MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM

CAD/CAM으로 제작한 코누스내관의 변연적합

  • Kim In-Sup (Department of Prosthodontics, College of Dentistry, Chosun University) ;
  • Kang Dong-Wan (Department of Prosthodontics, College of Dentistry, Chosun University)
  • 김인섭 (조선대학교 치과대학 보철학교실) ;
  • 강동완 (조선대학교 치과대학 보철학교실)
  • Published : 2002.02.01

Abstract

This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{\mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{\pm}43{\mu}m$, 28.9% of the specimen showed marginal gap over $100{\mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).

Keywords

References

  1. LaBarre, E.E., Belser, U.C., Meyer. J.M., Watanabe, L., 'Computer-aided design and transverse strength of screw-retained attachment.' Int. J. Prosthodont., 7: 323-328, 1994
  2. Liu, P.R., Isenberg, B.P., Leinfelder, K.F., 'Evaluating CAD-CAM generated ceramic veneers.' J.A.D.A., 124:59-63, 1993
  3. Andersson, M., Carlsson, L., Persson, M., Bergman, B., 'Accuracy of machine milling and spark erosion with a CAD/CAM system. J. Prosthet. Dent., 76:187-193, 1996
  4. Schmitt, S.M., Chance, D.A., Cronin, R. J., 'Refining cast implant-retained restorations by electrical discharge machining.' J. Prosthet. Dent., 73: 280-283, 1995
  5. Evans, D.B., 'Correcting the fit of implantretained restorations by electric discharge machining.' J. Prosthet. Dent., 77:212-215, 1997
  6. Maeda, Y., Minoura, M., Tsutsumi, S., Okada, M., Nokubi, T.. 'A CAD/CAM System for Removable Denture. Part I: Fabrication of Complete Dentures.' Int. J. Prosthodont., 7:17-21, 1994
  7. Rinke, S., Huls, A., .Jahn, L., 'Marginal Accuracy and Fracture Strength of Conventional and Copy-Milled All-Ceramic Crowns.' Int. J. Prosthodont., 8:303-310, 1995
  8. Mormann, W.H., and Schug J., 'Grinding precision and accuracy of fit of CEREC2 CAD-CIM inlays.' J.A.D.A., 128:47-53, 1997
  9. Andersson. M., Razzoog M.E., Od n. A., Hegenbarth E.A., and Lang. BR., 'Procera : A new way to achieve an all-ceramic crown.' Quintessence Int., 29:285-296, 1998
  10. Persson, M., Andersson, M., and Bergman, B., 'The accuracy of a high-precision digitizer for CAD/CAM of crowns.', 74:223-229, 1995
  11. Besimo, C., Jeger, C., and Guggenheim, R., 'Marginal adaptation of titanium frameworks produced by CAD/CAM techniques.' Int J Prosthodont., 10:541-546, 1997
  12. Dastane, A., Vaidyanathan, T.K., Vaidyanathan, J., Mehra, R., and Hesby, R., 'Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surface., J. Oral Rehabil., 23:25-34, 1996
  13. Kawata, N., Ono, H., Nishi, Y., Hamano, T., and Nagaoka, E., 'Trial of duplication procedure for complete denture by CAD/CAM.' J. Oral Rehabil., 24:540-248
  14. Sohmura, T., and Takahashi, J., 'Use of CAD/CAM system to fabricate dental prostheses. part 1: CAD for a clinical crown restoration.' Int. J. Prosthodont., 8:252-258, 1995
  15. Sturdevant, J.R., Bayne, S.C., and Heymann. H.O., Margin gap size of ceramic inlays using second-generation CAD/CAM equipment.' J. Esthet. Dent., 11:206-214, 1999
  16. Kim, IS, Kim, BO, Yoo, KH, Kang, DW. 'Design and fabrication of inner konus crown using three dimensional computer graphics, The journal of Korean academy of Prosthodonics, 38(4): 544-551, 2000
  17. 하종국 편저 ‘CNC공4작법’ 서울 : 일진사 1997 p.74-751
  18. Van Roekel, N.B.., 'Electrical Discharge machining in Dentistry., 'Int. J. Prosthodont., 5:114-121, 1992
  19. Chan, D.C.N., Blackman, R, Kaiser, D.A., and Chung, K., 'The effect of sprue design on the marginal accuracy of titanium castings.' J. Oral Rehabil., 25:424-429, 1998
  20. Jenkins, C.B.G., and Phillips, R.W., 'An evaluation of five inlay investing techniques employed with different types of wax patterns.' J. Prosthet. Dent., 25:211-220, 1971
  21. Mitchem, J.C., Wagner, P.C., and Ferracane, J.L., 'Marginal adaptation of the Concept inlay system.' Am. J. Dent., 7:232-234, 1994
  22. McLean, J.W., and vonfraunhofer, J.A., 'The estimation of cement film thickness by an in vivo technique.' Br. Dent. J., Aug 3:131:107-111, 1971
  23. Mclean, J.W., polycarboxylate cements. Five years' experience in general practice.' Br. Dent. J., and 132:9-15, 1972
  24. Denissen, H.W., Van der Zel, J.M., and Van Waas, M.A.J., 'Measurement of the margins of partial-coverage tooth preparation for CAD/CAM.' Int. J. Prosthodont., 12:395-400, 1999
  25. May, K.B., Russell, M.M., Razzoog, M.E., Lang. B.R. 'Precision of fit: The procera allceram crown.' J. Prosthet. Dent., 80: 394-404, 1998
  26. 기계공학대사전편찬위 ‘기계공학대사전’ 서울 : 집문사 1995 p.826
  27. Small, B.W., 'Product review: All-ceramic system.' General Dent., 446-448, 1998
  28. Sulaiman, F., Chai, J., Jameson, L.M., and Wozniak, W.T., ‘A comparison of marginal fit of In-ceram. IPS Empress. and Procera Crowns.' Int. J. Prosthodont., 10:478-484, 1997
  29. Willer, J., Rossbach. A., and Weber, H.P., 'Computer-assisted milling of dental restoration using a new CAD/CAM data acquisition system.' J. Prosthet. Dent., 80:326-353, 1998
  30. Kydd, W.L., Nicholls, J.I. Harrington, G., and Freeman, M., 'Marginal leakage of cast gold crowns luted with zinc phosphate cement: an in vivo study.' J, Prosthet. Dent., 75:9-13, 1996
  31. Christensen, G.J., 'Marginal fit of gold inlay casting.' J. Prosthet. Dent., 16:297-305, 1966
  32. Belser, U.C., Mecentee, M.l., and Richter, W.A., 'Fit of three porcelain- fused-to-metal marginal designs in vivo: A scanning electron microscope study.' J. Prosthet. Dent., 53:24-29, 1985
  33. Byrne, G., Goodacre, C.J. Dykema, RW., Moore B.K., 'Comparative casting accuracy of high-palladium alloys.' J. Prosthet. Dent., 55:297-301, 1986 https://doi.org/10.1016/0022-3913(86)90106-X
  34. West, A.J., Goodacre, C.J., Moore, B.K., and Dykema, R.W., 'A comparison of four techniques for fabricating collarless metal ceramic crowns.' J. Prosthet. Dent., 54:636-642, 1985
  35. Valderrama. S., Van Roekel, N., Andersson, M., Goodacre, C.J., and Munoz, CA., 'A comparison of the marginal and internal adaptation of titanium and gold-platinurn-palladium metal ceramic crowns.' Int. J. Prosthodont., 8:29-37, 1995
  36. Molin, M.K., Karlsson, S.L., and Kristiansen, MS., 'Influence of film thickness on joint bend strength of ceramic/resin composite joint.' Dental Material, 12:245-249, 1996