Gas Chromatographic Determination of Benfuresate through On-column Injection

On-column Injector를 이용한 benfuresate의 분석

  • Kwon, Jin-Wook (National Verterinary Research & Quarantine Service Busan Regional Office) ;
  • Kim, Kyun (Toxicology Research Center, Korea Research Institute of Chemical Technology) ;
  • Kim, Yong-Hwa (Toxicology Research Center, Korea Research Institute of Chemical Technology)
  • Published : 2002.06.01

Abstract

Benfuresate의 잔류분석을 위해 GC-FPD(S-mode)를 이용하여 분석조건을 설정 중 열적 불안정으로 인해 열분해 산물과 모 화합물이 혼재됨이 확인되었다. 가스크로마토그라프를 이용한 열분해의 주된 요인은 주입구의 온도와 주입구내의 기화 정도인 것으로 판단되었으며, 주입구를 Chauhan과 Debre 가 고안한 on-column으로 교체 후 분석한 결과 분해산물이 없는 단일 봉우리의 크로마토그램을 얻을 수 있었고, 절대량으로 0.6-4ng의 정량 범위 내에서 유의성 높은 검량선을 얻을 수 있는 주입구 온도는 20$0^{\circ}C$였다.

Keywords

References

  1. Anonymous Benfuresate-Herbicide, Technical Infomation. Schering A.G. Berlin 1991
  2. Erney DR, Gillespie AM, Gilvydis DM and Poole CF. Explanation of the matrix-induced chromatographic response enhancement of organophosphorus pesticides during open tubular column gas chroma-tography with splitless or hot on-column injection and flame photometric detection. J. Chromatogr. 1993; 638: 58-63
  3. Grob RL. Modem practice of gas chromatography 263. John Wiley & Sons, Inc. New York. 1977
  4. Horne SO and Van Hoohstraten SO. NC 20484; a new selective herbicide for control of Cyperus spp. and other weeds in cotton. Proc. Br. Crop Prot. Conf. - Weeds, 1980; 15(1): 201-208
  5. Jeninnings WG and Rapp A. Sample preparation for gas chromatographic analysis. cited Chanhan, J and A. Darbre (1981) HRC & CC 4 260.Dr. Alfred Huthig Verlag, New York. 1983
  6. Kleifield Y, Blumenfeld T, Herzlinger G and Bucsbaum H. Selective nutsedge control in cotton. Phytoparasitica 1992; 20(1): 37-46 https://doi.org/10.1007/BF02995633
  7. McMahon BM and Sawyer LD (Editor). Pesticide Analytical Manual, US Department of Health and Human Services, Food and Drug Administration, Washington, DC. 1987; Vol. 1 Section 314. 34
  8. Moat TF and Jenkins JJA. Gas chromatographic determination of air borne residues of azinphosmethyl and azinphosmethyl-oxon by cool on-column injection. J. Chromatogr. 1997; 775:307-312 https://doi.org/10.1016/S0021-9673(97)00294-X
  9. Park DS, Yang JE and Han DS. Assessment of the resi-dues of benfuresate and oxolinic acid in crops. Korean J. Environ. Agric. 1995; 14(3): 312-318
  10. Stan HJ and Goebel H. Evaluation of automated splitless and manual on-column injection techniques using capillary gas chroma-tography for pesticide residue analysis. J. Chromatogr. 1984; 314-413
  11. Stan HJ and Muller HM. Evaluation of automated and manual hot-splitless, cold-splitless (PTV), and on-column injecton technique using capillary gas chromatography for the analysis for organophosphorus pesticides. J. High Resolt. Chromatogr. Commun. 1988; 11: 140-143 https://doi.org/10.1002/jhrc.1240110136
  12. Yang JE, Park DS and Han DS. Comparative assessment of the half-lives of benfuresate and oxolinic acid estimated from kinetic models under field soil conditions. Korean J. Environ. Agric. 1995; 14(3): 302-311