천공상태에 따른 오피스 창호의 적정 투과율 선정

Selection to the Optimal Windows Transmittance of Office Building on Sky Conditions

  • 임오연 (건양대학교 인테리어학과) ;
  • 김병수 (건양대학교 인테리어학과)
  • 발행 : 2003.06.01

초록

The purpose of this study is to select the optimal and minimum transmittance for visual amenity in office buildings. This study progressed as follows. The first, we select 5 films with various transmittance based on the current film makers whose films being used on the windows of office building nowadays and the case study of construction. And then we choose 6 kinds of transmittance as evaluation object including plain glass. The second, we made a mock-up models having different transmittance on the southern windows with model of real scale office building. The third, we select 17 pairs of adjectives for the evaluation of visual comfort on interior or exterior conditions with transmittance factor. The fourth, subjective evaluation experiment was done using selected evaluation adjectives and the result was analyzed. The results are as follows : the minimum transmittance appropriate for the office building is 30%∼40% and the optimal transmittance range is 40%∼60%.

키워드

참고문헌

  1. Acking C-A, Kuller R., 'The perception of an interior as a function of its colour' Ergonomics 15(6), 645-654, 1972
  2. Helena Bulow, Hube MSc., 'Subjective reactions to daylight in rooms: Effect of using low-emittance coatings on window', Lighting Res. Technol. 27(1)., 1995
  3. P Boyce BSc, N Eklund BS., 'Minimum Acceptable Transmittance of Glazing', Lighting Res. Technol. 27(3)., 1995
  4. 이진숙 . 진은미, 오피스 실내의 색채 평구구조분석을 위한 실험적 연구, 대한건축학회계획계논문집, 15권 8호(통권 130호)., 1999. 8
  5. 황성철 . 김강수, 실내 공간의 빛 환경 조절에 관한 연구, 대한건축학회계획계논문집, 18권 5호(통권 163호), 2002.5