The Biological Effects of Calcium Phosphate Coated Implant for Osseointegration in Beagle Dogs

성견에 식립한 인산칼슘 피복 임플란트가 골조직 유착에 미치는 생물학적인 영향

  • Shim, Eon-Cheol (Department of Periodontology, College of Dentistry, Dan-Kook University) ;
  • Lim, Sung-Bin (Department of Periodontology, College of Dentistry, Dan-Kook University) ;
  • Chung, Chin-Hyung (Department of Periodontology, College of Dentistry, Dan-Kook University) ;
  • Kim, Jong-Yeo (Department of Oral Histology, College of Dentistry, Dan-Kook University)
  • 심언철 (단국대학교 치과대학 치주과학교실) ;
  • 임성빈 (단국대학교 치과대학 치주과학교실) ;
  • 정진형 (단국대학교 치과대학 치주과학교실) ;
  • 김종여 (단국대학교 치과대학 구강조직학교실)
  • Published : 2003.12.31

Abstract

The influence of calcium phosphate (Ca-P) coating on the bone response of titanium implants was investigated two types of titanium implants, i.e. as -machined ,as -machined with Ca-P coating, were prepared. The Ca-P coating produced by OCT Inc technique. These implants were inserted into the left and right femur of beagle dog, After implantation periods of 3 days, 1weeks, weeks, 4weeks, 8weeks, 12weeks. 24weeks, the bone-implant interface was evaluated histologically, histomorphometrically , and removal torque. Histological evaluation revealed no new bone formation around different implant materials after 2weeks of implantation. After 4 weeks, Ca-P coated implants showed a higher amount of bone contact than either of the non coated implants. After 12weeks, bone healing was almost completed. And implant were removed by reverse torque rotation with torque-measuring device. Mean torque values for 4weeks control were 2.375Kgf.cm and experimental were 2.725Kgf.cm. And mean torque values for 8weeks control were 1.25Kgf.cm and experimental were 1.0Kgf.cm On the basis of these findings, we concluded that deposition of a Ca-P coating on an implant has a beneficial effect on the bone response to this implant during the healing phase. Besides implant surface conditions the bone response is also determined by local implant site condition.

Keywords

References

  1. Maggiolo. : 'Le manual de I art du dentiste, Nancy,1807. in Lew. I.: progress in implant dentistry- an elevation'. J. Am. Dent. Assoc. 59:478-492,1959 https://doi.org/10.14219/jada.archive.1959.0200
  2. Linkow LI: Endoosseous oral implantology: A 7-year progress report. Dent Clin North Am. 14: 185-200, 1970
  3. Natiella JR, Armitage JE, Greene GW, Meenaghan HA: Current evaluationof dental implant. Council on dental materials and devices. J Am Dent Assoc. 84:1359-1373,1972
  4. Branemark PI, Breine U, Johasson B, Roylance PJ, Rockert H, Yoffey JM: Regeneration of bone marrow. A clinical and experimental study following removal of bonemarrow by curettage.Acta Anat. 59:1-46,1964 https://doi.org/10.1159/000142601
  5. Branemark PI: Introduction to osseointegration. In Branemark PI, Zarb GA, Albrektsson T(eds): Tissue integrated prosthesis. Osseointegration in clinical dentistry. Chicago, Quintessence Publishing Co., pp11-76,1985
  6. Albrektsson, T: Osseointegrated titanium implants. Acta Orthop Scand. 52:155-170,1981 https://doi.org/10.3109/17453678108991776
  7. Deporter DA, Watson PA, Pilliar RM: A histological assessment of the initial healing response adjacent to porous-surface, titanium alloy dental implant system in dogs. J Dent Res. 65:1064-1070, 1986 https://doi.org/10.1177/00220345860650080501
  8. Robers E: Bone tissue interface. J Dent Educ. 52: 804-809,1988
  9. Adell R, Lekholm U,Rockler B, Branemark PI: A 15-year study of Osseointergrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 10:387-416,1981 https://doi.org/10.1016/S0300-9785(81)80077-4
  10. Babbush CA, Kent JN, Misiekm DJ Titanium plasma sprayed(TPS) screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofac Surg. 44:274-282,1986 https://doi.org/10.1016/0278-2391(86)90078-9
  11. Albrektsson T, Dahl E, Enbom L: Osseointegrated oral implants. A swedish multicenter study of 8139 consecutively inserted nobelpharma implants. J Peridontol. 59:287-296, 1988 https://doi.org/10.1902/jop.1988.59.5.287
  12. Buser D, Weber HP, Lang NP: Tissue integration of a longitudinal study with ITI hollow-screw and hollow cylinder implants. Clin Oral Imp Res. 1: 33-40,1990 https://doi.org/10.1034/j.1600-0501.1990.010105.x
  13. Albrektsson, T., 'Intra-osseous anchourage of dental implants', J. Prostht. Dent., 50: 255-261,1983 https://doi.org/10.1016/0022-3913(83)90027-6
  14. Albrektsson, T., Jansson,T., and Lekholm, U. :'Osseointegrated dental implants, Dent. Clin. North. Am. 30: 151-174, 1986
  15. Steflik DE, Parr GR, Sisk AL, Lake FT et al. Osteoblast activity at the dental implant-bone interface: Transmission eclectron microscopic and high voltage electron microscopic observations. J periodontol .65:404-413,1994 https://doi.org/10.1902/jop.1994.65.5.404
  16. Kasemo B, Lausmaa J. Biomaterial and implant surfaces: A surface science approach. Int J Oral Maxillofacial Implants. 3:247-259,1988
  17. Zueiqat H, Howlett CR. Titanium substrata composition influences osteoblastic phenotype: Invitro study. J Biomed Mater Res. 47:360-366,1999 https://doi.org/10.1002/(SICI)1097-4636(19991205)47:3<360::AID-JBM10>3.0.CO;2-K
  18. Nanci A, Wuest JD, Peru L,Brunet P,Shama V,Z Alzal S, Mckee MD. Chemical modificationof titanium surface s for covalent attachment of biologicalmolecules. J Biomed Mater Res 40:324-335,1998 https://doi.org/10.1002/(SICI)1097-4636(199805)40:2<324::AID-JBM18>3.0.CO;2-L
  19. Taborelli M, Jobin M, Francois P,Vaudaux P, Tonerri Szmukler-Moncler S, Simpson P, Descouts P. Influence of surface treatments developed for oral implants on the physical and biologicalproperties of titanium. (1)Surface characterization. Clin Oral Impl Res. 8:208-216, 1997. https://doi.org/10.1034/j.1600-0501.1997.080307.x
  20. Buser D, Schenk RK, Steinmenn S, Fiorellini JP, Fox CH, Stich H, Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res. 1991;25:889-992 https://doi.org/10.1002/jbm.820250708
  21. Carlsson L, Rostlund T, Albrektsson B, Albrektsson T. Removal torques for polished and rough titanium implants. Int J Oral Maxillifac Implants. 1988;3:21-24
  22. Cook S, Baffes G, Palafox A, Wolfe M, Burgess A. Torsional stability of HA-coated and grit-blasted titanium dintal implants. J Oral Implantol. 18:354-358,1992
  23. Cook S, Kay J, Thomas K, Jarcho M interface mechanics and histology of titanium and hydroxy-lapatite-coated titanium for dental implant applications. Int J Oral Maxillofac Implants. 2;15-22.1987
  24. Cook S, Salkeid S, Gaisser D, Wagner W. The effect of surface macrotexture on the mechanical and histologic characteristics of hydroxylapatite-coated dental implants. J Oral Implantol. 14:288-294,1993
  25. Deporter DA, Watson PA, Pilliar RM, Chipman ML, Valiquette N, A histological comparison in the dog of porous-coated vs. threaded dental implants. J Dent Res. 69:1138-1145,1990 https://doi.org/10.1177/00220345900690050401
  26. Ericsson I, Johansson CB, Bystedt H, Norton MR, A histomorphometric evaluation of bone-tobone implant contact on machine-prepared and roughened titanium dental implants: A pilot study in the dog. Clin Oral Implants Res. 5:202-206,1994 https://doi.org/10.1034/j.1600-0501.1994.050402.x
  27. Gotfredsen K, WennerbergA, Johansson C, Skovgaard LT, Hjorting-Hansen E. Anchorage of TiO2-blasted HA-coated, and machined implants: An experimental study with rabbits. J Biomed Mater Res. 29:1223-1231,1995 https://doi.org/10.1002/jbm.820291009
  28. Gottlander M, Albrektsson T. Histomorphometric analyses of hydoxylapatite-coated and uncoated titanium implants. The importance of implant design. Clin Oral Implants Res. 3:71-76,1992 https://doi.org/10.1034/j.1600-0501.1992.030204.x
  29. Gottlander M, Albrektsson T. Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants. 1991:6:399-404
  30. Gottlander M, Albektsson T, Carlsson L. Ahistomorphometric study of unthreaded hydroxyapatite-coated and titanium-coated implants in rabbit bone Int J Oral Maxillofac Implants. 1992;7:485-490
  31. Jansen JA, van de Waerden J, Wolke J, de Groot K. Histologic evalustion of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants. J Biomed Mater Res. 1991;25:973-989 https://doi.org/10.1002/jbm.820250805
  32. Johansson CB, Albrektsson T. A removal torque and histomorphometric study of commercially pure niobium and titanuim implants in rabbit bone. Clin Oral Implants Res. 1991;2:24-29 https://doi.org/10.1034/j.1600-0501.1991.020103.x
  33. Matsui Y, Ohno K, Michi K, Yamagata K. Experimental study of high velocity flame-sprayed hydroxyapatite coated and noncoated implants. Int J Oral Maxillofac Implants. 1994;9:397-404
  34. Steflik D, McKinney R, Ultrastrustural comparisons of ceramic and titanium dental implants in vivo: A scanning electron microscopic study. J Biomed Mater Res. 1989;23:895-909
  35. Thomas K, Cook S. An evaluation of variables influencing implants fixation by direct bone apposition. J Biomed Mater Res. 1985;19:875-901 https://doi.org/10.1002/jbm.820190802
  36. Wennerberg A, Albrektsson T, Andersson B, Krol J. A histomorphmetric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Implants Res. 1995;6:24-30 https://doi.org/10.1034/j.1600-0501.1995.060103.x
  37. Gotfredsen K, Rostrup E, Hhorting-Hansson E, Stoltze K, Budtz-Jorgensen E. Histological and histomorphometrical evaluation of tissue reactions adjacent endosteal implants in monkeys. Clin Oral Implants Res. 1991;2:30-37 https://doi.org/10.1034/j.1600-0501.1991.020104.x
  38. Wilke HJ, Class L, Steinemann S. The influence of various titanuim surfaces on the interface shear strength between implants and bone. In: Heimke G, Soltesz U, Lee AJC, eds. Advances in Biomaterials. vol. 9, Clinical Implant Materials. Amsterdam: Elsevier Science Publishers B.V.; 1990:309-314
  39. Meffert R, Block M, Kent J. What is osseointegration? Int J Periodontics Restorative Dent. 1987;7(4):9-21
  40. Hahn H, Palich W: Preliminary evaluation of porous metal surfaced titanium for orthopedic implants. J Biomed Mater Res. 4:571-577,1970
  41. Steinmann SG, Eulenberger J,Mausli PA, Schroeder A: Adhesion of bone to titanium. Advance in Biomaterials Vol 6. Amsterdam, Biological and AJC Lee Elsevier Science Publishers,.pp409-414,1986
  42. Buser D, Schenk RK, Stinemann S, Fiorelini JP, Fox CH, Stich H: Influence of surface charateristics on bone integration titanium implants, A histomorphometric study in miniature pigs. J Biomed Mater Res. 25:880-902,1991
  43. Weinlaender M, Kenney EB, Lekobic V, Moy PK: Histomorphometry of bone apposition around tree types of osseous dental implants: Int J Oral Maxillofac Implants. 7:491-496,1992
  44. Albee FH, Morrison HF. Studies in bone growth-Triple calcium phosphate as a stimulus to osteo-genesis. Ann Surg, 1920;71:32-9
  45. Bhaskar SN, Cutright DE, Knapp MJ, Beasley JD, Perez B, Driskell TD. Tissue reaction to intrabony ceramic implants. Oral Surg Oral Med Oral Path. 1971;31:282 https://doi.org/10.1016/0030-4220(71)90086-7
  46. Jansen,J.A., van der Waerden,J.P.C.M., Wolke, J.G.C. & de Groot, K.(1991)Histologic evaluation of the osseous adaptation to titanium and hydroxyapatite-coated titanium implants. J Biomed Mater Res. 25: 973-989
  47. Dhert, W.J.A., Klein, C.P.A.T., Jansen,J.A., van der Velde, E.A., Vriesde, R.C., Rozing, P.M.& de Groot, K. (1993) A histological and histomorphometrical investigation of fluorapatite, magnesiumwhitlockite and hydroxyapatite plasmasprayed coatings in goats. J Biomed Mater Res. 27:127-138
  48. Caulier, H., van der Waerden,J.P.C.M., Paquay, Y.C.G.J., Wolke, J.G.C., Kalk, W., Naert, I. & Jansen, J.A. (1995) The effect of calciumphosphate (Ca-P) coatings on trabecular bone response: a histological study. J Biomed Mater Res. 29: 1061-1069
  49. Caulier, H., Vercaigne, S., Naert, I., van der Waerden, J.P.C.M., Wolke, J.G.C., Kalk, W.& Jansen,J.A. (1997a) The effect of Ca-P plasmasprayed coatings on the initial bone healing of oral implants; an experimental study in the goat. J Biomed Mater Res. 34:121-128
  50. Caulier, H.,van der Waerden, J.P.C.M., Wolke, J.G.C., Kalle, W., Naert, I. & Jansen,J.A. (1997b) A histological and histomorphometrical evaluation of the application of screw designed calciumphosphate(Ca-P) coated implants in the cancellous maxillary bone of the goat. J Biomed Mater Res. 35:19-30
  51. Ducheyne, P., Radin, S. & King, L.(1993) The effect of calcium phosphate ceramics composition and structure on in vitro behavior. I. Dissolution. J Biomed Mater Res. 27: 25-34
  52. Kangasniemi. I.M.O.., Verheyen, C.C.P.M., van der Velde, E.A. & de Groot, K.(1994) In vivo tensile testing of fluorapatite and hydroxylapatite plasma-sprayed coatings. J Biomed Mater Res. 28: 563-572
  53. Climens, J.A.M.(1995) Fluorapatite coatings for the osseointegration of orthopaedic implants. Thesis, University of Leiden, The Netherlands
  54. Klein, C.P.A.T., Wolke, .J.G.C., de Blieck-Hogervost, J.M.A. & de Groot, K.A. (1994a) Calcium phosphate plasma-sprayes coatings and their stability: An in vivo study. J Biomed Mater Res. 28:909-917
  55. Jansen, J.A., van der Waerden, J.P.C.M. & Wolke J.G.C.(1993a) Histologic investigation of the bioligical bahavior of different hydroxyapatite plasma-sprayed coatings in rabbits. J Biomed Mater Res. 27:603-610
  56. Cheang, P. & Khor, K.A. (1996) Addressing processing problems associated with plasma spraying of hydroxyapatite coatings. Biomaterials 17:537-544 https://doi.org/10.1016/0142-9612(96)82729-3
  57. Jansen, J.A., de Groot, K. (1993b) Application of magnetron sputtering for producing ceramic coatings on implant materials. Clinical Oral Implants Research 4:28-34 https://doi.org/10.1034/j.1600-0501.1993.040104.x
  58. Van Dijk, K., Schaeken, H.G. Wolke, J.G.C., Maree, C.H.M., Habraken, F.H.P.M., Verhoeven, J.& Jansen, J.A.(1995) Influence of discharge power level on the properties of hydroxyapatite films deposited on Ti6A14V with RF magnetron sputtering. J Biomed Mater Res. 29:269-276
  59. van dijk, K., Schaeken, H.G., Wolke,J.G.C & Jansen, J.A. (1996) Influence of annealing kemperature on RF magnetron sputtered calcium phosphate coatings. Biomaterials 17:405-410 https://doi.org/10.1016/0142-9612(96)89656-6
  60. Wolke,J.G.C.,van Dijk, K., Schaeken, H.G., de Groot, K. & Jansen. J.A. (1994) Study of the surface characteristics of magnetron-sputter calcium phosphate coatings. J Biomed Mater Res. 28: 1477-1484
  61. Wolke, J.G.C., van der Waerden, J.P.C.M., de Groot, K. & Jansen, J.A. (1997) Stability of radiofrequency magnetron sputtered calcium phosphate coatings under cyclically loaded condition. Biomaterial. 18:483-488
  62. Wolke,J.G.C. de Groot, K & Jansen, J.A. (1998) In vivo dissolution behavior of various RF magnetron sputtered Ca-P coating. J Biomed Mater Res. 39:524-530
  63. Hulshoff, J.E.G., Hayakawa, T., van Dijk, K., Leijdekkers-Govers, A.F.M., van der Waerden, J,P.C.M. & Jansen, J.A.(1997) Mechanical and histological evaluation of Ca-P plasma-spray and magnetron sputter-coated implant' in trabecular bone of the goat'. J Biomed Mater Res. 36:75-83
  64. Cheng Yang, Wuhan, The effect of calcium phosphate implant coating on osteoconduction. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2001;92:606-9
  65. Cotell CM. Pulsed laser deposition and processing of biocompatible hydoxylapatite thin films. Appl Surf Sci 1993;69:140-8 https://doi.org/10.1016/0169-4332(93)90495-W
  66. Cui FZ, Luo ZS, Feng QL. Highly adhesive hydroxyapatite coatings on titanium alloy formed by ion beam assisted deposition. J Mater Sei: Mater Med 1997;8:403-5
  67. Ducheyne P, Radin S, Heughebaert M, Heughebaert JC. Calcium phosphate ceramic coatings on porous titaniun: effect of structure and composition on edectrophoretic deposition, vacuum sintering and in vitro dissolution. Biomaterials 1990;11:244-54 https://doi.org/10.1016/0142-9612(90)90005-B
  68. Campbell AA, Fryxell GE, Linehau JC, Graff GL. Surface-in-duced mineralization: a new method for producing calcium phosphate coatings. J Biomed Mater Res 1996;32:111-8 https://doi.org/10.1002/(SICI)1097-4636(199609)32:1<111::AID-JBM13>3.0.CO;2-P
  69. Kim HM, Miyaji F, Kokubo T, Nakamura T. Bonding stregth of bonelike apatite layer on Ti metal substrate. J Biomed Mater Res (Appl Biomater) 1997;38:121-7 https://doi.org/10.1002/(SICI)1097-4636(199722)38:2<121::AID-JBM6>3.0.CO;2-S
  70. Wennerberg, A., Alberktsson, T. & Andersson, B. (1995a) Ananimal study of c.p, titanium screws with different surface topographies. J Mater Sci: Materials in Medicine 6:302-309
  71. Wennerberg, A., Alberktsson, T. Andersson, B & Krol, J.J. (1995b) A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clinical Oral Implants Research 6:24-30 https://doi.org/10.1034/j.1600-0501.1995.060103.x
  72. Wennerberg, A., Alberktsson, T., Johnansson, C. & Andersson, B. (1996a) Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effect of blasting material and surface topography. Biomaterials 17:15-22 https://doi.org/10.1016/0142-9612(96)80750-2
  73. Wennerberg, A., Alberktsson, T. & Lausmaa, J. (1996b) Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25-and 75-${\mu}m$-sized particles of Al203. J Biomed Mater Res. 30:251-260. https://doi.org/10.1002/(SICI)1097-4636(199602)30:2<251::AID-JBM16>3.0.CO;2-P
  74. Wong, M., Eulenberger. J., Schenk, R. & Hunziker, E. (1995) Effect of surface topology on the osseointegration of implant materials in trabecular bone. J Biomed Mater Res. 29(12):1567-1575
  75. Hayakawa T, Yoshinari M, Nemoto K, Wolke JGC, Jansen JA. Effect of surface roughness and calcium phosphate eating on the implant/bone response. Clin Oral Implants Res 11:296-304, 2000
  76. Vercaigne S, Wolke JGC, Naert Jansen JA. A histological evaluation of TiO2-gritblasted and Ca-P magnetron Sputter coated implants placed into the Trabecular bone of the goat: part2. Clin Oral Implants Res. 11:314-324, 2000
  77. Sennerby L, Thomesen P, Ericson LE: A morphologic and Biomechanic Comparison of Titanium implants in rabbit cortical and cancellous bone. Int. J Oral Maxillofac Implants 7:62-71, 1992