Performance Analysis of the Lubricating Oil Feed Pump by the Anslysis of the Flow Network

유로망 해석에 의한 윤활유 공급펌프 성능 해석

  • Published : 2002.11.30

Abstract

In this paper, the cause of the discrepancy of the inlet and outlet flow of the lubricating oil feed pump was analyzed by the flow measurement and the analysis of the flow network. At first, we thought that the flow difference was induced by a leak in the middle of the flow network. But, through the flow measurement using ultrasonic flow meter and the performance analysis of the pump, we knew that the cause of the flow difference was due to a drop in efficiency of the pump according to the pressure drop of the outlet. Also, we knew that the shape of the piping had no effect on the efficiency of the pump.

Keywords