Large Cryosorption Pump for the NBI Test Stand

  • In, S.R. (Korea Atomic Energy research Institute) ;
  • Shim, H.J. (Korea Atomic Energy research Institute)
  • Published : 2003.12.01

Abstract

A large cryo-pumping system composed of 4 cryosorption pumps was designed and manufactured to satisfy the pressure requirements of the NBI test stand. The cryosorption pump consists of a thermal shield/baffle assembly and a cryopanel coated with activated carbon granules. The thermal shield is cooled by liquid nitrogen, and the cryopanel by a commercial helium refrigerator. The operation characteristics and vacuum performance of the cryosorption pump were investigated. The cooling down time of the cryopanel to 20 K was about 6 hours with a liquid nitrogen consumption rate of about 35 L/hr. The maximum pumping speed of the cryosorption pump for the hydrogen gas measured by the steady pressure method was about 90,000 L/s.