. J.;Bezegh, A.; Ammann, D.; Pretsch, E.; Simon, W. Anal. Chem.1984, 56, 535. https://doi.org/10.1021/ac00267a052
- Amini, M. K.; Shahrokhian, S.; Tangestaninejad, S. Anal. Chim.Acta 1999, 402, 137. https://doi.org/10.1016/S0003-2670(99)00549-8
- Badr, I. H. A.; Meyerhoff, M. E.; Hassan, S. S. M. Anal. Chem.1995, 67, 754.
- Nishizawa, S.; Bühlmann, P.; Xiao, K. P.; Umezawa, Y. Anal.Chim. Acta 1998, 35, 358.
- Li, Z. Q.; Liu, G. D.; Duan, L. M.; Shen, G. L.; Yu, R. Q. Anal.Chim. Acta 1999, 165, 382.
- Fibbioli, M.; Berger, M.; Schmidtchen, F.; Pretsch, E. Anal. Chem.2000, 72, 156. https://doi.org/10.1021/ac990696i
- Berrocal, M. J.; Cruz, A.; Badr, I. H. A.; Bachas, L. G. Anal.Chem. 2000, 72, 5295. https://doi.org/10.1021/ac000241p
- Morigi, M.; Scavetta, E.; Berrettoni, M.; Giorgetti, M.; Tonelli, D.Anal. Chim. Acta 2001, 439, 265. https://doi.org/10.1016/S0003-2670(01)01047-9
- Wizinger, R. Helv. Chem. Acta 1956, 5, 39.
- Shamsipur, M.; Yousefi, M.; Hosseini, M.; Ganjali, M. R. Anal.Chem. 2002, 74, 5538. https://doi.org/10.1021/ac0110451
- Ganjali, M. R.; Poursaberi, T.; Basiripour, F.; Salavati-Niasari, M.;Yousefi, M.; Shamsipur, M. Fresenius. J. Anal. Chem. 2001, 370,1091. https://doi.org/10.1007/s002160100915
- Ganjali, M. R.; Pourjavid, M. R.; Rezapour, M.; Haghgoo, S.Sens. Actuators B 2003, 89, 21. https://doi.org/10.1016/S0925-4005(02)00422-7
- Ganjali, M. R.; Poursaberi, T.; Hosseini, M.; Salavati-Niasari, M.;Yousefi, M.; Shamsipur, M. Anal. Sci. 2002, 18, 289. https://doi.org/10.2116/analsci.18.289
- Ganjali, M. R.; Naji, L.; Poursaberi, T.; Taghizadeh, M.; Pirelahi,H.; Yousefi, M.; Yeganeh-Faal, A.; Shamsipur, M. Talanta 2002,58, 359. https://doi.org/10.1016/S0039-9140(02)00289-8
- Lerchi, M.; Orsini, F.; Cimerman, Z.; Pretsch, E.; Chowdhury, D.A.; Kamata, S. Anal. Chem. 1996, 68, 3210. https://doi.org/10.1021/ac9601472
- Ammann, D.; Pretsch, E.; Simon, W.; Lindner, E.; Bezegh, A.;Pungor, E. Anal. Chim. Acta 1985, 171, 119. https://doi.org/10.1016/S0003-2670(00)84189-6
- Ammann, D.; Pretsch, E.; Simon, W.; Lindner, E.; Jeny, J.; Toth,K.; Pungor, E. Anal. Chem. 1991, 63, 1380. https://doi.org/10.1021/ac00014a009
- Gehring, P. M.; Morf, W. E.; Welti, M.; Pretsch, E.; Simon, W.Helv. Chin. Acta 1990, 73, 203. https://doi.org/10.1002/hlca.19900730124
- Umezawa, Y.; Umezawa, K.; Sato, H. Pure Appl. Chem. 1995, 67,507. https://doi.org/10.1351/pac199567030507
피인용 문헌
- Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade vol.8, pp.4, 2008, https://doi.org/10.3390/s8042331
- Carbon paste electrode modified with chromium thiopental for the potentiometric flow injection analysis of chromium (III) vol.94, pp.2, 2012, https://doi.org/10.1080/02772248.2011.647028
- Application of Tetra Cyclohexyl Tin(IV) as an Anionic Carrier for the Construction of a New Salicylate Membrane Sensor vol.54, pp.4, 2013, https://doi.org/10.1002/jccs.200700139
- Effect of the Nature of a Quaternary Ammonium Salt and the Addition of a Neutral Carrier on Analytical Characteristics of Sulfate-Selective Electrodes vol.73, pp.4, 2018, https://doi.org/10.1134/S1061934818040081
- Chemically Modified Carbon Paste Electrode for Determination of Sulfate Ion by Potentiometric Method vol.18, pp.16, 2006, https://doi.org/10.1002/elan.200503562
- Novel Triiodide PVC-Based Membrane Sensor Based on a Charge Transfer Complex of Iodine and Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone vol.26, pp.11, 2005, https://doi.org/10.5012/bkcs.2005.26.11.1738
- Zn2+ PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one vol.26, pp.4, 2005, https://doi.org/10.5012/bkcs.2005.26.4.579
- Highly Selective and Sensitive Copper(II) Membrane Sensors Based on 6-Methyl-4-(1-phenylmethylidene)amino-3-thioxo-1,2,4-triazin-5-one as a New Neutral Ionophore vol.17, pp.24, 2004, https://doi.org/10.1002/elan.200503356
- Sub-Micro Molar Monitoring of La3+ by a Novel Lanthanum PVC-Based Membrane Sensor Based on 3-Hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide vol.27, pp.10, 2004, https://doi.org/10.5012/bkcs.2006.27.10.1581
- A Highly Selective and Sensitive Calcium(II)-Selective PVC Membrane Based on Dimethyl 1-(4-Nitrobenzoyl)-8-oxo-2,8-dihydro-1H-pyrazolo[5,1-a]isoindole-2,3-dicarboxylate as a Novel Ionophore vol.27, pp.6, 2006, https://doi.org/10.5012/bkcs.2006.27.6.835
- Novel Tm(III) Membrane Sensor Based on 2,2'-Dianiline Disulfide and Its Application for the Fluoride Monitoring of Mouth Wash Preparations vol.27, pp.9, 2006, https://doi.org/10.5012/bkcs.2006.27.9.1418
- A Highly Selective and Sensitive Barium(II)-Selective PVC Membrane Based on Dimethyl 1-Acetyl-8-oxo-2,8-dihydro- 1H-pyra-zolo[5,1-a]isoindole-2,3-dicarboxylate vol.18, pp.9, 2006, https://doi.org/10.1002/elan.200503472
- Highly selective and sensitive chromium(III) membrane sensors based on 4-amino-3-hydrazino-6-methyl-1,2,4-triazin-5-one as a new neutral ionophore vol.119, pp.1, 2004, https://doi.org/10.1016/j.snb.2005.11.048
- Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor vol.28, pp.1, 2004, https://doi.org/10.5012/bkcs.2007.28.1.068
- Synthesis and Characterization of 2, 6-Di-(4'-Methyl Phenyl) Pyrylium Fluoroborate and Perchlorate in Single Step Salts Using 4'-Methyl Acetophenone vol.21, pp.1, 2012, https://doi.org/10.5369/jsst.2012.21.1.13
- Automated biological sulphate reduction: a review on mathematical models, monitoring and bioprocess control vol.39, pp.6, 2004, https://doi.org/10.1093/femsre/fuv033
- Preparation and properties of some ion selective membranes: A review vol.1182, pp.None, 2004, https://doi.org/10.1016/j.molstruc.2019.01.050