Functional Motion Analysis of Wrist Joints

손목관절의 기능적 운동 특성의 동작 분석

  • Han Jung Soo (Center for Safety and Science Technology, Department of Industrial and Mechanical Systems Engineering, Hansung University)
  • 한정수 (한성대학교 기계시스템 공학, 산업 및 기계시스템 공학부)
  • Published : 2003.12.01

Abstract

Injuries of wrist in upper extremity is common onset in industrialized world. The development of joint arthroplasty and mechanical joint is area of research for biomechanical engineer and surgeon for a decade. Therefore. the knowledge of characteristic of joint motion is essential to develop the artificial wrist joint. In this study. the joint motions of wrist required for activities of daily living (ADLs). including personal hygiene and care. and general home activity were measured using flexible electrogoniometer. Total of 25 different daily activities were separated into four groups and tested on 15 subjects who did not show any abnormality of their joint functions. The maximum functional range of motion required for ADLs were obtained and standardized for analysis and comparison. Also. a least functional range of motion for ADLs were investigated. Results revealed that any significant differences were not found in least functional range of motion between left and right wrist to perform ADLs. However. a significant difference was found in different ADLs. Therefore. least range of motion obtained in this study can be used as basic data to design artificial joint and set a goal for surgeon to achieve appropriate treatment from patients.

Keywords

References

  1. Ayoub MA, Ayoub MM, Ramsey JD. A stereometric system for measuring human motion. Hum Factors 1970;12:523 35
  2. An KN, Chao EYS. Kinematic analysis of human movement. Ann Biomedical Engrg 1984;12:585-97 https://doi.org/10.1007/BF02371451
  3. Boone DC, Azen SP. Normal range of motion of joints in male subjects. J Bone Joint Surg 1979;61 A:756-9
  4. Brumfield R, Nickel V, Nickel E. Joint motion in wrist flexion and extension. South Med J 1966;59: 909-10 https://doi.org/10.1097/00007611-196608000-00008
  5. Cho EYS. Justification of triaxial goniometer for the measurement of joint rotation. J Biomech 1980;13:989-1006 https://doi.org/10.1016/0021-9290(80)90044-5
  6. Chao EYS, Morrey BF. Three-dimensional rotation of the elbow, J Biomech 1978;11:57-73
  7. Cooney WP, Beckenbaugh RD, Linscheid RL. Total wrist arthroplasty. Clin Orthop 1984;187:121-8
  8. Hayes WC, Feldman JM, Oatis C, Nixon JE. Gait analysis by multiaxial accelerometry. Dallas: Trans 24th Orth Res Soc, 1978;3:104
  9. Karpovich PV, Karpovich GP. Electrogoniometer: a new device for study of joints in action. Fed Proc 1959;18:79
  10. Kleinman WB, Steichen JB, Strickland JW. Management of chronic rotatory subluxation of the scaphoid by scapho-trapezio- trapezoid arthrodesis. J Hand Surg 1982;7:125-36 https://doi.org/10.1016/S0363-5023(82)80076-2
  11. Morris JRW. Accelerometry-a technique for the measurement of human body movement. J Biomech 1973;6;729-36
  12. Morrey BF, Askew LJ, An KN, Chao EYS. A biomechanical study of normal functional elbow motion. J Bone Joint Surg 1981;63A:872-7
  13. Palmer AK, Dobyns JH. Linscheid RL. Management of post traumatic instability of the wrist secondary to ligament rupture. J Hand Surg 1978;3:507-32 https://doi.org/10.1016/S0363-5023(78)80001-X
  14. Palmer AK, Werner FW, Murphy D, Glisson R. Functional wrist motion: a biomechanical study. J Hand Surg 1982;7:125-36 https://doi.org/10.1016/S0363-5023(82)80076-2
  15. Volz RG, Lieb M, Benjamin J. Biomechanics of the wrist. Clin Orthop 1980;149:112-17
  16. Watson HK, Hempton RF. Limited wrist arthrodesis. J Aand Surg 1980;5(4):320-7
  17. Youm Y, Flatt AE. Kinematics of the wrist. Clin Orthop 1980;149:21-32
  18. Youm Y, McMurtry RY, Flatt AE, Gillespie TE. Kinematics of the wrist. J Bone Joint Surg 1978; 60A(4):423-31 https://doi.org/10.2106/00004623-197860040-00001
  19. Youm YS. Analytical development in investigation of wrist kinematics. J Biomech 1979;12:613-21 https://doi.org/10.1016/0021-9290(79)90082-4
  20. Jaiyoung Ryu, William P. Functional Ranges of Motion of the Wrist Joint. Wrist Biomech 1992;144