Analytical and experimental research on wind-induced vibration in high-rise buildings with tuned liquid column dampers

  • Liu, Ming-Yi (Department of Civil Engineering, National Central University) ;
  • Chiang, Wei-Ling (Department of Civil Engineering, National Central University) ;
  • Chu, Chia-Ren (Department of Civil Engineering, National Central University) ;
  • Lin, Shih-Sheng (Department of Civil Engineering, National Central University)
  • Received : 2000.10.31
  • Accepted : 2002.10.22
  • Published : 2003.02.25

Abstract

In recent years, high-strength, light-weight materials have been widely used in the construction of high-rise buildings. Such structures generally have flexible, low-damping characteristics. Consequently, wind-induced oscillation greatly affects the structural safety and the comfort of the building's occupants. In this research, wind tunnel experiments were carried out to study the wind-induced vibration of a building with a tuned liquid column damper (TLCD). Then, a model for predicting the aerodynamic response in the across-wind direction was generated. Finally, a computing procedure was developed for the analytical modeling of the structural oscillation in a building with a TLCD under the wind load. The model agrees substantially with the experimental results. Therefore, it may be used to accurately calculate the structural response. Results from this investigation show that the TLCD is more advantageous for reducing the across-wind vibration than the along-wind oscillation. When the across-wind aerodynamic effects are considered, the TLCD more effectively controls the aerodynamic response. Moreover, it is also more useful in suppressing the acceleration than the displacement in biaxial directions. As s result, TLCDs are effective devices for reducing the wind-induced vibration in buildings. Parametric studies have also been conducted to evaluate the effectiveness of the TLCD in suppressing the structural oscillation. This study may help engineers to more correctly predict the aerodynamic response of high-rise buildings as well as select the most appropriate TLCDs for reducing the structural vibration under the wind load. It may also improve the understanding of wind-structure interactions and wind resistant designs for high-rise buildings.

Keywords

Acknowledgement

Supported by : National Science Council (NSC) of Taiwan, R.O.C.

References

  1. Balendra, T., Wang, C.M. and Cheong, H.F. (1995), "Effectiveness of tuned liquid column dampers for vibration control of towers", Engineering Structures, 17(9), 668-675. https://doi.org/10.1016/0141-0296(95)00036-7
  2. Basu, R.I. and Vickery, B.J. (1983), "Across-wind vibrations of structures of circular cross-section. Part II. Development of a mathematical model for full-scale application", J. Wind Eng. Ind. Aerod., 12, 75-97. https://doi.org/10.1016/0167-6105(83)90081-8
  3. Cermak, J.E. and Isyumov, N. (1999). Wind tunnel studies of buildings and structures, ASCE Press, Virginia, U.S.A.
  4. Cheng, C.M., Lo, H.Y. and Lu, P.C. (1999), "Acrosswind responses of square shaped high-rise buildings with eccentricities", Proceedings of 10th International Conference on Wind Engineering, Copenhagen, Denmark, 631-636.
  5. Davenport, A.G. (1976). Vibration of structures induced by wind, Shock and Vibration Handbook, McGraw-Hill, Inc., New York, U.S.A.
  6. Gao, H. and Kwok, K.C.S. (1997), "Optimization of tuned liquid column dampers", Engineering Structures, 19(6), 476-486. https://doi.org/10.1016/S0141-0296(96)00099-5
  7. Hayashida, H., Mataki, Y. and Iwasa, Y. (1992), "Aerodynamic damping effects of tall building for a vortex induced vibration", J. Wind Eng. Ind. Aerod., 41-44, 1973-1983.
  8. Iwan, W.D. and Yang, I.M. (1972), "Application of statistical linearization technique to nonlinear multidegree-offreedom systems", Journal of Applied Mechanics, ASME, 39, 545-550. https://doi.org/10.1115/1.3422714
  9. Kanda, J. and Choi, H. (1992), "Correlating dynamic wind force components on 3-D cylinders", J. Wind Eng. Ind. Aerod., 41-44, 785-796.
  10. Kareem, A. (1984), "Model for predicting the acrosswind response of buildings", Engineering Structures, 6, 136- 141. https://doi.org/10.1016/0141-0296(84)90006-3
  11. Kareem, A. (1992), "Dynamics response of high-rise buildings to stochastic wind loads", J. Wind Eng. Ind. Aerod., 41-44, 1101-1112.
  12. Kawai, H. (1992), "Vortex induced vibration of tall buildings", J. Wind Eng. Ind. Aerod., 41-44, 117-128.
  13. Kolmogorov, A.N. (1941), "The local structure of turbulence in incompressible viscous fluid for very large Reynolds numbers", Dokl. Akad. Nauk, SSSR, 4, 299-319.
  14. Kwok, K.C.S. (1982), "Cross-wind response of tall buildings", Engineering Structures, 4, 256-262. https://doi.org/10.1016/0141-0296(82)90031-1
  15. Matsumoto, T. (1986), "On the across-wind oscillation of tall buildings", J. Wind Eng. Ind. Aerod., 24, 69-85. https://doi.org/10.1016/0167-6105(86)90073-5
  16. Mehta, K.C. and Marshall R.D. (1998), Guide to the use of the wind load provisions of ASCE 7-95, ASCE Press, Virginia, U.S.A.
  17. Ohkuma, T. and Kanaya, A. (1978), "On the correlation between the shape of rectangular cylinders and characteristics of fluctuating lifts on them", Proceedings of 5th Symposium on Wind Effects on Structures, Tokyo, Japan, 147-154 (in Japanese).
  18. Sakai, F., Takaeda, S. and Tamaki, T. (1989), "Tuned liquid column damper-new type device for suppression of building vibration", Proceedings of 1st International Conference on High-Rise Buildings, Nanjing, China, 926- 931.
  19. Samali, B., Kwok, K.C.S., Young, G. and Xu, Y.L. (1992), "Effectiveness of optimized tuned liquid column dampers in controlling vibration of tall buildings subject to strong ground motions", Proceedings of 2nd International Conference on High-Rise Buildings, Nanjing, China, 402-407.
  20. Sun, K., Cheong, H.F. and Balendra, T. (1993), "Effect of liquid dampers on along-wind response of structures", Proceedings of 3rd Asia-Pacific Symposium on Wind Engineering, Hong Kong, 835-840.
  21. Vickery, B.J. (1981), "Across-wind buffeting in a group of four in-line model chimneys", J. Wind Eng. Ind. Aerod., 8, 177-193. https://doi.org/10.1016/0167-6105(81)90017-9
  22. Vickery, B.J. and Basu, R.I. (1983), "Across-wind vibrations of structures of circular cross-section. Part I. Development of a mathematical model for two-dimensional conditions", J. Wind Eng. Ind. Aerod., 12, 49-73. https://doi.org/10.1016/0167-6105(83)90080-6
  23. Vickery, B.J. and Basu, R.I. (1984), "The response of reinforced concrete chimneys to vortex shedding", Engineering Structures, 6, 324-333. https://doi.org/10.1016/0141-0296(84)90030-0
  24. Vickery, B.J. (1995), "The response of chimneys and tower-like structures to wind loading", State of the Art Volume, 9th International Conference on Wind Engineering, New Delhi, India, 205-233.
  25. Won, A.Y.J., Pires, J.A., and Haroun, M.A. (1997), "Performance assessment of tuned liquid column dampers under random seismic loading", International Journal of Non-Linear Mechanics, 32(4), 745-758. https://doi.org/10.1016/S0020-7462(96)00118-7
  26. Xu, Y.L., Kwok, K.C.S. and Samali, B. (1992a), "The effect of tuned mass dampers and liquid dampers on cross-wind response of tall/slender structures", J. Wind Eng. Ind. Aerod., 40, 33-54. https://doi.org/10.1016/0167-6105(92)90519-G
  27. Xu, Y.L., Samali, B. and Kwok, K.C.S. (1992b), "Control of along-wind response of structures by mass and liquid dampers", J. Eng. Mechanics, ASCE, 118(1), 20-39. https://doi.org/10.1061/(ASCE)0733-9399(1992)118:1(20)

Cited by

  1. Active vibration control of an oscillator with two translational degrees of freedom using centrifugal forces created by two eccentrically rotating masses 2016, https://doi.org/10.1007/s40435-016-0280-8
  2. Numerical simulation of tuned liquid tank- structure systems through σ-transformation based fluid-structure coupled solver vol.23, pp.5, 2016, https://doi.org/10.12989/was.2016.23.5.421
  3. Stochastic optimal control of wind-excited tall buildings using semi-active MR-TLCDs vol.19, pp.3, 2004, https://doi.org/10.1016/j.probengmech.2004.02.010
  4. Magneto-rheological tuned liquid column dampers (MR-TLCDs) for vibration mitigation of tall buildings: modelling and analysis of open-loop control vol.83, pp.25-26, 2005, https://doi.org/10.1016/j.compstruc.2005.03.011
  5. Dynamic Parameter Identification of Secondary Mass Dampers Based on Full-Scale Tests vol.27, pp.3, 2012, https://doi.org/10.1111/j.1467-8667.2011.00740.x
  6. Wind-induced vibration of high-rise building with tuned mass damper including soil–structure interaction vol.96, pp.6-7, 2008, https://doi.org/10.1016/j.jweia.2007.06.034