임플랜트 유지 나사 머리 홈의 설계가 나사를 푸는 시간에 미치는 영향에 관한 연구

PRELIMINARY STUDY ON THE DESIGN OF IMPLANT ABUTMENT SCREW HEAD FOR RAPID FASTENING & LOOSENING

  • 이재봉 (서울대학교 치과대학 보철학교실)
  • Lee, Jai-Bong (Dept. of Prosthodontics, School of Dentistry, Seoul National University)
  • 발행 : 2002.04.01

초록

For the purpose of decreasing the chair time in implant cases, the time needed to loosening and fastening the screw must be shortened. Nowadays, the two typical designs of screw head are slot and hexa form. This study aimed at the shortening of loosening and fastening time by modifying the slot and hexa form. Total of twelve dentists participate in these experiments, four of them were experienced and eight of them were novice dentists. 1. There were many differences in the speeds of screw loosening and fastening between personal experiences. Experienced dentists are faster than novice dentists. 2. There were many differences in the speeds by angulation of the implant, by the conditions of the muscle tonicity. 3. Revised slot and hexa Heads show the slightly shortened time for acrew looseing and fastening.

키워드

참고문헌

  1. Albrektsson T, Dahl E, Enbom L, Engevall S, Engquist B, Eriksson AR, Feldmann G, Freiberg N, Glantz PO, Kjellman O, Osseointegratedoral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants. J Periodontol. 1988 May:59(5) :287-96
  2. Zarb GA Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent. 1990 Aug:64(2): 185-94
  3. Jemt T, Linden B, Lekholm U. Failures and complicationsin 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants. 1992 Spring:7(1):4G-4
  4. Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent. 1999 May: 81(5) :537-52. Review
  5. Ekfeldt A. Carlsson GE. Borjesson G. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. Int J Oral Maxillofac Implants. 1994 Mar-Apr: 9(2) :179-83
  6. Haas R. Mensdorff-Pouilly N, Mailath G, Watzek G. R Branemark single tooth implants: a preliminary report of 76 implants. J Prosthet Dent. 1995 Mar:73(3) :274-9
  7. Becker W, Becker BE. Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study, J Prosthet Dent. 1995 Jul: 74(1): 51-5
  8. Gunne J. Astrand P. Ahlen K. Borg K. Olsson M. Implants in partially edentulous patieents. Clin Oral Implant Res 1992:3:49-56
  9. Jemt T, Pettersson P. A 3-year follow-up study on single implant treatment. J Dent. 1993 Aug:21(4) :203-8
  10. emt T, Book K. Linden B, Urde G. Failures and complications in 92 consecutively inserted overdentures supported by Branemark implants in severely resorbed edentulous maxillae: a study from prosthetic treatment to first annual check-up. Int J Oral Maxillofac Implants. 1992 Summer.7(2): 162-7
  11. Albrektsson T. A multicenter report on osseointegrated oral implants. J Prosthet Dent. 1988 Jul: 60 (1) :75-84. Review
  12. Tolman DE, Laney WR. Tissue-integrated dental prostheses: the first 78 months of experience at the Mayo Clinic. Mayo Clin Proc. 1993 Apr:68(4) :323-31
  13. Allen PF, McMillan AS. Smith DG. R. Complications and maintenance requirements of implant-supported prostheses provided in a UKdental hospital. Br Dent J. 1997 Apr 26:182(8):298-302
  14. Gunne J, Jemt T. Linden B. Implant treatment in partially edentulous patients: a report on prostheses after 3 years. Int J Prosthodont. 1994 Mar-Apr:7(2): 143-8
  15. Avivi-Arber L. Zarb GA. Clinical effectiveness of implant-supported single-tooth replacement: the Toronto Study. Int J Oral Maxillofac Implants. 1996 May-Jun: 11(3) :311-21
  16. Zarb GA Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: Problems and complications encountered. J Prosthet Dent. 1990 Aug:64(2): 185-94
  17. Naert I, Quirynen M, van Steenberghe D, Darius P. A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects.J Prosthet Dent. 1992 Dec:68(6) :949-56
  18. Wismeyer D, van Waas MA Vermeeren JI. Overdentures supported by ITI implants: a 6.5-year evaluation of patient satisfaction and prosthetic aftercare. Int J Oral Maxillofac Implants. 1995 Nov-Dec: 10(6):744-
  19. Laboda G. RLife-threatening hemorrhage after placement of an endosseous implant: report of case. J Am Dent Assoc. 1990 Nov: 121 (5) :599-600
  20. ten Bruggenkate CM, Krekeler G, Kraaijenhagen HA, Foitzik C, Oosterbeek HS. Hemorrhage of the floor of the mouth resulting from lingual perforation during implant placement: a clinical report. Int J Oral Maxillofac Implants. 1993:8(3) :329-34
  21. Adell R. Lekholm U, RockIer B, Branemark PI, Lindhe J, Eriksson B, Sbordone L. Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study. Int J Oral Maxillofac Surg. 1986 Feb:15(1):39-52
  22. Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants. 1994 Mar-Apr: 9(2) :191-6
  23. Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH Jr, Polizzi G, Zarb GA Herrmann I. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants. 1991 Spring: 6 (1) :29-36
  24. Cordioli G, Castagna S, Consolati E. Singletooth implant rehabilitation: a retrospective study of 67 implants. Int J Prosthodont. 1994 Nov-Dec: 7(6) :525-31
  25. Andersson B, Odman P, Lindvall AM, Branemark PI. Five-year prospective study of prosthodontic and surgical single-tooth implant treatment in general practices and at a specialist clinic. Int J Prosthodont. 1998 JulAug: 11(4) :351-5
  26. Patterson EA Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants. 1992 Spring: 7(1) :26-33
  27. Gross M, Abramovich I. Weiss EI. Microleakage at the abutment-implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants. 1999 JanFeb:14(1) :94-100
  28. Kramer,R. Procedure for obturating the access canal and preventing the loosening of the abutment screw in an implant-retained fixed prosthesis. J Prosthet Dent 1999:81:234-6
  29. Adrian ED, Krantz WA, Ivanhoe JR, Edge MJ. An improved index for the waxed stage of an implant-retained framework. J Prosthet Dent. 1991 Nov:66(5) :665-9 https://doi.org/10.1016/0022-3913(91)90450-B
  30. Artzi Z, Dreiangel A. A screw lock for singletooth implant superstructures. J Am Dent Assoc. 1999 May: 130(5) :677-82
  31. 신승요, 신근하, 김영조. 나사기술총람, 문운당. 1995
  32. 이호용, 임종연, 이종찬, 황병복. 제조공학, 반도출판사. 1998
  33. 김동우, 김태형, 허정원, 황규완. 기계공학개론, 원창출판사, 1999