The RTD Measurement on a Submerged Bio-Reactor using a Radioisotope Tracer and the RTD Analysis

  • Published : 2003.06.01

Abstract

This paper presents a residence time distribution (RTD) measurement method using a radioisotope tracer and the estimation method of RTD model parameters to analyze a submerged bio-reactor. The mathematical RTD models have been investigated to represent the flow behavior and the existence of stagnant regions in the reactor. Knowing the parameters of the RTD model is important for understanding the mixing characteristics of a reactor The radioisotope tracer experiment was carried out by injecting a radioisotope tracer as a pulse into the inlet of the reactor and recording the change of its concentration at the outlet of the reactor to obtain the experimental RTD response. The parameter estimation was performed by the Levenberg-Marquardt optimization algorithm. The proposed scheme allowed the parameter estimation of RTD model suggested by Adler-Hovorka with very low deviations. The estimation procedure is shown to lead to accurate estimation of the RTD parameters and to a good agreement between experimental and simulated response.

Keywords

References

  1. Process Analysis and Simulation D. M. Himmelblau;K. B. Bischoff
  2. Technical Report Series, no. 316 Guide Book on Radioisotope Tracers in Industry
  3. Chemical Engineering Science v.55 Interpretation of Residence Time Distribution Data A. D. Martin https://doi.org/10.1016/S0009-2509(00)00108-1
  4. Vydavatelstvi CVUT Analysis and Diagnostics of Industrial Processes by Radiotracers and Radioisotope Sealed Sources Jiri Thyn;Rudolf Zitny
  5. Introduction to Optimum Design J. S. Arora
  6. J. Soc. Indust. Appl. Math. v.11 no.2 An Algorithm for Least Squares Estimation of Nonlinear Parameters D. W. Marquardt https://doi.org/10.1137/0111030
  7. Measurement and Detection of Radiation N. Tsoulfanidis