DOI QR코드

DOI QR Code

Designs and Fabrications of High-TC SQUID Magnetometer for Measuring a Weak Signal without Magnetic Shielding

비자기 차폐환경에서 미세자기신호 측정을 위한 고온 초전도 SQUID 자력계의 설계 및 제작

  • Yu, K.K. (Korea Research Institute of Standards and Science) ;
  • Kim, I.S. (Korea Research Institute of Standards and Science) ;
  • Park, Y.K. (Korea Research Institute of Standards and Science)
  • Published : 2004.03.31

Abstract

We have designed and fabricated the YBCO single layer directly-coupled SQUID magnetometers for the purpose of magnetocardiography in a magnetically disturbed environment. The SQUID magnetometers were designed three different types of pickup coil such as solid type, PL type I and PL type II for further stable fluxed-locked-loop operation without magnetic shielding. Magnetometer was fabricated with a single layer YBCO thin film deposited on STO(100) bicrystal substrate with misorientation angle of $30^{\circ}$. We have achieved a magnetic field noise BN of 30 fT/$Hz^{1/2}$ at 100 Hz, and less than 70 fT/$Hz^{1/2}$ at 1 Hz. The PL type II SQUIDs have exhibited the most stable fluxed-locked-loop operation in a magnetically unshielded environment.

Keywords

References

  1. H.J. Krause, GJ. Panaitov, and Yi Zhang, 'Conductivity Tomography for Non-destructive Evaluation Using Pulsed Eddy Current with HTS SQUID Magnetometer', IEEE Trans. Appl. Supercond.. vol. 13, pp. 215-218, 2003 https://doi.org/10.1109/TASC.2003.813688
  2. M. Muck. C. Welzel, A Farr, F. Schloz, and Waldemar Singer, 'Nondestructive Testing of Niobium Sheets for Superconducting Resonators'. IEEE Trans. Appl. Supereond., vol. 13, pp. 239-244. 2003 https://doi.org/10.1109/TASC.2003.813694
  3. D. Koelle, R. Kleiner. F. Ludwig. E. Dantsker. and J. Clarke. 'High Transition Temperature Superconducting Quantum Interference Devices', Rev. Modem Phys., vol. 71. no. 3. pp. 631-678, 1999 https://doi.org/10.1103/RevModPhys.71.631
  4. H.E. Hong. S.Y Hung, J.T. Jeng. S.H. Liao. S.C. Hsu. J.C. Hwang. and H.C. Yang. 'Biomagnetic Measurements with HTS SQUID Magnetometers in Moderate Shielded Environments'. IEEE Trans.Appl. Supercond., vol. 13, pp. 381-384, 2003 https://doi.org/10.1109/TASC.2003.813859
  5. A.P. Rijpma. Y. Seppenwoolde, H.J.M. ter Brake, and H. Rogalla. 'Application of SQUID Magnetometers in Fetal Magnetocardiography'. fnst. Phys. Conf. Ser., vol. 1, pp. 771-774, 1997
  6. F. Ludwig. A.B.M. Jansman, D. Drung, M.O. Lindstroem, S. Bechstein, J. Beyrer, J. Flokstra, and T. Schurig, "Optimization of Direct-coupled High-TC SQUID Magnetometers for Operation in Magnetically Unshielded Environment", IEEE Trans. Appl. Supercond.. vol. 11, pp. 1315-1318, 2001 https://doi.org/10.1109/77.919592
  7. S. Kuriki, H. Oyama, A Hayashi, S. Hirano, and T. Wahio. 'Development of a High-TC SQUID Based Magnetometer System for MCG Measurement'. IEICE Trans. Electron., vol. E85-C, no. 3, pp. 670-676, 2002
  8. P.J.M., and R.H. Koch, 'Magnetic Background Noise Cancellation in Real-world Environments'. Rev. Sci. lnstrum., vol. 71, pp. 1529-1533, 2000 https://doi.org/10.1063/1.1150490
  9. F. Ludwig, and D. Drung, 'Low-frequency Noise of Improved Direct-coupled High-TC Superconducting Quantum Interference Device Magnetometers in AC and DC Magnetic Fields', App/. Phys.. Lett., vol. 75, pp. 2821-2823, 1999 https://doi.org/10.1063/1.125161
  10. H.M. Cho, YT. Andresen, and J. Clarke, 'Low Frequency Noise in High Transition Temperature Superconducting Multiplayer Manetometers in Ambient Magnetic Fields', App/. Phys. Lett.• vol. 79, pp. 2438-2440, 2001 https://doi.org/10.1063/1.1410344
  11. M. Matsuda, T. Matsuura, K. Kato, H. Oyama, A Hayashi, and S. Kuriki, 'First Derivative High-TC SQUID Gradiometers with Narrow Structure from Single Layer YBCO Thin Film', IEICE Trans. Electron., vol. E85-C, no. 3, pp. 677-680, 2002