Abstract
In this study, the effect of temperature and soil confining stress on geosyntheic stress-strain properties was quantified by performing the temperature dependent confined tension tests for four types of geosynthetic including woven geotextile, composite, geomembrane and geogrid specimen. Temperature instrumentation on the GRS-retaining wall constructed in Jaechon-shi area was also performed to examine the a seasonal temperature variation of geosynthetic reinforcements in the backfill. Based on the test results, a comparison was made between unconfined and confined moduli far each temperature to quantify the soil confinement and temperature effect on stress-strain properties. And it was also proposed that the simple expressions for the secant moduli of geosynthetics as a function of temperature and confining stress on geosynthetics. As a result of the FDM analysis of GRS-retaining wall, the method of considering the effect of temperature and confining stress on geosynthetic reinforcements when performing the FDM analysis of GRS-retaining wall was proposed.
본 연구에서는, 4가지 종류의 토목섬유를 대상으로 토목섬유에 가해지는 구속응력의 크기 및 토목섬유 온도 변화에 따른 응력-변형률 관계를 규명하기 위한 온도제어 구속인장시험(Temperature Dependent Confined Tension Test)을 수행하였다. 또한, 보강토옹벽 내부 보강재의 온도변화를 측정하기 위한 온도계측을 수행하였다. 온도제어 구속인장시험 결과를 토대로하여, 토목섬유에 가해지는 구속응력 및 온도 변화에 따른 토목섬유 할선계수의 변화량을 정량적으로 평가할 수 있는 관계식을 제시하였다. 본 관계식을 이용한 토목섬유 보강토옹벽의 유한차분해석 예를 통해 다양한 보강토구조물의 변위해석시 온도변화에 따른 보강재의 특성변화를 고려할 수 있는 기법을 제시하였다. 유한차분해석 결과, 보강재의 온도가 5$^\circ$인 경우에 비하여 30$^\circ$인 경우에 전면부벽체의 최대변위량은 약 46.4% 증가하는 것으로 나타났다.