Abstract

Titanium acetylacetonate was used in the construction of a PVC-based membrane electrode. This sensor shows very good selectivity for iodide ion over a wide variety of common inorganic and organic anions. It exhibits Nernstian behavior with a slope of 59.1 mV per decade. The working concentration ranges of the sensor are with a detection limit of $3.0\;{\times}\;10^{-6}\;M$. The response time of the sensor is very fast (<8 s), and can be used for at least twelve weeks in the pH range of 4.0-9.2. The best performance was obtained with a membrane composition of 30% PVC, 65% dibutylphthalate, 3% titanium acetylacetonate and 2% hexadecyltrimethylammonium bromide. The proposed sensor was successfully applied as an indicator electrode for titration of iodide with silver ion.

Keywords

References

  1. Buhlmann, P.; Pretsch, E.; Backer, E. Chem. Rev. 1998, 98, 1593. https://doi.org/10.1021/cr970113+
  2. Bakker, E.; Buhlmann, P.; Pretsch, E. Chem. Rev. 1997, 97, 3083. https://doi.org/10.1021/cr940394a
  3. Amini, M. K.; Shahrokhian, S.; Tangestaninejad, S. Anal. Chim.Acta 1999, 402, 137. https://doi.org/10.1016/S0003-2670(99)00549-8
  4. Li, Z. Q.; Wu, Z. Y.; Yuan, R.; Ying, M.; Shen, G. L.; Yu, R. Q.Electrochim. Acta 1999, 44, 2543. https://doi.org/10.1016/S0013-4686(98)00361-2
  5. Amemiya, S.; Buhlmann, P.; Umezawa, Y.; Jagessar, R. C.; Burns,D. H. Anal. Chem. 1999, 71, 1049. https://doi.org/10.1021/ac980952b
  6. Channiotaksi, N. A.; Chasser, A. M.; Meyerhoff, M. E. Anal.Chem. 1998, 60, 185. https://doi.org/10.1021/ac00153a020
  7. Meyerhoff, M. E.; Pranitis, D. M.; Yim, H. S.; Chaniotakis, N. A.;Park, S. B. Am. Chem. Soc. Symposium Series 1989, 403, 26.
  8. Yuan, R.; Chai, Y.; Liu, D.; Gao, D.; Li, J.; Yu, R. Anal. Chem.1993, 65, 2572. https://doi.org/10.1021/ac00067a005
  9. Poursaberi, T.; Hosseini, M.; Taghizadeh, M.; Pirelahi, H.;Shamsipur, M.; Ganjali, M. R. Microchem. J. 2002, 72, 77. https://doi.org/10.1016/S0026-265X(01)00159-X
  10. Ganjali, M. R.; Poursaberi, T.; Hosseini, M.; Salavati-Niasari, M.;Yousefi, M.; Shamsipur, M. Anal. Sci. 2002, 18, 289. https://doi.org/10.2116/analsci.18.289
  11. Poursaberi, T.; Salavati-Niasari, M.; Khodabakhsh, S.; Hajiagha-Babaei, L.; Shamsipur, M.; Yousefi, M.; Rouhani, S.; Ganjali, M.R. Anal. Lett. 2001, 34, 2621. https://doi.org/10.1081/AL-100108409
  12. Ganjali, M. R.; Poursaberi, T.; Basiripour, F.; Salavati-Niasari, M.;Yousefi, M.; Shamsipur, M.; Feresnius, J. Anal. Chem. 2001, 370,1091. https://doi.org/10.1007/s002160100915
  13. Shamsipur, M.; Yousefi, M.; Hosseini, M.; Ganjali, M. R.;Sharghi, H.; Naemi, H. Anal. Chem. 2001, 73, 2869. https://doi.org/10.1021/ac001449d
  14. Shamsipur, M.; Yousefi, M.; Ganjali, M. R.; Poursaberi, T.; Faal-Rastgar, M. Sens. Actuatore. B 2002, 82, 105. https://doi.org/10.1016/S0925-4005(01)00997-2
  15. Ganjali, M. R.; Naji, L.; Poursaberi, T.; Taghizadeh, M.; Pirelahi,H.; Yousefi, M.; Yeganeh-Faal, A.; Shamsipur, M. Talanta 2002,in press.
  16. Ganjali, M. R.; Mizani, F.; Emami, M.; Salavati-Niasari, M.;Shamsipur, M.; Yousefi, M.; Javanbakht, M. Electroanalysis 2002,in press.
  17. Kamata, S.; Bhale, A.; Fukunaga, Y.; Murata, A. Anal. Chem.1998, 60, 2464. https://doi.org/10.1021/ac00173a006
  18. IUPAC Analytical Chemistry Division, Commission on AnalyticalNomenclature Pure. Appl. Chem. 1976, 48, 127. https://doi.org/10.1351/pac197648010127
  19. Umezawa, Y.; Umezawa, K.; Sato, H. Pure. Appl. Chem. 1995, 67,507. https://doi.org/10.1351/pac199567030507
  20. Ying, M.; Yuan, R.; Zhang, X. M.; Song, Y.; Li, Z.; Shen, G.; Yu,R. Analyst 1997, 122, 1143. https://doi.org/10.1039/a700544j
  21. El Amarani, F.; Garica-Raurich, J.; Sastre, A.; Beyer, L.; Florido,A. Anal. Chim. Acta 1999, 402, 129. https://doi.org/10.1016/S0003-2670(99)00562-0
  22. El Amarani, F.; Garica-Raurich, J.; Sastre, A.; Beyer, L.; Florido,A. Anal. Chim. Acta 1996, 329, 247. https://doi.org/10.1016/0003-2670(96)00115-8
  23. Li, Z.; Yuan, R.; Ying, M.; Song, Y.; Shen, G.; Yu, R. Anal. Lett.1997, 30, 1455. https://doi.org/10.1080/00032719708001667

Cited by

  1. Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade vol.8, pp.4, 2008, https://doi.org/10.3390/s8042331
  2. Application of Tetra Cyclohexyl Tin(IV) as an Anionic Carrier for the Construction of a New Salicylate Membrane Sensor vol.54, pp.4, 2013, https://doi.org/10.1002/jccs.200700139
  3. Ionophore in a PVC-Membrane Sensor vol.161, pp.6, 2014, https://doi.org/10.1149/2.051406jes
  4. Iodide-Selective Electrodes Based on Bis[N(2-methyl-phenyl) 4-Nitro-thiobenzamidato]mercury(II) and Bis[N-phenyl 3,5-Dinitro-thiobenzamidato]mercury(II) Carriers vol.17, pp.19, 2005, https://doi.org/10.1002/elan.200503278
  5. Synthesis and Crystal Structure of Tris(1,3-diphenyl-1,3-propanedionato)Titanium(III) vol.25, pp.6, 2003, https://doi.org/10.5012/bkcs.2004.25.6.921
  6. La(III) Selective Membrane Sensor Based on a New N-N Schiff's Base vol.26, pp.1, 2003, https://doi.org/10.5012/bkcs.2005.26.1.038
  7. Novel Triiodide PVC-Based Membrane Sensor Based on a Charge Transfer Complex of Iodine and Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone vol.26, pp.11, 2005, https://doi.org/10.5012/bkcs.2005.26.11.1738
  8. Zn2+ PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one vol.26, pp.4, 2005, https://doi.org/10.5012/bkcs.2005.26.4.579
  9. Novel Colorimetric Sensing of Anion with Gold Nanoparticles-Embedded Plasticized Polymer Membrane vol.27, pp.12, 2003, https://doi.org/10.5012/bkcs.2006.27.12.2081
  10. Novel Tm(III) Membrane Sensor Based on 2,2'-Dianiline Disulfide and Its Application for the Fluoride Monitoring of Mouth Wash Preparations vol.27, pp.9, 2006, https://doi.org/10.5012/bkcs.2006.27.9.1418
  11. Determination of Copper in Black, Red Pepper and the Waste Water Samples by a Highly Selective Sensitive Cu(II) Microelectrode Based on a New Hexadentates Schiff's Base vol.27, pp.9, 2003, https://doi.org/10.5012/bkcs.2006.27.9.1439
  12. Perchlorate-selective membrane sensors based on two nickel-hexaazamacrocycle complexes vol.120, pp.2, 2003, https://doi.org/10.1016/j.snb.2006.03.002
  13. Iodide recognition by the N,N-bis-succinamide-based dendritic molecule [CH2C(O)NHC(CH2CH2C(O)OtBu)3]2 vol.137, pp.1, 2003, https://doi.org/10.1016/j.snb.2008.12.013