Abstract
In this paper, the maximum von Mises stress and maximum displacement of the corner protection and secondary bottom structures have been analyzed using a finite element analysis technique. The design criterion of the comer protection is 1,500Pa for a normal nitrogen gas purging process at the beginning stage of start-up procedure. This pressure is very safe for the structure safety of the comer protection and secondary bottom plates. The corner protection and secondary bottom plates fabricated by
본 논문은 완전 밀폐방식의 LNG 저장탱크에서 코너 프로텍션과 2차 바닥판에 걸리는 최대 von Mises 응력과 최대 변위량을 유한요소법으로 해석하였다. LNG 저장탱크의 시운전 과정에서 질소가스로 탱크에 채워져 있는 공기를 퍼징하기 위해 코너 프로텍션에 공급할 수 있는 최대 가스압력은 1,500pa이다. 코너 프로텍션과 2차 바닥판에 공급된 가스압력 1,500pa에 의한 구조물 자체의 안전성은 대단히 높다. 그러나, 내부탱크와 같은