DOI QR코드

DOI QR Code

A Study on Detection of Broken Rotor Bars in Induction Motors Using Current Signature Analysis

전류신호를 이용한 유도전동기의 회전자봉 결함검출에 관한 연구

  • 신대철 (호서대학교 전기공학과) ;
  • 정병훈 (호서대학교 전기공학과)
  • Published : 2002.04.01

Abstract

The unexpected failure of the induction motor makes the downtime of production, and the cost of the process cessation enormous. To reduce the downtime and increase the reliability of the motor, the vibration measurements for the fault detection have been used previously. Recently motor current signature analysis(MCSA) has been adapted for the fault detection and diagnosis of the motors. MCSA provides a powerful analysis tool for detecting the presence of mechanical and electrical faults in both the motor and driven equipment. In this paper, the fault severity of the rotor bar has been derived in terms of the resistance change which is calculated from the equivalent circuit model. Results show that the fault of the rotor can be easily detected and the measured value of the resistance change is verified by the detected fault from on-site tests using MCSA for the induction motors in an iron foundry.

Keywords

References

  1. Bowers, S. V., 1996. "Integrated Strategy far Predictive Maintenance of AC Induction Motors," P/PM Technology Magazine, pp. 34-40.
  2. Taver, P. J., Gaydon, B. G., and Ward, D. M., 1986, "Monitoring Generators & Large Motors." IEE Proceedings, Vol. 133, Pt. B. No. 3
  3. Bate, G. H., 1990, "Vibration Diagnostics for Industhal Electric Motor Drives," Bruel & Kjaer Application Note BO 0269-12. pp. 3-12
  4. Lang, G. F., 1994, "Of Cages, Induction, Deduction, Bars, Vars and Squirrels," Journal of Sound and Vibration.
  5. Maxwell, J. H., 1981, "Diagnosing Induction Motor Vibration," Hydrocarbon Processing Magazine, pp. 117-120.
  6. Penman, J., Dey, M. N., Tait, A. J. and Bryan, W. E., 1986, "Condition Monitoring of Electrical Drives," IEE Proc. Vol. 133, Pt. B, No. 3, pp. 142-148. https://doi.org/10.1049/ip-d.1986.0020
  7. Haynes, H. D., and Kryter, R. C., 1989, "Condition Monitoring of Machinery Using of Motor Current Signature," Journal of Sound and Vibration, pp. 14-21
  8. Berry, P. E., and James, E., 1999, "Comparison of Motor Current Analysis and Vibration Analysis in Detecting Rotor Bar and Air-gap Eccentricity Problems in Induction Motors," Technical Associates of Charlotte, Charlotte, NC.
  9. Smith, S.. 1995, "Summary of the Modulation Theory from a Report Written for the Navy," Oak Ridge National Laboratory.
  10. Sen, P. C., 1997, Principles of Electhc Machines and Power Electronics, John Wiley &Sons, Inc.
  11. Burstein, N., and Bellarmy, J., 1996, "Reactor Coolant Pump Testing Using Motor Current Signature Analysis." Framatome Technologies Inc.
  12. 김태종, 황상문, 박노길, 2000, "BLDC 전동기의 동적편심 및 전자기적 불평형력을 고려한 편심 회전자의 과도 동적해석," 한국소음진동학회지, Vol. 10, No. 3, pp. 401-409.