Isolation and Identification of Bacteria from Air Conditioners and its Hygiene

에어컨내 세균의 분리, 동정 및 위생

  • Hong, Seong-Gap (Department of Microbiology, College of Medicine, The Catholic University of Korea) ;
  • Jeong, Yong-Tae (Department of Microbiology, College of Advanced Science, Dankook University) ;
  • Cheon, Gyeong-Ho (Century Corporation) ;
  • Baek, Sun-Yeong (Department of Microbiology, College of Medicine, The Catholic University of Korea)
  • 홍성갑 (가톨릭대학교 의과대학 미생물학교실) ;
  • 정용태 (단국대학교 첨단과학대학 미생물학과) ;
  • 천경호 (주식회사 센추리) ;
  • 백순영 (가톨릭대학교 의과대학 미생물학교실)
  • Published : 2003.01.01

Abstract

This study was performed to identify the microorganisms from air conditioners and to investigate hygiene management on air conditioners. Eight species of bacteria were isolated and identified from twenty samples of coolers in air conditioners; Pantoea sp., Bacillus circulans, Bacillus pumilus, Corynebacterium, Flavimonas oryzihabitans, Ochrobacterum anthropi, Micrococcus sp., and non fermented bacilli (NFB). One thousand and three hundreds twenty-two persons who used air conditioners in their houses were investigated about the state of hygiene management in their air conditioners. One thousand and one hundred thirty eight persons (86%) of the total investigated persons ventilated their air conditioners and 1,128 persons (85%) of them cleaned their air conditioners. However, 864 persons (66%) of them did not clean filters and 1,089 persons (82%) did not clean the heat exchangers, both of which air conditioners could be easily contaminated by microorganisms. From these results, we could conclude that the contaminants, bacteria as mentioned the above, in air conditioners could cause human disease such as respiratory infections if the number of bacteria increase in air conditioners. Thus, the removal of contaminants and the improved hygiene of the air conditioners can prevent human diseases caused by the released bacteria during the use of air conditioners.

본 연구에서는 에어컨 내에서 서식하는 세균을 분리하여 동정하였고 이들 에어컨에 대한 위생 관리에 대하여 조사하였다. 20개의 에어컨 냉각기에서 8종의 세균이 분리, 동정되었는데 그것들은 가장 많이 분리 동정된 Pantoea sp.를 비롯하여 Bacillus circulans, Bacillus pumilus, Corynebacterium, Flavimonas oryzihabitans, Ochrobacterum anthropi, Micrococcus sp., non fermented bacilli (NFB)이었다. 한편 에어컨 사용자 1,322명을 대상으로 에어컨의 위생관리 상태에 대하여 조사하였는데 설문자의 1,138명(86%)이 에어컨 사용시 환기를 하는 것으로 나타났다. 에어컨 청소에 있어서 1,128명(85%)이 청소를 하는 것으로 나타났지만 에어컨의 오염원들이 되는 에어컨의 필터 청소는 864명(66%)이 하지 않는 것으로 나타났고 에어컨의 열교환기는 1089명(82%)이 하지 않는 것으로 나타났다. 이런 결과로 상기에서 언급된 세균들과 같은 에어컨 오염원이 증가하면 호흡기 질환과 같은 인간의 질병을 초래할 수 있다는 것을 알 수 있었고 따라서 에어컨 사용시 에어컨의 오염원제거와 위생관리는 에어컨내 세균으로부터 발생되는 인간의 질병을 예방할 수 있을 것이다.

Keywords