The Evaluation and Investigation of Conscious Cognition Degree on a room-size air cleaner

실내용 공기청정기의 성능평가 및 인식도 조사

  • 손종렬 (고려대 보건대학 환경위생과) ;
  • 김영환 (고려대 보건대학 환경위생과) ;
  • 우완기 (장안대학 환경시스템과)
  • Published : 2002.09.01

Abstract

This study was performed on a questionnaire survey of 500 people about their awareness for indoor air pollution, and measured efficiency of air cleaner which can remove the CO and air-borne particulate of ETS(Environmental Tobacco Smoke) in air clean chamber. The room-size cleaner for measuring indoor air contaminants has been applied to evaluation of two different air cleaner such as the mechanic air cleaner with hepafilter(HPA) and the electrostatic air cleaner with metal plate. The measuring experiment was carried out in a chamber by sampling the air. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 38% of them can feel indoor air pollutions degrees directly by their sense of smell, For the installation of indoor pollution control equipment, 34% of all respondents installed air cleaner because of the problem of economical charge and almost respondents was not satisfied the trust of ability purified indoor air pollutants. In the experimental results, it was found that more than 95% of CD and air-borne particulate of ETS were removed within 20 minutes. The reaction kinetics of removal pollutants was verified as the pseudo-first order, Finally, it appeared that the room-sire air cleaner can be applied to new technology for removing indoor air contaminants.

Keywords

References

  1. 공기청정기술 v.8 no.2 공기청정기의 성능 시험 및 평가 오명도
  2. ASHRAE Handbook Air Cleaners for Praticulate Contaminants ASHRAE
  3. 일본산업규격, JIS C 9615 Air Cleaners
  4. 한국산업규격, KS C 9314 공기청정기
  5. 공기청정기술 v.11 no.2 공기청정기 시험법의 특성과 동향 유경훈
  6. 공기청정기술 v.11 no.2 공기청정기 산업현황 최철원
  7. 공기청정기술 v.11 no.2 실내형 공기청정기의 부유분진 제거효율평가 윤동원
  8. 공기청정기술 v.11 no.2 오명도
  9. '97 하계 학술발표회 논문집 동적 특성방법을 이용한 실내용 공기 청정기의 효율 평가 최석회
  10. 한국섬유공학회지 v.35 no.7 유소영(외 3명)
  11. 공기청정기술 21세기 공기청정기술의 발전동향 v.13 no.1 오명도
  12. 한국위생학회지 v.27 no.2 생활환경과 실내공기의 미생물학적 오염에 관한 연구 정윤희(외2명)
  13. ANSI/ASHARE standard Gravimetic and dust spot procedures for testing air cleaning devices uised in general ventilation for moving particulate matter, 521-1
  14. Aerosol Science and Technology v.22 Electrical agglomeration of aerosol particles in an alternating electric field Hautanen,J.;Kilpelainen,M.(etc.) https://doi.org/10.1080/02786829408959739
  15. Aersol science and Technology v.23 Experimental investigation for agglomeration of aerosols in alternating electric field Kideso,J.;Bhatia,V.K.;Lind,L.;Johnson,E.(etc.) https://doi.org/10.1080/02786829508965341