Sectional Differences in Tendon Response

  • Chun, Keyoung-Jin (Korea Institute of industrial Technology) ;
  • Robert P. Hubbard (Department of Mechanical Engineering, Michigan State University)
  • Published : 2003.08.01

Abstract

The objectives of this work here focus on the differences in responses to multiple cyclic tests of different sections along the length of the same tendon. Tendon specimens were obtained from the hindlimbs of canines and frozen to -70$^{\circ}C$. After thawing, specimens were mounted in the immersion bath at room temperature (22$^{\circ}C$) , preloaded to 0.13 N and then subjected to 3% or 4% of the initial length at a strain rate of 5%/sec. It was found that different sections of the same long tendons had different resistances to deformation. In general, the bone end sections were stiffer and carried greater loads for a given strain than the muscle end sections, and the mid-portions were the least stiff and carried the smallest loads for a given strain. The results of this study offer new information about the mechanical responses of collagenous tissues. We know more about their responses to multiple cyclic extensions and how their responses are different from the positions along the length of the tendon specimen. The nature and causes of these differences in the stiffness are not fully known. However, it is clear that differences in the mechanical response of tendons and other connective tissues are significant to musculoskeletal performance.

Keywords

References

  1. Benedict, J. V., Walker, L. B. and Harris, E. H., 1968. 'Stress-Strain Characteristics and Tensile Strength of Unembalmed Human Tendon,' J. of Biomechanics, Vol. 1, pp. 55-63 https://doi.org/10.1016/0021-9290(68)90038-9
  2. Berg, W. S., Stahurski, T. M., Morgan, J. M. and Greenwald, A. S., 1983, 'Mechanical Properties of Bovine Xenografts,' The 29th Annual Meeting, Orthopaedic Research Society
  3. Butler, D. L., Kay, M. D. and Stouffer, D. C., 1986, 'Comparison of Material Properties in Fascicle-Bone Units from Human Patellar Tendon and Knee Ligaments,' J. of Biomechanics, Vol. 19, No. 6, pp. 425-432 https://doi.org/10.1016/0021-9290(86)90019-9
  4. Chun, K. J. and Hubbard, R. P., 1986, 'Development of Reduced Relaxation Function and Stress Relaxtion with Paired Tendon,' ASME Bioengineering Division 1986 Symposium, ASME Winter Annual Meeting
  5. Chun, K. J. and Hubbard, R. P., 2001a, 'Constitutive Model of Tendon Responses to Multiple Cyclic Demands-Ⅰ: Experimental Analysis,' KSME International Journal, Vol. 15, No. 7, pp. 1002-1012
  6. Chun ,K. J. and Hubbard, R. P., 2001b, 'Constitutive Model of Tendon Responses to Multiple Cyclic Demands-Ⅱ: Theory and Comparison,' KSME International Journal, Vol. 15, No. 9, pp. 1281-1291
  7. Chun, K. J. and Hubbard, R. P., 2003, 'Tendon Responses Depending on Different Anatomical Locations,' KSME International Journal, Vol. 17, No. 7, pp. 1011-1015
  8. Elliot, D. H., 1965, 'Structure and Function of Mammalian Tendon,' Bio 1, Rev. 40 pp. 392-421
  9. Grood, E. S., Noyes, F. R., and Capsular, 1977, 'Structures of the Knee,' The 23rd Annual Meeting, 'Orthopaedic and Capsular Structures of the knee,' The 23rd Annual Meeting Orthopaedic Research Society
  10. Woo, S. L.-Y., Gomez, M. A., Amiel, D., Sanders, T. M., Gomez, M. A., Kuei, S. C., Garfin, S. R. and Akeson, W. H., 1980 'The Biomechanical and Biochemical Properties of Swine Tendons-Long Term Effects of Exercise on the Digital Extensors,' Connective Tissue Research, Vol. 7, pp. 177-183. https://doi.org/10.3109/03008208009152109
  11. Woo, S. L.-Y., Gomez, M. A., Amiel, D., Ritter, M. A., Gelberman, R. H. and Akeson,W.H., 1981, 'The Effect of Exercise on the Biomechanical and Biochemical Properties of Swine Digital Flexor Tendon,' J. Biomech. Engin., Vol. 103, pp. 51-56 https://doi.org/10.1115/1.3138246
  12. Woo. S. L.-Y., 1986, 'Biomechanics of Tendon and Ligaments,' Frontiers in Biomechanics. edited by Schmid-Schonbein, G. W., Woo, S. L.-Y. and Zweifach, B. W., Chapter, 14, pp. 180-195