References
- Y. Bar-Cohen, 'Electroactive polymers as artificial muscles - capabilities, potentials and challenges' , Handbook on Biomimetics, Section 11, Chap. 8, pp. 1- 13, 2000
- R. Kanno, S. Tadokoro, T. Takamori and K. Oguro, '3-dimensional dynamic model of ionic conducting polymer gel film(ICPF) actuator', Proceedings of IEEE International Conference on Systems, Man and Cybernetics, pp. 2179-2184, 1996 https://doi.org/10.1109/ICSMC.1996.565486
- S. Guo, T. Fukuda, T. Nakamura, F. Arai, K. Oguro and M. Negoro, 'Micro active guide wire catheter system -characteristic evaluation, electrical model and operability evaluation of micro active catheter -', Proceedings of the 1996 IEEE International Conference on Robotics and Automation, pp. 2226-2231, April 1996 https://doi.org/10.1109/ROBOT.1996.506495
- S. Tadoko et al., 'Development of a distributed actuation device consisting of soft gel actuator elements' , Proceedings of the 1998 IEEE International Conference on Robotics and Automation, pp. 2155-2160, May 1998 https://doi.org/10.1109/ROBOT.1998.680640
- M. Shainpoor and K wang J Kim, 'Novel ionic polymeric hydraulic actuators', Proceedings of SPIE, Vol. 4329, pp. 164-173, 2001 https://doi.org/10.1117/12.432642
- A. Keshavarzi, M. Shahinpoor, Kwang J. Kim and J. Lantz, 'Blood pessure, pulse rate, and rhythm measurement using ionic polymer-metal composites sensors', Proceedings of SPIE, Vol. 3669, pp. 369-376, 1999 https://doi.org/10.1117/12.349695
- Y. Bar-Cohen et al., 'A CAE approach in application of Nafion-Pt composite(ICPF) actuators -analysis for surface wipers of NASA MUSES-CN nanorovers' , Proceedings of SPIE, Vol. 3987, pp. 262-272, 2000 https://doi.org/10.1117/12.387785
- Y. Bar-Cohen, T. Xue, M. Shainpoor, J. Simpson. and J. Smith, 'Flexible, low-mass robotic arm actuated by electroactive polymers and operated equivalently to human arm and hand', Robotics 98: The 3rd Conference and Exposition/Demonstration on Robotics for Challenging Environments Sponsored by American Society of Civil Engineers, April 1998 https://doi.org/10.1061/40337(205)3
- S. Guo, S. Hata, K Sugumoto, T. Fukuda, K. Oguro 'Development of a new type of capsule micropump', Proceedings of the 1999 IEEE International Conference on Robotics & Automation, Detroit, Michigan, pp. 2171-2176, May 1999 https://doi.org/10.1109/ROBOT.1999.770428
- S. Nemat-Nasser and J. Y. Li, 'Electromechanical response of ionic polymer-metal composites', Journal of Applied Physics, vol. 87, pp. 3321-3331, 2000 https://doi.org/10.1063/1.372343
- M. Shahinpoor and Kwang J. Kim, 'Design, development and testing of a multi -fingered heart compression! assist device equipped with IPMC artificial muscles', Proceedings of SPIE, Vol. 4329, pp. 411-420, 2001 https://doi.org/10.1117/12.432673
- 이승기, 김병목, 김병규, 박정호, '캐스팅 방법에 의해 제작한 이온성 고분자-금속 복합체 액추에이터의 기계적 특성 분석', 대한전기학회논문지, 제52권, 3호, pp. 144-151, 2003. 3
- 차승은, 박정호, 이승기, '백금의 무전해 도금에 의한 이온성 고분자-금속 복합물 액추에이터의 제작 공정 및 특성 측정', 대한전기학회논문지, 제51권, 9호, pp.455-463, 2002. 9