Abstract

For elimination DC component, the optical recording systems generally exploit WRDS (word-end running digital sum) criterion. However, its performance is degraded if the lengths of the control bits and codewords are increased. Another criterion is MSW (mean-square weight) method. Whereas MSW criterion has the complexity, this hs optimal performance. In this paper, we have proposed a new dc-component suppression method (MPRDS, minimum peak RDS) of the modulation codes for high density optical recording system. This method requires less complexity than MSW's, and the performance is near to MSW's even if the lengths of the control bits and codewords are increased.

제어 비트를 통한 직류 성분 제거 방법으로 주로 코드워드 끝단에서의 WRDS(word-end running digital sum) 기준을 적용하고 있다. WRDS 기준에 의한 직류 성분 제거 방법은 계산 및 구현이 쉬운 반면에 제어 비트 및 코드워드의 길이가 길어질수록 성능이 저하되는 단점이 있다. 복잡도가 높은 대신 최적의 성능을 갖는 방법으로 MSW(mean-square weight) 기준이 있다. 본 논문에서는 MPRDS(minimum peak RDS)라는 고밀도 광 기록 저장 장치를 위한 변조 코드의 새로운 직류 성분 제거 방법을 제안하였다. 이 방법은 계산 및 구현상의 복잡도가 MSW 기준에 비해 현저하게 낮으면서도 제어 비트 및 코드워드의 길이가 증가하더라도 MSW 기준에 의한 성능에 근접함을 입증하였다.

Keywords

References

  1. Richard B. Wells, 'Applied Coding and Information Theory for Engineers,' Prentice Hall, 1999
  2. Kees A. Schouhamer Immink, 'Codes for Mass Data Storage Systems,' Shannon Foundation Pub., 1999
  3. G.L. Pierobon, 'Codes for zero spectral density at zero frequency,' IEEE Trans.Inform. Theory, vol. IT-30, no. 2, PP. 435-439, March 1984
  4. Paul H. Siegel and Jack K. Wolf, 'Modulation and coding for information storage,' IEEE Communications Magazine, pp. 68-85, Dec. 1991