Study for Non-Destructive Testing of Polyethylene Electrofusion Joints - Ultrasonic Imaging test

폴리에틸렌 배관의 전기융착부 비파괴검사기술에 관한 연구

  • Kil Seong Hee (Dept. of Gas Safety R&D Center, Korea Gas Safety Corporation) ;
  • Kwon Jeong Rock (Dept. of Gas Safety R&D Center, Korea Gas Safety Corporation)
  • 길성희 (한국가스안전공사 가스안전시험연구원 제품연구실) ;
  • 권정락 (한국가스안전공사 가스안전시험연구원 제품연구실)
  • Published : 2004.09.01

Abstract

Electrofusion(EF) joints have been widely used as they are easy to fuse and suitable for high-quality joints for polyethylene(PE) pipes. This paper studies the cause of defects and classifies 5 types of defects. The defect detection technique for electrofusion joints of polyethylene piping is utilized by the ultrasonic phased array technique to obtain ultrasonic images of electrofusion joints. Test sample joints have been designed and fabricated using artificial defects which were made using paper. Finally, we studied the condition of electrofusion in the field and analyzed the main causes of defects. And we classified the defect types as local lack of fusion, sand inclusion, voids or air inclusion, short stab, excess penetration or excess bead.

본 연구에서는 PE배관 연결망에 있어 취약 부위인 두 개의 배관이 연결되는 부분 즉, 전기응착부에 대한 검사방법을 살펴보고 그 중에서도 위상배열 초음파를 이용한 비파괴 탐상방법에 대하여 고찰하였다. 그리고 정상 및 비정상 전기응착 시험편을 설계 및 제작하여 위상배열 초음파를 이용하여 PE배관 전기응착부에 대한 비파괴 탐상을 실시하였다. 마지막으로 현장에서 발생하는 전기융착 접합 실태를 조사한 후 원인을 분석하고 결함 유형을 분류하였다. 즉 융합 불량, 모래 섞임, 기포, 삽입 불량, 용입 과다의 5가지로 분류를 하였다.