DOI QR코드

DOI QR Code

Energy dissipation response of brick masonry under cyclic compressive loading

  • Senthivel, R. (Department of Civil Engineering, Indian Institute of Technology) ;
  • Sinha, S.N. (Department of Civil Engineering, Indian Institute of Technology)
  • Received : 2002.08.12
  • Accepted : 2003.04.16
  • Published : 2003.10.25

Abstract

Scaled brick masonry panels were tested under cyclic unialxial compression loading to evaluate its deformation characteristics. An envelope stress - strain curves, a common point curves and stability point curves were obtained for various cyclic test conditions. Loops of the stress-strain hysteresis were used to determine the energy dissipation for each cycle. Empirical expressions were proposed for the relations between energy dissipation and envelope and residual strains. These relations indicated that the decay of masonry strength starts at about two-third of peak stress.

Keywords

References

  1. Alshebani, M.M. and Sinha, S.N. (1999), "Energy dissipation of masonry under cyclic biaxial compression", Int. Conf. on Structures Under Shock and Impact - VI, University of Cambridge, London, 427-436.
  2. Atkinson, R.H. and Noland, J.L. (1983), "A proposed failure theory for brick masonry in compression", Proc. 3rd. Canadian Masonry Symp., Edmonton, 5.1-5.17.
  3. Banon, H., Biggs, J.M. and Irvine, H.M. (1981), "Seismic damage in reinforced concrete frames", J. Struct. Div., ASCE, 107(ST9), 1713-1729.
  4. Bertero, V.V. and Popov, E.P. (1977), "Seismic behaviour of ductile moment resisting reinforced concrete frames", Reinforced Concrete Structures in Seismic Zones, SP-53, American Concrete Institute, Detroit, 247-291.
  5. Chen, S-W. J., Hidalgo, P.A., Mayes, R.L., Clough, R.W., and McNiven, H.D. (1978), "Cyclic loading tests of masonry single piers, Volume 2 - Height to width ratio of 1", EERC Report No. 78/28, University of California, Berkeley.
  6. Darwin, D. and Nmai, C.K. (1986), "Energy dissipation in RC beams under cyclic load", J. Struct. Div., ASCE, 112(8), 1829-1846. https://doi.org/10.1061/(ASCE)0733-9445(1986)112:8(1829)
  7. Gosain, N.K., Brown, R.H. and Jirsa, J.O. (1977), "Shear requirements for load reversals on RC members", J. Struct. Div., ASCE, 103(ST7), 1461-1476.
  8. Hidalgo, P.A., Mayes, R.L., McNiven, H.D. and Clough, R.W. (1978), "Cyclic loading tests of masonry single piers, Vol. 1 - Height to width ratio of 0.2", EERC Report No. 78/27, University of California, Berkeley.
  9. Hwang, T.H. and Scribner, C.F. (1984), "R/C member cyclic response during various loadings", J. Struct. Div., ASCE, 110(3), 477-489. https://doi.org/10.1061/(ASCE)0733-9445(1984)110:3(477)
  10. Khoo, C.L. and Hendry, A.W. (1973), "A failure criterion for brickwork in axial compression", Proc. of the Third Int. Brick Masonry Conf., Essen, (ed. L. Foertig and K. Gobel), 139-45.
  11. Mayes, R.L. and Clough, R.W. (1975), "State-of-the-art in seismic strength of masonry - An evaluation and review", EERC Report No. 75 - 21, University of California, Berkeley.
  12. Mengi, Y. and McNiven, H.D. (1989), "A mathematical model for the in-plane non-linear earthquake behaviour of unreinforced masonry walls. Part 1: Experiments and proposed model", Earthq. Engrg. Struct. Dyn., 18, 233-247. https://doi.org/10.1002/eqe.4290180208
  13. Naraine, K. and Sinha, S. (1989), "Behaviour of brick masonry under cyclic compressive loading", J. Struct. Engng. 115(6), 1432-1445. https://doi.org/10.1061/(ASCE)0733-9445(1989)115:6(1432)
  14. Popov, E.P. (1968), Introduction to Mechanics of Solids, Prentice-Hall, Inc., Englewood Cliffs, N.J.
  15. Shing, P., Noland, J., Spaeh, H. and Klamerus, E. (1987), "Inelastic behaviour of masonry wall panels under inplane cyclic loads", Proc. 4th Nth. Am. Mas. Conf., Los Angeles, California, 42.1-42.14.
  16. Sinha, S.N. and Naraine, K. (1991), "Energy dissipation in brick masonry under cyclic biaxial compressive loading", Proc. of Inst. of Civil Engrs., Part 2, 173-181.
  17. Warren, D. and Lenczner, D. (1981), "Creep-time function for single leaf brickwork", Int. J. Masonry Constr., 2(1), 13-20.

Cited by

  1. Influence of bed joint orientation on interlocking grouted stabilised mud-flyash brick masonry under cyclic compressive loading vol.24, pp.5, 2006, https://doi.org/10.12989/sem.2006.24.5.585
  2. Behavior of Interlocking Grouted Stabilized Sand–Fly Ash Brick Masonry under Uniaxial Cyclic Compressive Loading vol.19, pp.11, 2007, https://doi.org/10.1061/(ASCE)0899-1561(2007)19:11(947)