Force per unit Displacement according to the Shape of a Clasp Arm and Flexibility of the Material
Clasp arm의 형상과 재료 탄성에 따른 단위 변위에 대한 힘
- Lim, Dong-Chun (Dept. of Dental Lab. Technology, Gwangju Health College)
- 임동천 (광주보건대학 치기공과)
- Published : 2002.01.30
Abstract
The purpose of this study is to evaluate force per unit displacements according to the shape of a clasp arm and flexibility of the material. Effect of four shape parameters of a clasp, base width and thickness and tip width and thickness, on tip displacement and force per unit displacement was investigated to get the fact that displacement and force per unit displacement at the tip increase as thickness and width of clasp arm increase just as expected. But force per unit displacement is much more affected by the change in thickness than by change in width. So it is effective to increase the thickness rather than width in order to increase the force at the tip using the same amount of the material.