DOI QR코드

DOI QR Code

COMPARISON OF APPROXIMATE MODELS FOR HIGH ENERGY COSMIC RADIATION SHIELDING CALCULATION

고에너지 우주방사선 차폐계산을 위한 근사모델 비교

  • 신명원 (경희대학교 원자력공학과) ;
  • 김명현 (경희대학교 원자력공학과)
  • Published : 2002.06.01

Abstract

Two approximate calculation models for a cosmic radiation shielding in satellite are compared with detailed 3-dimensional calculation results. One is a sectoring method and the other is a chord-length distribution method. Shielding caltulation is performed for KITSAT-1 under the assumed environment at SAA (South Atlantic Anomaly) location with AP-8 radiation spectrum model. When both approximate models are applied, calculation error is expected compared with 3-D detailed geometry calculation because of straight knock-on assumption neglecting the deflection of incident proton. However, both approximate models showed good agreements with 3-dimensional detailed Monte Carlo calculation in two dose detector locations.

인공위성에서의 우주방사선 차폐계산을 위한 근사계산 방법으로 sectoring method를 적용하는 방법과 chord-length 분포를 이용하는 방법을 상세 계산 결과와 비교하였다. 저 궤도 위성인 우리별 1호를 대상으로 양성자의 차폐계산을 수행하였다. 이때 방사선환경은 AP-8 model을 이용하여 구한 SAA(South Atlantic Anomaly)지역으로 가정하였다. Sectoring method와 chord-length 분포를 이용하는 방법은 양성자가 물질내에서 직진한다는 기본적인 가정을 사용하므로 3차원 상세계산 결과와 비교하여 어느 정도의 오차를 갖는다. 그러나 우리별 1호를 대상으로 수행된 계산 결과에서 두 계측기 위치에서의 피폭량 예측은 2가지 근사모델이 모두 상세계산 결과와 근사하게 일치하였다.

Keywords

References

  1. IEEE NSREC Short Courses Barth,J.
  2. Radiation and Shielding in Space Haffner,J.W.
  3. JA & SS v.18 Kim,S.J.;Shin,Y.H.;Min,K.W
  4. IEEE Short Courses Kinnison,J.D.
  5. Master Thesis, Kyung Hee University Lee,S.Y.
  6. User Guide to LCS:The Lahet Code System Prael,R.E.;Lichtenstein,H.
  7. CHARGE Code for Space Radiation Shielding Analysis Yucker,W.R.;Lilley,J.R.