참고문헌
- Butterworth, D. and Hewitt. G. F., 1977, Two phase Flow and Heat Transfer, 1st ed. Oxford University Press
- Collier, J. G. and Thome, J. R., 1994, Convective Boiling and Condensation, 3rd ed. McGraw-Hill
- Didion, D. A. and Bivens, D. B., 1990, 'Role of Refrigerant Mixtures as Altenatives to CFCs,' Int. J. Refrig., Vol. 13, pp. 163-175 https://doi.org/10.1016/0140-7007(90)90071-4
- Domanski, P. A. and Didion, D. A., 1993, 'Thermodynamic Evaluation of R-22 Alternative Refrigerants and Refrigerant Mixtures,' ASHRAE Trans., Vol. 99, Part 2
- Gill, L. E., Hewiitt, G. F. and Lacey, P. M. C., 1964, 'Sampling Probe Studies of the Gas Core in Annular Two Phase Flow: Ⅱ,Studies of the Effect of Phase Flow Rates on Phase and Velocity Distribution,' Chem. Eng. Sci., Vol. 19, pp. 665-682 https://doi.org/10.1016/0009-2509(64)85054-5
- Hashizume, K., Ogiwara, H. and Taniguchi, H., 1985, 'Flow Pattern, Void Fraction and Pressure Drop of Refrigerant Two-phase Flow in a Horizontal Pipe-Ⅰ:Analysis of Frictional Pressure Drop,' Int. J. Multiphase Flow, Vol. 11, pp. 643-658 https://doi.org/10.1016/0301-9322(85)90084-9
- Hihara, E., Tanida, K. and Saito, T., 1989, 'Forced Convective Boiling Experiments of Binary Mixtures,' Int. J. JSME, Vol. 32, pp. 98-106
- Hong, E. C., Kim, M. S. and Ro. S. T., 1995, 'Prediction of Evaporative Heat Transfer Coefficient of Pure Refrigerants and Binary Refrigerant Mixtures in a Horizontal Tube,' Proc. of the 19th International Congress of Refrigeration, Ausust 20-25, The Hague, The Netherlands, Vol. IVa, pp. 313-320
- Jung, D. S., McLinden, M., Radermacher, R. and Didion, D. A., 1989, 'Horizontal Flow Boiling Heat Transfer Experiments with Mixture of R22/R114,' Int. J. Heat Mass Transfer, Vol. 32, pp. 131-145 https://doi.org/10.1016/0017-9310(89)90097-5
- Kays, W. M. and Crawford, M. E., 1993, Convective Heat and Mass Transfer, 3rd ed. McGraw Hill, Ch. 11
- Kedzierski, M. A., Kim, J. H. and Didion, D. A., 1992, 'Causes of the Apparent Heat Transfer Degradation for Refrigerant Mixtures,' ASME HTD Two-Phase Flow and Heat Transfer, Vol. 197, pp. 149-158
- Kruse, H., 1981, 'The Advantages of Non-azeotropic Refigerant Mixtures for Heat Pump Application,' Int. J. Refrig., Vol. 4, pp. 119-125 https://doi.org/10.1016/0140-7007(81)90102-X
- Murata, K. and Hashizume, K., 1993, 'Forced Convective Boiling of Nonazeotropic Refrigerant Mixtures Inside Tube,' J. Heat Transfer, Vol. 115, pp. 680-689 https://doi.org/10.1115/1.2910739
- Price, B. C. and Bell, K. J., 1974, 'Design of Binary Vapor Condensers Using the Colburn-Drew Equations,' AIChE Symp. Series, Vol. 70, No. 138, pp. 163-171
- Reid, R. C., Prausnitz, C. A. and Poling, B. E., 1987, The Properties of Gases and Liquids, 4th ed. McGraw Hill
- Ross, H., Radermacher, R., Di Marzo, M. and Didion, D. A., 1987, 'Horizontal Flow Boiling of Pure and Mixed Refrigerants,' Int. J. Heat Mass Transfer, Vol. 30, pp. 979-992 https://doi.org/10.1016/0017-9310(87)90016-0
- Shin, J. Y., Kim, M. S. and Ro, S. T., 1997, 'Experimental Study on Forced Convective Boiling Heat Transfer of Pure Refrigerants and Refrigerant Mixtures in a Horizontal Tube,' Int. J. Refrig., Vol. 20, No. 4, pp. 267-275 https://doi.org/10.1016/S0140-7007(97)00004-2