Abstract
Experimental model studies were carried out to evaluate the end condition for drilled shafts by applying elastic impact on the top of the shaft, which is one of the various methods using stress waves. Typical impact responses corresponding to the various end conditions including free, fixed, rock-socketed, and soft-bottom with good and poor side contact conditions, were investigated. In order to simulate these renditions, mock-up shaft models made of cement mortar were used. Small-scale laboratory experiments were also performed, and field tests were carried out for the shafts that were socketed into weathered rock. It is found that the rock-socketed condition and depth of penetration into rock ran be identified from the reflection at the interface between the soil and rock in the waveform. The soft bottom rendition can be identified, only when the side contact between shaft and surrounding rock is poor, whereas it cannot be identified when the side contact is good because the waveform is similar to that of fixed end rendition.
본 논문은 탄성파를 이용한 비파괴검사 방법 중에 하나인 충격반향기법에 의하여 현장타설 말뚝기초의 선단 조건을 평가하는 연구로, 실내실험 및 현장실험을 수행하였다. 말뚝 선단 조건 평가를 위하여 직경 6cm, 길이 2m인 시멘트 모르타르 모형말뚝을 제작하였으며, 선단 조건은 자유단 조건, 고정단 조건, 암반근입 조건, 그리고 연약 선단 조건의 네 가지로 구분하였고 연약 선단 조건은 다시 말뚝과 주위 지반과의 접착 상태가 양호한 경우와 불량한 경우로 나누어 실내실험을 실시하였다. 실내실험 결과 탄성파 전파방법에 의하여 말뚝 선단 조건 가운데 자유단 조건, 고정단 조건 및 암반근입 조건을 각각 구별, 평가할 수 있었다. 또한 암반에 근입되어 있는 깊이도 정확히 산정할 수 있었으며, 말뚝과 주위 지반과의 접착상태가 불량한 경우의 연약 선단도 탐지할 수 있었다. 탄성파 전파방법의 현장 적용성을 평가하기 위하여 국내 현장에 건설되어 있는 현장타설 말뚝기초에 대하여 현장실험을 수행한 결과, 탄성파 전파방법에 의하여 현장타설 말뚝기초의 선단 조건 평가가 가능함을 확인하였다.