Abstract

Seven hip roof building models for $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$, $30^{\circ}$, $35^{\circ}$ and $40^{\circ}$ roof pitch with large overhangs of 1.1 m were tested in a wind tunnel at the university of Roorkee, India to investigate wind pressure distributions over hip roofs for various roof pitch and wind direction. The results show that the roof pitch and wind direction do significantly affect the magnitude and distribution of the roof pressures. The $40^{\circ}$ roof pitch has been found to experience the highest peak suctions at the roof corners amongst the seven hip roofs tested. Pressures on $15^{\circ}$, $20^{\circ}$ and $30^{\circ}$ hip roofs are comparable with those reported by Xu and Reardon (1998). Meecham et al. (1991) for $18.4^{\circ}$ hip roof is compatible with $15^{\circ}$ hip roof of the present study. Holmes's works (1994) on gable roof have also been compared with the present work. Zoning for codification has also been attempted since IS875 (Part-3) does not include this information. A comparison for design value has also been made with BRE Report No. 346.

Keywords

References

  1. AS1170.2 (1989), "SAA loading code, Part-2: wind loads, Standard Association of Australia", NSW, Australia.
  2. BRE Digest (1989), "The assessment of wind loads part 6: loading coefficients for typical buildings", Building Research Establishment, Department of Environment, Garsten, WD2 7JR.
  3. Cochran, L.S. (1992), "Wind tunnel modelling of low-rise structures", Ph.D. Thesis, Colorado State University, USA.
  4. Davenport, A.G. (1964), "Note on the distribution of the largest value of a random function with application to gust loading".
  5. Davenport, A.G., Surry, D. and Stathopoulos, T. (1972), "Wind loads on low-rise buildings, final report of phase I and II", Boundary Layer Wind Tunnel Report BLWT-SS4, University of Western Ontario, Canada.
  6. Federal Emergency Management Agency (1992), "Building performance in hurricane Andrew in Florida observations", Recommendations and Technical Guidance, Federal Insurance Administration, USA.
  7. Holmes, J.D. (1994), "Wind pressures on tropical housing", J. Wind Eng. Ind. Aerod., 53, 105-123. https://doi.org/10.1016/0167-6105(94)90021-3
  8. IS875 (part-3) 1987, "Indian code of practice for design loads (other than earthquake) for buildings and structures", Bureau of Indian Standards, New Delhi, India.
  9. Isyumove, N., Fediw, A.A., Colaco, J. and Banavalkar, P.V. (1992), "Performance of a tall building under wind action", J. Wind Eng. Ind. Aerod., 41-44, 1053-1064.
  10. Lin, J.X., Surry, D. and Tieleman, H.W. (1995), "The distribution of pressure near roof corners of flat roof low building", J. Wind Eng. Ind. Aerod., 56, 235-265. https://doi.org/10.1016/0167-6105(94)00089-V
  11. Meecham, D., Surry, D. and Davenport, A.G. (1991), "The magnitude and distribution of wind induced pressures on hip and gable roofs", J. Wind Eng. Ind. Aerod., 38, 257-272. https://doi.org/10.1016/0167-6105(91)90046-Y
  12. Okada, H. and Young, C.H. (1992), "Comparison of wind tunnel and full scale pressure measurement tests on Texas Tech. building", J. Wind Eng. & Ind. Aerod., 41-44, 1601-1612.
  13. Rofail, A.W. (1995), "Full-scale/model scale comparison of wind pressures on TTU building", 9th International Conference on Wind Engineering, New Delhi, 1055-1066.
  14. Sparks, P.R., Baker, J., Belville, J. and Perry, D.C. (1985), "Hurricane Eleva, gulf coast, Aug 29-Sept 2, committee on natural disasters", Commission on Engineering and Technical Systems, Natural Research Council, USA.
  15. Sparks, P.R., Hessig, M.L., Murden, J.A. and Sill, B.L. (1988), "On the failure of single storey wood frame houses in severe storms", J. Wind Eng. Ind. Aerod., 29, 245-252. https://doi.org/10.1016/0167-6105(88)90162-6
  16. Tieleman, H.W., Hajj, M.R. and Reinhold, T.A. (1997), "Wind tunnel simulation requirements to assess wind loads on low-rise buildings", Proc. 2EACWE, Geneva, Italy, 1093-1100.
  17. Tieleman, H.W. (1996), "Model/full scale comparison of pressures on the roof of the TTU experimental building", J. Wind Eng. Ind. Aerod., 65, 133-142. https://doi.org/10.1016/S0167-6105(97)00030-5
  18. Tieleman, H.W., Surry, D. and Mehta, K.C. (1996), "Full/model scale comparison of surface pressures on Texas Tech. experimental building", J. Wind Eng. Ind. Aerod., 61, 1-23. https://doi.org/10.1016/0167-6105(96)00042-6
  19. Xu, Y.L. and Reardon, G.F. (1998), "Variation of wind pressures on hip roof with roof pitch", J. Wind Eng. Ind. Aerod., 73, 267-284. https://doi.org/10.1016/S0167-6105(97)00291-2

Cited by

  1. Wind loads on contemporary Australian housing vol.17, pp.2, 2016, https://doi.org/10.1080/13287982.2016.1229375
  2. Experimental study of wind loads on gable roofs of low-rise buildings with overhangs 2018, https://doi.org/10.1007/s11709-018-0449-7
  3. Post Windstorm Evaluation of Critical Aspects Causing Damage to Rural Houses in the Northern Region of Peninsular Malaysia vol.103, 2017, https://doi.org/10.1051/matecconf/201710303016
  4. Stationary vortices attached to flat roofs vol.98, pp.1, 2010, https://doi.org/10.1016/j.jweia.2009.09.001
  5. The Effects of the Presence of a Kitchen House on the Wind Flow Surrounding a Low-Rise Building vol.13, pp.23, 2002, https://doi.org/10.3390/en13236243