Thermal Analysis of Double-tube Triple-flow LNG Vaporization System

이중관 삼중흐름 열교환에 의한 LNG 기화시스템의 열적 해석

  • 윤상국 (한국해양대학교 공과대학 기계정보공학부)
  • Published : 2003.11.01

Abstract

As sea water is being used as only heat source of LNG open rack vaporizer, serious problem has been risen in LNG terminal by the lack of heating energy source for LNG vaporization due to the temperature drop of sea water in winter. In this paper the new double-tube triple-flow(TRIDEX) vaporizer was suggested to solve the problem and the system was thermally analysed. LPG(liquefied petroleum gas) and sea water were introduced as the heat sources for LNG TRIDEX vaporizer. The flow patterns of TRIDEX vaporizer are as follows: LNG flow in the annular space, PG(petroleum gas) flow in the inner tube, and sea water flow in the outside of the double pipe. The overall LNG vaporization system was consisted of TRIDEX vaporizer, LPG vaporizer and PG heater. LPG in TRIDEX was directly dispersed in the sea water desalination unit, so that LPG turns to be gas phase for the reuse in TRIDEX vaporizer. New TRIDEX vaporizer system for LNG evaporation was analysed as much more effective than the present single tube one in the case of colder temperature of sea water in winter.

Keywords

References

  1. 가스생산기술수첩 한국가스공사
  2. Principle of Desalination(2nd Ed.) Spiegler,K.S.;Laird,A.D.
  3. 고석문(외)