DOI QR코드

DOI QR Code

Development of Biofilter System for Ammonia Removal in Livestock Facility

축산 시설의 암모니아 가스 제거용 바이오 필터 시스템 개발


Abstract

The purpose of this study was to develop a pilot scale bio-filter system removing ammonia gas with microorganisms. The system consisted of chaff(filter medium), a blower, a temperature sensor, a moisture sensor, a solenoid valve, and a heating system. Temperature and moisture contents were controlled via a PC to provide the microorganisms with proper environment. The microorganisms used in this study were Bacillius. coagulans NLRI T-6 and Pseudononas. putida NLRI S-21 of bacilli. Performance tests were performed to evaluate gas removal rate during 20 days. The result was shown that the removal rate was high in early days and gradually dropped below 90% without injecting the microbes. However, it was shown that when injecting the microbes, the removal rate was almost 100% and pH value was maintained at between 7 and 9 during the whole twenty-day period.

Keywords

References

  1. 시민 환경클럽. 1995. 21C를 위한 한국환경보고서. 신광문화사. 238-239.
  2. 윤세영, 이상규. 1992. 가축 분뇨 발효시 악취가스 생성억제재 사용 효과에 관한 연구. 한토비지:25(1):62-6.
  3. 이상규, 서장선. 1994. 농업용 미생물 개발 이용연구-가축분뇨 악취제거 미생물 개385-389.
  4. 川尻鐵也, 白石誠, 上林峯治, 白石太郞. 1995. 家畜ふん尿汚水, 惡臭の同時處理 システムの確立(1). 岡山總畜セ年報. 6:51-54.
  5. Auria, R. and C, Aycaguer. 1998. Influence of water content on degradation rates for ethanol in biofiltration. J. Air & Waste Manag. Associ., 48:65-70. https://doi.org/10.1080/10473289.1998.10463667
  6. O'neil, D. H. and V. R. Phillips. 1992a. A review of the control of odour nuisance from livestock buildings: Part 2, The costs of odour abatement system as predicted from ventilation requirements. J. Agric. Engng Res. 53:23-50. https://doi.org/10.1016/0021-8634(92)80072-Z
  7. O'neil, D. H. and V. R. Phillips. 1992b. A review of the control of odour nuisance from livestock buildings: Part 3, Properties of the odorous substances which have been identified in livestock wastes or in the air around them. J. agric. Engng. Res. 53:23-50. https://doi.org/10.1016/0021-8634(92)80072-Z
  8. Phillips, V. R., I. M. Scotford, R. P. White and R. L. Hartshorn. 1995. Minimum-cost biofilters for reducing odours and other aerial emission from livestock buildings : Part 1 basic airflow aspects. J. Agric. Engng. Res. 62:203-214. https://doi.org/10.1006/jaer.1995.1078