DOI QR코드

DOI QR Code

Seismic repair of reinforced concrete beam-column subassemblages of modern structures by epoxy injection technique

  • Tsonos, Alexander G. (Aristotle University of Thessaloniki, School of Engineering, Department of Civil Engineering, Division of Structural Engineering)
  • Received : 2001.11.13
  • Accepted : 2002.08.14
  • Published : 2002.11.25

Abstract

The use of the epoxy pressure injection technique to rehabilitate reinforced concrete beam-column joints damaged by strong earthquakes is investigated experimentally and analytically. Two one-half-scale exterior beam-column joint specimens were exposed to reverse cyclic loading similar to that generated from strong earthquake ground motion, resulting in damage. Both specimens were typical of new structures and incorporated full seismic details in current building codes. Thus the first specimen was designed according to Eurocode 2 and Eurocode 8 and the second specimen was designed according to ACI-318 (1995) and ACI-ASCE Committee 352 (1985). The specimens were then repaired with an epoxy pressure injection technique. The repaired specimens were subjected to the same displacement history as that imposed on the original specimens. The results indicate that the epoxy pressure injection technique was effective in restoring the strength, stiffness and energy dissipation capacity of specimens representing a modem design.

Keywords

References

  1. Abdel-Fattah, A.B. and Wight, J.K. (1987), "Study of moving beam plastic hinging zones for earthquake - resistant design of R/C buildings", ACI Struct. J., 84(1), 31-39.
  2. ACI-ASCE Committee 352 (1985), "Recommendations for design of beam-column joints in monolithic reinforced concrete structures (ACI 352R-85)", American Concrete Institute, Farmington Hills, Mich., 19pp.
  3. ACI Committee 318 (1995), "Building code requirements for structural concrete (ACI 318-95) and commentary (318R-95)", American Concrete Institute, Farmington Hills, Mich., 369pp.
  4. Agbabian, M.S., Higazy, E.M., Abdel-Ghaffar, A.M. and Elnashai, A.S. (1994), "Experimental observations on the seismic shear performance of RC beam-to-column connections subjected to varying axial column force", J. Earthq. Eng. Struct. Dyn., 23, 859-876. https://doi.org/10.1002/eqe.4290230804
  5. Bertero, V.V. and Popov, E.P. (1977), "Seismic behaviour of ductile moment - resisting reinforced concrete frames", American Concrete Institute, SP53-11, 247-291.
  6. Bertero, V.V. (1979), "Seismic behavior of structural concrete linear elements (beams, columns) and their connections", Bulletin d' Information, CEB 131, Paris, 125-199.
  7. CEB (1985), "Model code of seismic design of concrete structures", Bulletin d' Information, CEB 165, Paris.
  8. Cheung, P.C., Paulay, T. and Park, R. (1991), "New Zealand tests on full-scale reinforced concrete beam-columnslab subassemblages designed for earthquake resistance", American Concrete Institute, SP 123-1, 1-38.
  9. Dritsos. S. (2001), "Repair and strengthening of reinforced concrete structures", Patras, 309pp. (in Greek).
  10. Durrani, A.J. and Wight, J.K. (1987), "Earthquake resistance of reinforced concrete interior connections including a floor slab", ACI Struct. J., 84(5), 400-406.
  11. Ehsani, M.R. and Wight, J.K. (1985), "Effect of transverse beams and slab on behavior of reinforced concrete beam-to-column connections", ACI Struct. J., 82(2), 188-195.
  12. Eurocode No 2 (1993), "Concrete design of structures", Commission of the European Communities.
  13. Eurocode No 8 (1994), "Earthquake resistant design of structures", Commission of European Communities.
  14. French, C.W., Thorp, G.A. and Tsai, W. (1990), "Epoxy repair techniques for moderate earthquake damage", ACI Struct. J., 87(4), 416-424.
  15. Hanson, N.W. and Conner, H.W. (1967), "Seismic resistance of reinforced concrete beam-column joints", Proceedings, ASCE, 93(ST5), 533-560.
  16. Higazy, E.M., Elnashai, A.S. and Agbabian, M. (1996), "Behavior of beam-column connections under axial column tension", J. Struct. Eng., 122(5), 501-511. https://doi.org/10.1061/(ASCE)0733-9445(1996)122:5(501)
  17. Higazy, E.M. and Elnashai, A.S. (1997), "Energy - based technique for seismic performance assessment of interior beam-column joints", J. Earthq. Eng., 1(4), 675-692. https://doi.org/10.1142/S136324699700026X
  18. Jirsa, J.O., Editor (1991), "Design of beam-column joints for seismic resistance", American Concrete Institute, SP 123, 518pp.
  19. Joh, O., Goto, Y. and Shibata, T. (1991), "Influence of transverse joint and beam reinforcement and relocation of plastic hinge region on beam-column joint stiffness deterioration", American Concrete Institute, SP 123-8, 187-223.
  20. Karayannis, C., Chalioris, C. and Sideris, K. (1998), "Effectiveness of RC beam-column connection repair using epoxy resin injections", J. Earthq. Eng., 2(2), 217-240. https://doi.org/10.1142/S1363246998000101
  21. Kitayama, K., Otani, S. and Aoyama, H. (1991), "Development of design criteria for RC interior beam-column joints", American Concrete Institute, SP 123-4, 97-123.
  22. Kupfer, H., Hilsdorf, H.K. and Rusch, H. (1969), "Behavior of concrete under biaxial stresses", ACI J., Proceedings, 66(8), 656-667.
  23. Lee, D.L.N., Wight, J.K. and Hanson, R.D. (1980), "Repair of damaged reinforced concrete frame structures", Seventh World Conference on Earthquake Engineering, Istanbul, Turkey, 7, 2486-2491.
  24. Meinheit, D.F. and Jirsa, J.O. (1981), "Shear strength of R/C beam-column connections", Proceedings ASCE, 107(ST11), 2227-2244.
  25. NEHRP (1985), "Recommended provisions for the development of seismic regulations for new buildings - Part 3, Appendix: Existing Buildings", FEMA 97, Buildings Seismic Safety Council, Washington, D.C., 142pp.
  26. NZS 3101:1982, "Code of practice for the design of concrete structures", Standards Association of New Zealand, Wellington, Part 1, 127pp., Part 2, 156pp.
  27. Park, R. and Paulay, T. (1975), Reinforced Concrete Structures, John Wiley Publications, New York, 769pp.
  28. Paulay, T. and Park, R. (1984), "Joints in reinforced concrete frames designed for earthquake resistance", Research Report 84-9, Department of Civil Engineering, University of Canterbury, Christchurch, New Zealand, 72pp.
  29. Penelis, G.G. and Kappos, J.A. (1997), "Earthquake - resistant concrete structures", E & FN SPON, An Imprint of Chapman & Hall, 572pp.
  30. Popov, E.P. and Bertero, V.V. (1975), "Repaired R/C members under cyclic loading", Earthq. Eng. Struct. Dyn., (Chichester), 4, 129-144. https://doi.org/10.1002/eqe.4290040204
  31. Rodriguez, M. and Park, R. (1991), "Repair and strengthening of reinforced concrete buildings for seismic resistance", J. Earthquake Spectra, 7(3), 439-459. https://doi.org/10.1193/1.1585636
  32. Scott, B.D., Park, R. and Priestley, M.J.N. (1982), "Stress-strain behavior of concrete confined by overlapping hoops at low and high strain rates", ACI J., Proceedings, 79(1), 13-27.
  33. Tasai, A. (1992), "Effective repair with resin for bond failure of RC members", 10th World Conference on Earthquake Engineering, Madrid, Spain, 5211-5216.
  34. Tegos, I.A. (1984), "Contribution to the study and improvement of earthquake-resistant mechanical properties of low slenderness structural elements", PhD thesis, Aristotle University of Thessaloniki, Appendix 13, 8, 185 pp. (in Greek).
  35. Tsonos, A. (1996), "Towards a new approach in the design of R/C beam-column joints", Technika Chronika, Scientific Journal of the Technical Chamber of Greece, 16(1-2), 69-82 (in Greek).
  36. Tsonos, A.G. (1997), "Shear strength of ductile reinforced concrete beam-to-column connections, for seismic resistant structures", J. European Earthquake Engineering, 2, 54-64.
  37. Tsonos, A.G. (1999), "Lateral load response of strengthened reinforced concrete beam-to-column joints", ACI Struct. J., 96(1), 46-56.
  38. UNDP/UNIDO PROJECT RER/79/015, UNIDO (1983), "Repair and strengthening of reinforced concrete, stone and brick masonry buildings", Building Construction Under Seismic Conditions in the Balkan Regions, 5, Vienna, 231pp.

Cited by

  1. Effectiveness of CFRP jackets in post-earthquake and pre-earthquake retrofitting of beam-column subassemblages vol.27, pp.4, 2007, https://doi.org/10.12989/sem.2007.27.4.393
  2. Investigation of shear strength models for exterior RC beam-column joint vol.58, pp.3, 2016, https://doi.org/10.12989/sem.2016.58.3.475
  3. Improvement of the earthquake resistance of R/C beam-column joints under the influence of P-△ effect and axial force variations using inclined bars vol.18, pp.4, 2004, https://doi.org/10.12989/sem.2004.18.4.389
  4. Pre-earthquake and post-earthquake retrofitting of poorly detailed exterior RC beam-to-column joints vol.109, 2016, https://doi.org/10.1016/j.engstruct.2015.11.009
  5. Parametrical study of the behavior of exterior unreinforced concrete beam-column joints through numerical modeling vol.18, pp.2, 2016, https://doi.org/10.12989/cac.2016.18.2.215
  6. Seismic retrofit schemes for RC structures and local-global consequences vol.8, pp.1, 2006, https://doi.org/10.1002/pse.208
  7. Effectiveness of CFRP-jackets and RC-jackets in post-earthquake and pre-earthquake retrofitting of beam–column subassemblages vol.30, pp.3, 2008, https://doi.org/10.1016/j.engstruct.2007.05.008
  8. Influence of high column axial loads in exterior R/C beam-column joints vol.18, pp.2, 2014, https://doi.org/10.1007/s12205-014-1201-z
  9. Shear strength criteria for design of RC beam–column joints in building codes pp.1573-1456, 2018, https://doi.org/10.1007/s10518-018-0492-8
  10. Post-earthquake repair and strengthening of reinforced concrete beam-column connections vol.36, pp.2, 2002, https://doi.org/10.5459/bnzsee.36.2.73-93
  11. QUANTIFYING THE EFFECTS OF EPOXY REPAIR OF REINFORCED CONCRETE PLASTIC HINGES vol.53, pp.1, 2002, https://doi.org/10.5459/bnzsee.53.1.37-51
  12. Structural health monitoring of seismically vulnerable RC frames under lateral cyclic loading vol.19, pp.1, 2002, https://doi.org/10.12989/eas.2020.19.1.29
  13. Interior beam column joints with nominal joint shear reinforcement versus unsymmetrical chamfers vol.220, pp.None, 2002, https://doi.org/10.1016/j.engstruct.2020.110907
  14. Behaviour of RC beam-column joint with varying location of construction joints in the column vol.20, pp.1, 2021, https://doi.org/10.12989/eas.2021.20.1.029
  15. Strengthening of deficient RC joints with diagonally placed external C-FRP ropes vol.20, pp.1, 2002, https://doi.org/10.12989/eas.2021.20.1.123
  16. SSI effects on the redistribution of seismic forces in one-storey R/C buildings vol.20, pp.3, 2021, https://doi.org/10.12989/eas.2021.20.3.261
  17. Effectiveness of the Novel Rehabilitation Method of Seismically Damaged RC Joints Using C-FRP Ropes and Comparison with Widely Applied Method Using C-FRP Sheets-Experimental Investigation vol.13, pp.11, 2021, https://doi.org/10.3390/su13116454
  18. Behaviour of repaired RC beam-column joints using welded wire mesh and jacketed with polymer modified mortar vol.21, pp.1, 2002, https://doi.org/10.12989/eas.2021.21.1.079
  19. Full-scale experimental testing of RC beam-column joints strengthened using CFRP ropes as external reinforcement vol.250, pp.None, 2002, https://doi.org/10.1016/j.engstruct.2021.113305