Tensile Characteristics and Behavior of Blood Vessels from Human Brain in Uniaxial Tensile Test

  • Suh, Chang-Min (Department of Mechanical Engineering, Kyungpook National University) ;
  • Kim, Sung-Ho (Graduate School of Mechanical Engineering, Kyungpook National University) ;
  • Ken L. Monson (Department of Mechanical Engineering, University of California) ;
  • Werner Goldsmith (Department of Mechanical Engineering, University of California)
  • 발행 : 2003.07.01

초록

The rupture of blood vessels in the human brain results in serious pathological and medical problems. In particular, brain hemorrhage and hematomas resulting from impact to the head are a major cause of death. As such, investigating the tensile behavior and rupture of blood vessels in the brain is very important from a medical point of view. In the present study, the tensile characteristics of the blood vessels in the human brain were analyzed using a quasi-static uniaxial tensile test, and the properties of the arteries and veins compared. In addition, to compare the tensile behavior and demonstrate the validity of the experimental results, blood vessels from the legs of pigs were also tested and analyzed. The overall results were in accordance with the histological structures and previous medical reports.

키워드

참고문헌

  1. Arbogast, E., 1997, 'A High-Frequency Shear Device for Testing Soft Biological Tissues,' Journals of biomechanics, Vol. 30, No. 7, pp. 757-759 https://doi.org/10.1016/S0021-9290(97)00023-7
  2. Carew, E.O., Barber, J.E. and Vesely, I., 2000, 'Role of Preconditioning Time in Repeated Testing of Aortic Valve Tissue: Validation Through Quasilinear Viscoelastic Theory,' Annals of Biomedical Engineering, Vol. 28, pp. 1093-1100 https://doi.org/10.1114/1.1310221
  3. Eshel, H. and Lanir, Y., 2001, 'Effect of Strain Level and Proteoglycan Depletion on Preconditioning and Viscoelastic Response of Rat Dorsal Skin,' Annals of Bioengneering, Vol. 29, pp. 164-172
  4. Fung, Y.C., 1981, 'Biomechanics : Mechanical Properties of Living Tissues,' Pringer-Verag, New York
  5. Kim, Y.E., Nam, D.H. and Koh, C.H., 1997, 'Development of Head-Neck Complex Dummy for Experimental Study,' Journal of KSME, Vol. 21, No. 7, pp. 1058-1072
  6. Lee, M.C. and Haut, R.C., 1989, 'Insensitivity of Tensile Failure Properties of Human Bridging Veins to Strain Rate : Implications in Biomechanics of Subdural Hematoma,' Journal of Biomechanics, 22, pp. 537-542 https://doi.org/10.1016/0021-9290(89)90005-5
  7. Lowenhielm, P., 1978, 'Dynamic Strain Tolerance of Blood Vessels at Different Post-mortem Conditions,' Journal of Bioengineering, Vol. 2, pp. 509-515
  8. Luchter, S. and Walz, M.C., 1996, 'Long-Term Consequences of Head Injury,' 'Traumatic Brain Injury - Bioscience and Biomechanics,' Mary Ann Liebert. Inc. Edited by F.A. Bandak, R. H. Eppinger, A. K. Ommaya, pp. 9-18
  9. Martini, F., 1989, 'Fundamentals of Anatomy and Physiology,' Prentice Hall, Englewood Cliffs,New Jersey, USA
  10. Scahtzmann, L., Brunner, P. and Staubli, H.U., 1998, 'Effect of Cycle Preconditioning on the Tensile Properties of Human Quadriceps Tendons and Patellar Ligaments,' Knee Surgery, Sports Traumatology, Arthroscopy, Vol. 6 [Suppl. 1], pp. 56-61 https://doi.org/10.1007/s001670050224
  11. Thibault, K., 1997, 'Pediatric Head Injuries : the Influence of Brain and Skull Mechanical Properties,' Ph. D. Dissertation, University of Pennsylvania