Analysis of Medium Voltage Power-Line Channel Characteristics Considering the Skin Effect

표피효과를 고려한 중전압 전력선 채널특성 분석

  • Published : 2002.08.01

Abstract

In this paper, we analyzed a medium voltage power line characteristics considering the skin effect for high speed data transmission. Medium power-line characteristics impedance was obtained by the S-parameter method which is used in high frequency band. Power line channel characteristics was measured using it designed coupler, it is a wide band coupler between medium powe-line and measurement system. Attenuation characteristics along the frequency was decreased linearly when skin effect was considered but attenuation characteristics along the frequency was decreased linearly when skin effect was not considered. Impedance was showed lower and lower in proportional to frequency, and variation was decreased in proportional to frequency.

본 논문에서는 고속데이터 전송을 위한 중 전안 전력선로의 특성을 표피효과를 고려한 전송 파라메타로써 채널특성을 분석하였다. 중전압 통신 선로의 특성임피던스는 고주파 개념을 이용한 산란 계수법으로 구하였으며 광대역 특성을 갖는 결합기를 이용하여 0∼30MHz 주파수 대역에서 중전압 전력선의 채널특성을 측정하였다. 통신 선로의 표피효과를 고려하였을 경우 주파수에 대한 선로의 감쇠 특성은 선형적으로 감소하였으나 표피효과를 고려하지 않았을 경우에는 선로의 감쇠 특성은 급격히 감소함은 알 수가 있었다. 임피던스 특성은 주파수가 높을수록 임피던스 크기가 점점 낮아지며 변화량도 적어짐을 알 수가 있었다.

Keywords

References

  1. Christian Hensen, 'Data Transmission Application via Low Voltage Power lines OFDM Tecnnique,' IEEE Transactions on Power Delivery, Vol.9,no.2, April 1998. pp 210-214
  2. Dirk Galda and Hermann Rohling,' Narrowband Interference Reuction in OFDM-based Power line Communication Systems,' (ISPLC2001) pp 345-351
  3. E. Yavuz. F. Kural, N. Coban, B. Ercan and M. Safak, 'Modeling of Power lines for digitalCommunications,'(ISPLC2000) pp 161-168
  4. J. R. Nicholson and J. A. Malack, 'RF impedance of power-lines and line impedance stabilization networks in conducted interference measurements,' IEEE Trans. Electromagn. Compat., vol.1 EMC-15, no.2, pp. 84-86,May 1973
  5. P. J. Kwasniok, M.D. Bui, Kozlowski, and S. S. Stuchly, 'Technique for measurement of power line impedances in the frequency range from 500Khz to 500Mhz', IEEE Transactionsonelectromagnetic compatibility, vol. 35, No.1, Feb 1993
  6. Christian Hensen, Dr. Wolfgang Schulz, Sascha Schwarze, 'Characterisation, Measurement and Modeling of Medium Voltage Power-line cables for High Data Rate Communication,'(ISPLC '1998)
  7. Holger philipps.'Performance Measurements of Power line channels at high frequencies,'(PLC'98), March,1998, pp 229-237
  8. Manfred Zimmermann, Klaus Dostert, 'A Multipath Signal Propagation Model for the power line Channel in the High Frequence Range ,' (ISPLC '2000)
  9. R. M. Vines etal., “Noise on residential power distribution circuits,” IEEE Trans. Electromagn. Compat., vol.26, No.4, pp. 161-168, November 1984 https://doi.org/10.1109/TEMC.1984.304217
  10. Daniel W. DurbakOlaf, James R. Stewart, 'PLC Signal Attenuation in Branched Networks,' IEEE Transactions on Power delivery, Vol.5, No.2, April 1990 pp 878-882 https://doi.org/10.1109/61.53097
  11. M.S.Sarto,'Time-Domain Analysis of Electromagnetic Interference from Broband digital signal transmission on Finite-length Power Networks,' IEEE Transactions on Power Delivery, Vol.13,No.4 October 1998. pp 972-978 https://doi.org/10.1109/61.714411
  12. H.Y.Kwon, J.C.Park,and G.I.Shin, 'Analysis on Data Transmission Rate of very high speed Digital Subscriber Loops,' proc.1998 Int.wireless and Telecomm Symposium, KualaLumper, Malaysia,11-25 May,1998
  13. O.G.Houijen, 'A Channel Model for the Low Voltage Power-Line Channel Measurement and Simulation Results,' ISPLC '97, Essen, Germany, April 1997, pp 51-56
  14. J.W.Lechleider, 'Line analysis for digital subscriber Lines' IEEE Common., May, pp 25-32, Sept1989
  15. 박규홍, '전력전송공학' 동일출판사 pp.12-16, 2000.1월