Experiments and MAAP4 Assessment for Core Mixture Level Depletion After Safety Injection Failure During Long-Term Cooling of a Cold Leg LB-LOCA

  • Kim, Y. S. (Seoul University) ;
  • B. U. Bae (Seoul University) ;
  • Park, G. C. (Seoul University) ;
  • K. Y. Sub (Seoul University) ;
  • Lee, U. C . (Seoul University)
  • Published : 2003.04.01

Abstract

Since DBA(Design Basis Accidents) has been studied rather separately from SA(Severe Accidents) in the conventional nuclear reactor safety analysis, the thermal hydraulics during transition between DBA and SA has not been identified so much as each accident itself. Thus, in this study, the thermal hydraulic behavior from DBA to the commencement of SA has been experimentally and analytically investigated for the long-term cooling phase of LB-LOCA(Large-Break Loss-of-Coolant Accident). Experiments were conducted for both cases of the loop seal open and closed in an integral test loop, named as SNUF (Seoul National University Facility), which was scaled down to l/6.4 in length and 1/178 in area of the APR1400 (Advanced Power Reactor 1400MWe). The core mixture level was a main measured value since it took major role in the fuel heat-up rate, the location of fuel melting initiation and the channel blockage by melting material during SA. Experimental results were compared to MAAP4.03 to assess its model of calculating the core mixture level. MAAP4.03 overestimates the core two- phase mixture level because sweep-out and spill-over and the measures to simulate the status of loop seal are not included, which is against the conservatism. Thus, it is recommended that MAAP4.03 should be improved to simulate the thermal hydraulic phenomena, such as sweep-out, spill-over and the status of loop seal.

Keywords

References

  1. 'RELAP Code Manual', U. S. Nuclear Regulatory Commission, Washington, USA, (1999)
  2. P. Hofmann, 'Current knowledge on core degradation phenomena, a review', Journal of nuclear materials, (1999) https://doi.org/10.1016/S0022-3115(98)00899-X
  3. 'Standard Safety Analysis Report for the Korean Next Generation Reactor', Korea Electric Power Corporation, Seoul, Korea, (1999)
  4. Hong, S.J. and Park, G.C., 'Study on Post-Blowdown of Hot-Leg Large Break Loss-of-Coolant-Accident in the View of Mass and Energy Release Analysis', Nuclear Engineering and Design', Nuclear Engineering and Design, (2001) https://doi.org/10.1016/S0029-5493(01)00452-6
  5. Ishii, M. and Kataoka, I., 'Scaling Laws for Thermal Hydraulic System under Single Phase and Two Phase Natural Circulation', Nuclear Engineering and Design, (1984) https://doi.org/10.1016/0029-5493(84)90287-5
  6. Yun B. J. et al., 'Development of Scaling Law for the Direct ECC Bypass during LB-LOCA Reflood Phase with Direct Vessel Injection System', Proceedings of the Korean Nuclear Society, (2000)
  7. 'MAAP4.03 User's Guide', Electric Power Research Institute, Palo Alto, CA, USA, (1994)
  8. 'MARS2.1 Code Manual', Korea Atomic Energy Research Institute, Korea Atomic Energy Research Institute, Taejon, Korea, (2002)
  9. Tong, L. S., 'Boiling Heat Transfer and Two Phase Flow', Wiley and Sons, Inc., New York, NY, USA, (1965)
  10. 'Flow of Fluids Through Valves, Fittings and Pipe', CRANE, New York, USA, (1985)
  11. 'Decay Heat Power in light water reactors', ANSI/ANS 5.1-1979, ANS, USA, (1979)