Lifetime estimation of a covered overhead line conductor

  • 투고 : 2002.11.11
  • 심사 : 2003.07.30
  • 발행 : 2003.08.25

초록

The paper presents results of studies concerning wind-induced aeolian vibration and fatigue of a 110 kV covered conductor overhead line. Self-damping measurement techniques are discussed: power method is found to be the most reliable technique. A method for compensating tension variations during the self-damping test is presented. Generally used empirical self-damping power models are enhanced and the different models are compared with each other. The Energy Balance Analysis (EBR) is used to calculate the aeolian vibration amplitudes, which thereafter are converted to bending stress for the calculation of conductor lifetime estimate. The results of EBA are compared with field measurements, Results indicate that adequate lifetime estimates are produced by EBA as well as field measurements. Generally the EBA gives more conservative lifetime expectancy. This is believed to result from the additional damping existing in true suspension structures not taken into account by EBA. Finally, the correctness of the line design is verified using Cigre's safe design tension approach.

키워드

참고문헌

  1. Cigre Study Committee 22-Working Group 01 (1989), "Report on aeolian vibration", Electra, (124), 41-77.
  2. Cigre Study Committee 22-Working Group 4 (1979), "Recommendations for the evaluation of the lifetime of transmission line conductors", Electra, (63), 103-145.
  3. Cigre Study Committee 22-Working Group 11 Task Force 2 (1995), "Guide to vibration measurements on overhead lines", Electra, (163), 125-137.
  4. Cigre Study Committee 22-Working Group 11 Task Force 1 (1998), "Modelling of aeolian vibration of single conductors: assessment of the technology", Electra, (181), 53-69.
  5. Cigre Study Committee 22-Working Group 11 Task Force 4 (1999), "Safe design tensions with respect to aeolian vibration. Part 1: Single unprotected conductors", Electra, (186), 53-67.
  6. Brika, D. and Laneville, A. (1996), "A laboratory investigation of the aeolian power imparted to a conductor using a flexible circular cylinder", IEEE Transactions on Power Delivery, 11(2), 1145-1152. https://doi.org/10.1109/61.489379
  7. Diana, G., Falco, M., Cigada, A., and Manenti, A. (2000), "On the measurement of overhead transmission lines conductor self-damping", IEEE Transactions on Power Delivery, 15(1), 285-292. https://doi.org/10.1109/61.847264
  8. European Committee for Standardisation (1995), "Eurocode 1 (ENV-1991-2-4): Basis of design and actions on structures - Part 2-4: Actions on structures - Wind actions".
  9. Kantola, K. (2002), "Aeolian vibrations in single overhead conductors", Technical report for NK Cables Ltd, Helsinki University of Technology, Finland.
  10. Leskinen, T. (1998), "Wind-induced transmission line conductor vibration: theory and measurements", Licentiate thesis, Lappeenranta University of Technology, Finland.
  11. Newland, D.E. (1989), An Introduction to Random Vibrations and Spectral Analysis, 2nd ed. Longman Scientific & Technical, Essex, England.
  12. Noiseux, D.U., Houle, S., and Beauchemin, R. (1986), "Study of effective aeolian wind power imparted to single conductor spans", CEA project 146 T 328.
  13. Noiseux, D.U., Hardy, C., and Houle, S. (1987), "Statistical methods applied to aeolian vibrations of overhead conductors", Journal of Sound and Vibration, 113(2), 245-255. https://doi.org/10.1016/S0022-460X(87)80213-4
  14. Press, W.H., Flannery, B.P., Teukolsky, S.A., and Vetterling, W.T. (1988), Numerical Recipes, Cambridge University Press, NY.
  15. Rawlins, C.B. (1998), "Model of power imparted by turbulent wind to vibrating conductor", Alcoa Conductor products company, Technical note no. 31.
  16. Rawlins, C.B. (2000), "The long span problem in the analysis of conductor vibration damping", IEEE Transactions on Power Delivery, 15(2), 770-776. https://doi.org/10.1109/61.853018