Abstract
Current steel-framed building design codes are based on theoretical and experimental researches on the conventional structural steel. However, the yield phenomenon of austenitic stainless steel, which is characterized by continuous yielding, is quite different from that of conventional structural steel. The offset strength, which should determine the design strength, may affect the limits of width-thickness ratio of current design codes. Stub column test results showed that the limits of width-thickness ratio satisfied both ASD and LRFD codes when 0.2% offset strength was regarded as design strength. In addition, the local buckling strengths of all stainless steel stub columns did not decrease rapidly compared with those of conventional structural steel columns, even though the width-thickness ratio exceeded the design limit.
현행 강구조 설계기준은 일반 구조용 강재의 이론과 실험에 의한 결과에 근거를 한다. 그러나 오스테나이트계 스테인리스 강재는 일반 구조용 강재와 달리 연속항복 현상이 일어난다. 설계기준강도를 결정짓는 옾셋강도는 현행 설계기준의 판폭두께비 제한값에 영향을 미친다. 단주압축 실험결과 0.2% 옾셋강도를 설계기준강도로 하면 허용응력도 설계법과 한계상태 설계법에서 정하고 있는 판폭두께비의 규정을 모두 만족하였다. 또한 일반 구조용 강재와 달리 판폭두께비를 만족시키지 못하는 경우에도 최대내력에 도달하기 전에 국부좌굴이 발생하지만 급격한 내력저하는 일어나지 않았다.